English
Related papers

Related papers: Dual-Energy Cone-Beam CT Using Two Complementary L…

200 papers

Purpose: Dual-energy CT (DECT) has been shown to derive stopping power ratio (SPR) map with higher accuracy than conventional single energy CT (SECT) by obtaining the energy dependence of photon interactions. However, DECT is not as widely…

Cone-beam CT (CBCT) provides on-board volumetric anatomy for image guidance and treatment adaptation in radiotherapy. To compensate for respiration-induced anatomical motion, time-resolved CBCT is highly desired to capture the…

Medical Physics · Physics 2025-11-05 Ruizhi Zuo , Hua-Chieh Shao , You Zhang

To obtain high-quality positron emission tomography (PET) scans while reducing radiation exposure to the human body, various approaches have been proposed to reconstruct standard-dose PET (SPET) images from low-dose PET (LPET) images. One…

Image and Video Processing · Electrical Eng. & Systems 2023-08-22 Zeyu Han , Yuhan Wang , Luping Zhou , Peng Wang , Binyu Yan , Jiliu Zhou , Yan Wang , Dinggang Shen

Four-dimensional Cone Beam Computed Tomography (4D-CBCT) has been developed to provide respiratory phase resolved volumetric imaging in image guided radiation therapy (IGRT). Inadequate number of projections in each phase bin results in low…

Medical Physics · Physics 2015-06-03 Xun Jia , Zhen Tian , Yifei Lou , Jan-Jakob Sonke , Steve B. Jiang

Cone-beam computed tomography (CBCT) is routinely collected during image-guided radiation therapy (IGRT) to provide updated patient anatomy information for cancer treatments. However, CBCT images often suffer from streaking artifacts and…

Computer Vision and Pattern Recognition · Computer Science 2023-11-02 Jiarui Zhu , Werxing Chen , Hongfei Sun , Shaohua Zhi , Jing Qin , Jing Cai , Ge Ren

Dual-energy computed tomography (DECT) is an advanced CT scanning technique enabling material characterization not possible with conventional CT scans. It allows the reconstruction of energy decay curves at each 3D image voxel, representing…

Image and Video Processing · Electrical Eng. & Systems 2022-02-01 Segolene Brivet , Faicel Chamroukhi , Mark Coates , Reza Forghani , Peter Savadjiev

Dual-energy X-ray Computed Tomography (DECT) constitutes an advanced technology which enables automatic decomposition of materials in clinical images without manual segmentation using the dependency of the X-ray linear attenuation with…

Image and Video Processing · Electrical Eng. & Systems 2025-07-25 Hang Xu , Alexandre Bousse , Alessandro Perelli

Cone-beam computed tomography (CBCT) systems, with their flexibility, present a promising avenue for direct point-of-care medical imaging, particularly in critical scenarios such as acute stroke assessment. However, the integration of CBCT…

Objective. Dual-energy computed tomography (DECT) has the potential to improve contrast, reduce artifacts and the ability to perform material decomposition in advanced imaging applications. The increased number or measurements results with…

Image and Video Processing · Electrical Eng. & Systems 2022-03-14 Alessandro Perelli , Suxer Alfonso Garcia , Alexandre Bousse , Jean-Pierre Tasu , Nikolaos Efthimiadis , Dimitris Visvikis

Objective: Cone-beam computed tomography (CBCT) provides a low-dose imaging alternative to conventional CT, but suffers from noise, scatter, and artifacts that degrade image quality. Synthetic CT (sCT) aims to translate CBCT to high-quality…

Medical Physics · Physics 2025-09-23 Alzahra Altalib , Chunhui Li , Alessandro Perelli

We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of…

Iodinated contrast media is essential for dual-energy computed tomography (DECT) angiography. Previous studies show that iodinated contrast media may cause side effects, and the interruption of the supply chain in 2022 led to a severe…

Image and Video Processing · Electrical Eng. & Systems 2023-08-28 Qing Lyu , Josh Tan , Megan E. Lipford , Chuang Niu , Micheal E. Zapadka , Christopher M. Lack , Jonathan D. Clemente , Christopher T. Whitlow , Ge Wang

Real-time cone-beam computed tomography (CBCT) provides instantaneous visualization of patient anatomy for image guidance, motion tracking, and online treatment adaptation in radiotherapy. While many real-time imaging and motion tracking…

Medical Physics · Physics 2024-09-27 Hua-Chieh Shao , Tielige Mengke , Tinsu Pan , You Zhang

The purpose of this study was to investigate the feasibility of extracting proton beams with two distinct energies within a single synchrotron cycle. The energy difference between the beams should be sufficient to use one beam as a range…

Accelerator Physics · Physics 2025-06-25 Alexander A. Pryanichnikov , Dmitry Shwartz , Jon Feldmand , Joao Seco , Maria Francesca Spadea

Many clinical applications depend critically on the accurate differentiation and classification of different types of materials in patient anatomy. This work introduces a unified framework for accurate nonlinear material decomposition and…

Medical Physics · Physics 2018-03-19 Wei Zhao , Don Vernekohl , Fei Han , Bin Han , Hao Peng , Lei Xing , James K Min

Detector-based spectral computed tomography is a recent dual-energy CT (DECT) technology that offers the possibility of obtaining spectral information. From this spectral data, different types of images can be derived, amongst others…

Image and Video Processing · Electrical Eng. & Systems 2022-10-10 Constantin Seibold , Matthias A. Fink , Charlotte Goos , Hans-Ulrich Kauczor , Heinz-Peter Schlemmer , Rainer Stiefelhagen , Jens Kleesiek

Industrial cone-beam X-ray computed tomography (CT) scans of additively manufactured components produce a 3D reconstruction from projection measurements acquired at multiple predetermined rotation angles of the component about a single…

Image and Video Processing · Electrical Eng. & Systems 2024-07-19 Jingsong Lin , Singanallur Venkatakrishnan , Gregery Buzzard , Amir Koushyar Ziabari , Charles Bouman

This paper focuses on minimizing the time requirement for CT capture through innovative simultaneous x-ray capture method. The state-of-the-art CT imaging methodology captures a sequence of projections during which the internal organ…

Medical Physics · Physics 2014-04-03 Sajib Saha , Murat Tahtali , Andrew Lambert , Mark Pickering

Computed tomography (CT) serves as an effective tool for lung cancer screening, diagnosis, treatment, and prognosis, providing a rich source of features to quantify temporal and spatial tumor changes. Nonetheless, the diversity of CT…

Image and Video Processing · Electrical Eng. & Systems 2023-10-10 Md Selim , Jie Zhang , Faraneh Fathi , Michael A. Brooks , Ge Wang , Guoqiang Yu , Jin Chen

The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain…

Medical Physics · Physics 2016-04-27 Wei Zhao , Don Vernekohl , Jun Zhu , Luyao Wang , Lei Xing