Related papers: Aging suppression in Multistrip Multigap Resistive…
The Multigap Resistive Plate Chamber (MRPC) is a gaseous detector; the performance depends very much on the gas mixture as well as the design. MRPCs are used as a timing device in several collider experiments and cosmic ray experiments…
Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of…
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas…
The Multigap Resistive Plate Chambers (MRPC) are used as a timing detector in several particle physics and cosmic ray experiments. The gas mixture of MRPC at current experiments is a mixture containing $\rm C_2F_4H_2$ and in some cases $\rm…
Recent results of an aging test performed at the CERN Gamma Irradiation Facility on a single--gap RPC prototype developed for the LHCb Muon System are presented. The results are based on an accumulated charge of about 0.45 C/cm$^2$,…
This study demonstrates that the free-surface flow dynamics of dense piles of contactless silica microparticles depend on the resting period prior to flow. Microfluidic rotating drum experiments reveal that longer resting times lead to…
The low cost and high resolution Multi-gap Resistive Plate Chamber (MRPC) opens up a new possibility to find an efficient alternative detector for the Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the…
Large-size hybrid and pixelized GEM-Micromegas gaseous detectors (40x40 cm$^2$ active area) were developed and installed in 2014 and 2015 for the COMPASS2 physics program which started at the same time. That program involved in particular…
The incorporation of reconfigurable intelligent surface (RIS) into massive multiple-input-multiple-output (mMIMO) systems can unleash the potential of next-generation networks by improving the performance of user equipments (UEs) in service…
A new prototype of large area Multi-gap Resistive Plate Chamber (MRPC) with long readout strips was built. This Long-strip Multi-gap Resistive Plate Chamber (LMRPC) is double stacked and has ten 250 $\mu$m-thick gas gaps. Signals are read…
Aging effects in the relaxations of conductivity of a two-dimensional electron system in Si have been studied as a function of carrier density. They reveal an abrupt change in the nature of the glassy phase at the metal-insulator transition…
The mitigation of human-induced climate change is of crucial importance for the sustainability of humankind. For this aim the RPC community has exerted considerable effort over the last decade to reduce the emission of greenhouse gases from…
We consider the uplink of a hardware-impaired intelligent reflective surfaces (IRS) aided multi-cell massive multiple-input multiple-output (mMIMO) system with mobile user equipments, whose channel age with time. For this system, we analyze…
One of the on-going issues with the use of microchannel plates (MCP) in the ionization profile monitors (IPM) at Fermilab is the significant decrease in gain over time. There are several possible issues that can cause this. Historically,…
The ALICE Muon IDentifier is composed of 72 single-gap bakelite Resistive Plate Chambers, which have been operational since 2009 in maxi-avalanche mode (discrimination threshold:7 mV without amplification) with a…
The qualities of Physical Unclonable Functions (PUFs) suffer from several noticeable degradations due to silicon aging. In this paper, we investigate the long-term effects of silicon aging on PUFs derived from the start-up behavior of…
The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to…
Due to the beam related background, the inner chamber of BESIII MDC has aging effect after 5 years running. The gains of the inner chamber cells decrease obviously, and the max gain decrease is about 26% for the first layer cells. A new…
The phase-out of Hydrofluorocarbons (HFCs), due to their high Global Warming Potential (GWP), affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluorethane C2H2F4, has created operational difficulties on existing systems…
We report a systematic study of charge distribution dependency of CMS Resistive Plate Chamber (RPC) on gap thickness. Prototypes of double-gap RPCs with six different gap thickness ranging from from 1.0 to 2.0 mm in 0.2-mm steps have been…