English
Related papers

Related papers: Sensitivity adjustable in-line high-temperature se…

200 papers

A spherical Fabry-Perot interferometer with adjustable mirror spacing is used to produce interference fringes with frequency separation (c/2L)/N, N=2-15. The conditions for observation of these fringes are derived from the consideration of…

Atomic Physics · Physics 2007-05-23 Katherine Kerner , Simon M. Rochester , Valeriy V. Yashchuk , D. Budker

The frequency stability of lasers is limited by thermal noise in state-of-the-art frequency references. Further improvement requires operation at cryogenic temperature. In this context, we investigate a fiber-based ring resonator. Our…

Optics · Physics 2021-01-22 Benjamin Merkel , Daniel Repp , Andreas Reiserer

Precise temperature measurement at micro/nanoscale is crucial across various domains including physical sciences, chemical processes, industrial production, medical diagnosis, weather forecasting, electronics, and biology. Micro/nanoscale…

Applied Physics · Physics 2025-03-25 Hassan Irshad Bhatti

Silicon's bandgap inherently restricts its photodetection to wavelengths below 1100 nm, necessitating the integration of costly III-V semiconductors for short-wave infrared applications. Hyperdoping silicon beyond the solid solubility limit…

A simple and low cost apparatus has been designed and built to measure the electrical resistivity, ($\rho$), of metal and semiconductors in 300-620 K temperature range. The present design is suitable to do measurement on rectangular bar…

General Physics · Physics 2017-04-14 Saurabh Singh , Sudhir K. Pandey

The precise measurement of low temperatures is a challenging, important and fundamental task for quantum science. In particular, in-situ thermometry is highly desirable for cold atomic systems due to their potential for quantum simulation.…

We present measurements of the low temperature thermal conductivity for materials useful in the construction of cryogenic supports for scientific instrumentation and in the fabrication of flat flexible cryogenic cabling. The materials we…

Instrumentation and Detectors · Physics 2019-01-11 M. Daal , N. Zobrist , N. Kellaris , B. Sadoulet , M. Robertson

Astrophysical observations suggest the existence of an unknown kind of matter in the Universe, in the frame of the $\Lambda$CDM model. The research field of dark matter covers an energy scale going from massive objects to ultra-light scalar…

Instrumentation and Methods for Astrophysics · Physics 2025-07-14 Yara Hariri , Jacques Millo , Clément Lacroûte , Joannès Barbarat , Yann Kersalé , Jonathan Gillot

Nickel silicide Schottky diodes formed on polycrystalline Si<P> films are proposed as temperature sensors of monolithic uncooled microbolometer IR focal plane arrays. Structure and composition of nickel silicide/polycrystalline silicon…

Materials Science · Physics 2013-04-23 K. V. Chizh , V. A. Chapnin , V. P. Kalinushkin , V. Ya. Resnik , M. S. Storozhevykh , V. A. Yuryev

We describe an apparatus for the implementation of hybrid optomechanical systems at 4 K. The platform is based on a high-finesse, micrometer-scale fiber Fabry-Perot cavity, which can be widely tuned using piezoelectric positioners. A…

A novel approach to calibrate the sensitivity of a differential thermometer, consisting of several thermocouples connected in series (thermopile), has been developed. The goal of this method is to increase the accuracy of small temperature…

Instrumentation and Detectors · Physics 2020-12-24 Tim Prangemeier , Iman Nejati , Andreas Müller , Philip Endres , Mario Fratzl , Mathias Dietzel

The study of protein functions attributed to the conformation and fluctuation that are ruled by both the amino acid sequence and thermodynamics, requires thermodynamic quantities given by calorimetry using thermometric techniques. The…

Biological Physics · Physics 2019-05-01 Manabu Ishino , Akio Kishigami , Hiroyuki Kudo , Jongsuck Bae , Tatsuo Nozokido

Fundamental sensitivity of an optical interferometric gravitational wave detector increases with increase of the optical power which, in turn, limited because of the opto-mechanical parametric instabilities of the interferometer. We propose…

General Relativity and Quantum Cosmology · Physics 2016-04-27 Andrey B. Matsko , Mikhail V. Poplavskiy , Hiroaki Yamamoto , Sergey P. Vyatchanin

Large Fabry-Perot Interferometers are used in a variety of astronomical instrumentation, including spectro-polarimeters for 4-meter class solar telescopes. In this work we comprehensively characterize the cavity of a prototype 150 mm…

Instrumentation and Methods for Astrophysics · Physics 2022-02-09 V. Greco , A. Sordini , G. Cauzzi , F. Cavallini , C. Del Vecchio , L. Giovannelli , F. Berrilli , D. Del Moro , K. Reardon , K. Pietraszewski

We describe the recent modifications to the data reduction technique for observations acquired with the scanning Fabry-Perot interferometer (FPI) mounted on the 6-m telescope of the Special Astrophysical Observatory that allow the…

Instrumentation and Methods for Astrophysics · Physics 2015-12-09 A. V. Moiseev

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are…

Instrumentation and Methods for Astrophysics · Physics 2026-02-05 Valentin Sauvage

This paper introduces a thermal infrared detector utilizing a nano-optomechanical silicon nitride (SiN) resonator, equipped with a free-space impedance-matched (FSIM) absorber composed of a platinum (Pt) thin film, offering a broadband…

Instrumentation and Detectors · Physics 2025-05-12 Paolo Martini , Stefan Emminger , Kostas Kanellopulos , Niklas Luhmann , Markus Piller , Robert Greyson West , Silvan Schmid

Optical spectroscopy of quantum materials at ultralow temperatures is rarely explored, yet it may provide critical characterizations of quantum phases not possible using other approaches. We describe the development of a novel experimental…

In this paper, the thermo-mechanical behaviour of hemp fibres (Cannabis sativa L.) is investigated using a Dynamic Mechanical Analyser. Experiments are performed at a frequency of 1 Hz in the temperature range of 20 to 220\degree C. When a…

Classical Physics · Physics 2009-06-22 Vincent Placet

Nanoscale thermometry is paramount to study primary processes of heat transfer in solids and is a subject of hot debate in cell biology. Here we report ultrafast temperature sensing using all-optical thermometry exploiting synthetic…

Applied Physics · Physics 2019-04-24 Sumin Choi , Viatcheslav N. Agafonov , Valery A. Davydov , Taras Plakhotnik