The ATLAS Muon Spectrometer is undergoing a major upgrade for the High-Luminosity LHC (HL-LHC), including the addition of three new thin-gap Resistive Plate Chamber (RPC) layers in the inner barrel region. These RPCs have 1 mm gas gaps…
Numerical calculations have been performed to understand the reason for the observed non-uniform response of a Resistive Plate Chamber (RPC) in a few critical regions such as near edge spacers and corners of the device. In this context, the…
Multi-gap Resistive Plate Chambers (MRPCs) with multi-strip readout are considered to be the optimal detector candidate for the Time-of-Flight (ToF) wall in the Compressed Baryonic Matter (CBM) experiment. In the R&D phase MRPCs with…
Experiments performed in the last years demonstrated slow relaxations and aging in the conductance of a large variety of materials. Here, we present experimental and theoretical results for conductance relaxation and aging for the…
In this work we describe some recent results concerning the application of Resistive Plate Chambers operated in avalanche mode at atmospheric pressure for high-resolution time-of-flight measurements. A combination of multiple, mechanically…
We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-{\eta} RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap…
We have systematically studied the transmission of electrical signals along several 2-strip Resistive Plate Chambers (RPCs) in the frequency range $f=0.1-3.5$GHz. Such a range was chosen to fully cover the bandwidth associated to the very…
The ALICE (A Large Ion Collider Experiment) Time Projection Chamber (TPC) at CERN LHC is presently equipped with Multi Wire Proportional Chambers (MWPCs). A gating grid prevents ions produced during the gas amplification from moving into…
The development of gaseous detectors has been exciting again since the appearance of a MicroStrip Gas Chamber(MSGC) in 1988, which is made using a micro-electronics technology. These days lots of variations of the advanced gaseous detectors…
While in a triggered experiment the matching of the RPC transmission line impedance with the one of the front-end electronics is less critical, for a trigger-less data recording this becomes mandatory. As expected, impedance matching is not…
Micromegas detector is considered to be a promising candidate for a large variety of high-rate experiments. Micromegas of various geometries have already been established as appropriate for these experiments for their performances in terms…
Microcontrollers are increasingly present in embedded deployments and dependable systems, for which malfunctions due to hardware ageing can have severe impact. The lack of deployable techniques for ageing monitoring on these devices has…
Resistive Plate Chambers (RPCs) are essential active media of large-scale experiments as part of the muon systems and (semi-)digital hadron calorimeters. Among the several outstanding issues associated with the RPCs, the loss of efficiency…
Although the adverse effects of using power electronic conversion on the insulation systems used in different apparatuses have been investigated, they are limited to low slew rates and repetitions. These results cannot be used for…
We present an original design for large area gaseous detectors based on the MICROMEGAS technology. This technology incorporates an insulating grid, sandwiched between the micro-mesh and the anode-pad plane, which provides an uniform 200…
Micromegas technology is a promising candidate to replace Atlas forward muon chambers -tracking and trigger- for future HL-LHC upgrade of the experiment. The increase on background and pile-up event probability requires detector…
The standard gas mixture for the Resistive Plate Chambers (RPC), composed of C2H2F4/i-C4H10/SF6, allows the detector operation in avalanche mode, as required by the high-luminosity collider experiments. The gas density, the low current and…
Invited presentation at the 3rd International Conference on Detector Stability and Aging Phenomena in Gasous Detectors, this work summarizes the major outcomes of research on the processes of performance degradation of gaseous detectors on…
Usage of electrodes made of glass with low bulk resistivity seems to be a promising way to adapt the Resistive Plate Chambers (RPC) to the high-rate environment of the upcoming CBM experiment. A pilot four-gap RPC sample with electrodes…
A prototype of a single-gap glass Resistive Plate Chamber (RPC) is constructed by the authors. To find the considerations required for better operation of the detector's gas system, we have simulated the flow of the Ar gas through the…