English

Dielectric Resistive Plate Chamber as a detector for time-of-flight measurements

Instrumentation and Detectors 2007-05-23 v2

Abstract

Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of applied voltages. Double-gap DRPCs have demonstrated the MIP registration efficiency of 97% and the time resolution of 180-200 ps. No changes in DRPC operation have been observed with test beam intensities up to 10^3 Hz/cm^2.

Keywords

Cite

@article{arxiv.physics/0410103,
  title  = {Dielectric Resistive Plate Chamber as a detector for time-of-flight measurements},
  author = {A. Akindinov and V. Golovin and A. Martemiyanov and V. Petrov and A. Smirnitskiy and K. Voloshin},
  journal= {arXiv preprint arXiv:physics/0410103},
  year   = {2007}
}

Comments

8 pages, 7 figures text formatting and figures updated for better performance slight corrections made in the text