English
Related papers

Related papers: High-accuracy optical clocks with sensitivity to t…

200 papers

We carried out detailed high-precision study of Ag-like Nd$^{13+}$, Sm$^{15+}$ and In-like Ce$^{9+}$, Pr$^{10+}$, Nd$^{11+}$, Sm$^{13+}$, Eu$^{14+}$ highly-charged ions. These ions were identified to be of particular interest to the…

Atomic Physics · Physics 2015-06-22 M. S. Safronova , V. A. Dzuba , V. V. Flambaum , U. I. Safronova , S. G. Porsev , M. G. Kozlov

An ultrastable optical clock based on neutral atoms trapped in an optical lattice is proposed. Complete control over the light shift is achieved by employing the $5s^2 {}^1S_0 \to 5s5p {}^3P_0$ transition of ${}^{87}{\rm Sr}$ atoms as a…

Atomic Physics · Physics 2009-11-10 Hidetoshi Katori , Masao Takamoto , V. G. Pal'chikov , V. D. Ovsiannikov

It is shown that the dynamic differential scalar polarisability of the $S_{1/2}-D_{5/2}$ transition in $^{138}$Ba$^+$ can be determined to an inaccuracy below $0.5\%$ across a wide wavelength range ($\lambda>700\,\mathrm{nm}$). This can be…

Atomic Physics · Physics 2019-10-30 M. D. Barrett , K. J. Arnold , M. S. Safronova

The possibility of using neutral and double ionized erbium for atomic clocks of high precision is investigated. In both cases the narrow electric quadrupole clock transition between the ground and first exited state of the same…

Atomic Physics · Physics 2015-06-16 A. Kozlov , V. A. Dzuba , V. V. Flambaum

Optical lattice clocks with uncertainty and instability in the $10^{-17}$-range and below have so far been demonstrated exclusively using fermions. Here, we demonstrate a bosonic optical lattice clock with $3\times 10^{-18}$ instability and…

Demands from several areas of science and technology have lead to a worldwide search for accurate optical clocks with an uncertainty of 1 part in $10^{18}$, which is $10^{3}$ times more accurate than the present day cesium atomic clocks…

Atomic Physics · Physics 2017-08-23 Chiranjib Sur , K. V. P. Latha , Rajat K. Chaudhuri , B. P. Das , D. Mukherjee

In neutral atom optical clocks, the higher-order atomic polarizability terms lead to the clock transition frequency shift which is motion-state dependent and nonlinear with the optical lattice depth. We propose to use an auxiliary optical…

Atomic Physics · Physics 2024-02-06 Artem Golovizin

We report high-precision frequency ratio measurements between optical atomic clocks based on $^{27}$Al$^+$, $^{171}$Yb, and $^{87}$Sr. With total fractional uncertainties at or below $3.2 \times 10^{-18}$, these measurements meet an…

Multi-ion optical clocks offer the possibility of overcoming the low signal-to-noise ratio of single-ion clocks, while still providing low systematic uncertainties. We present simultaneous spectroscopy of up to four ${}^{115}$In${}^+$ clock…

Evidence that the fine structure constant, alpha, was different in an early epoch has recently been found in quasar (QSO) absorption spectra. An accurate laboratory measurement of alpha variation could help to distinguish between space and…

Atomic Physics · Physics 2016-09-08 E. J. Angstmann , V. A. Dzuba , V. V. Flambaum

Experiments aimed at searching for variations in the fine-structure constant $\alpha$ are based on spectroscopy of transitions in microscopic bound systems, such as atoms and ions, or resonances in optical cavities. The sensitivities of…

Atomic Physics · Physics 2023-05-22 Beata Zjawin , Marcin Bober , Roman Ciuryło , Daniel Lisak , Michał Zawada , Piotr Wcisło

We report an optical lattice clock with a total systematic uncertainty of $8.1 \times 10^{-19}$ in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultra-narrow…

Atomic Physics · Physics 2024-07-23 Alexander Aeppli , Kyungtae Kim , William Warfield , Marianna S. Safronova , Jun Ye

The singly-ionized lutetium has a number of fortuitous properties well suited for a design of an optical clock and corresponding applications. In this work, we study Lu+ properties relevant to a development of the clock using the…

Atomic Physics · Physics 2019-01-29 S. G. Porsev , U. I. Safronova , M. S. Safronova

Dependence of transition frequencies on the fine structure constant $\alpha=e^2/\hbar c$ is calculated for several many-electron systems which are used or planned to be used in the laboratory search for the time variation of the fine…

Atomic Physics · Physics 2009-11-13 V. A. Dzuba , V. V. Flambaum

We report on an evaluation of an optical clock that uses the $\phantom{}^2S_{1/2} \rightarrow \phantom{}^2D_{5/2}$ transition of a single $^{88}$Sr$^+$ ion as the reference. In contrast to previous work, we estimate the effective…

Our calculations have shown that the 5f_5/2-7s_1/2 23131 cm^{-1} transition from the ground state in the ion Th^{3+} is very sensitive to the temporal variation of the fine structure constant alpha (q=-75300 cm^{-1}). The line is very…

Atomic Physics · Physics 2010-04-29 V. V. Flambaum , S. G. Porsev

Highly charged ions (HCIs) combine compact electronic structure with strong relativistic effects, offering both robustness against external perturbations and enhanced sensitivity to variations of the fine-structure constant. Recent advances…

Atomic Physics · Physics 2026-02-17 S. G. Porsev , M. S. Safronova

We consider an application of precision frequency measurements to searches for possible time variations of the fundamental physical constants. Current laboratory constraints on variations of the fine structure constant alpha and other…

Atomic Physics · Physics 2007-05-23 Savely G. Karshenboim , Victor Flambaum , Ekkehard Peik

Despite being a canonical example of quantum mechanical perturbation theory, as well as one of the earliest observed spectroscopic shifts, the Stark effect contributes the largest source of uncertainty in a modern optical atomic clock…

Atomic Physics · Physics 2012-04-18 J. A. Sherman , N. D. Lemke , N. Hinkley , M. Pizzocaro , R. W. Fox , A. D. Ludlow , C. W. Oates

We report on a $^{88}$Sr$^{+}$ single-ion optical clock with an estimated fractional systematic uncertainty of $7.9\times 10^{-19}$. The low uncertainty is enabled by small rf losses, a thorough evaluation of the blackbody-radiation…

Atomic Physics · Physics 2025-10-02 T. Lindvall , T. Fordell , K. J. Hanhijärvi , M. Doležal , J. Rahm , S. Weyers , A. E. Wallin