English
Related papers

Related papers: Self-supervised OCT Image Denoising with Slice-to-…

200 papers

Nosie is an important cause of low quality Optical coherence tomography (OCT) image. The neural network model based on Convolutional neural networks(CNNs) has demonstrated its excellent performance in image denoising. However, OCT image…

Image and Video Processing · Electrical Eng. & Systems 2022-05-03 Jie Du , Xujian Yang , Kecheng Jin , Xuanzheng Qi , Hu Chen

Optical coherence tomography (OCT) is a prevalent, interferometric, high-resolution imaging method with broad biomedical applications. Nonetheless, OCT images suffer from an artifact, called speckle which degrades the image quality. Digital…

In recent years, there has been a growing interest in applying convolutional neural networks (CNNs) to low-level vision tasks such as denoising and super-resolution. Due to the coherent nature of the image formation process, optical…

Computer Vision and Pattern Recognition · Computer Science 2019-01-29 Ashkan Abbasi , Amirhassan Monadjemi , Leyuan Fang , Hossein Rabbani , Yi Zhang

Recently, Self-supervised learning methods able to perform image denoising without ground truth labels have been proposed. These methods create low-quality images by adding random or Gaussian noise to images and then train a model for…

Image and Video Processing · Electrical Eng. & Systems 2021-04-07 Dongkyu Won , Euijin Jung , Sion An , Philip Chikontwe , Sang Hyun Park

Layer segmentation is important to quantitative analysis of retinal optical coherence tomography (OCT). Recently, deep learning based methods have been developed to automate this task and yield remarkable performance. However, due to the…

Image and Video Processing · Electrical Eng. & Systems 2023-12-07 Hong Liu , Dong Wei , Donghuan Lu , Xiaoying Tang , Liansheng Wang , Yefeng Zheng

We customize an end-to-end image compression framework for retina OCT images based on deep convolutional neural networks (CNNs). The customized compression scheme consists of three parts: data Preprocessing, compression CNNs, and…

Image and Video Processing · Electrical Eng. & Systems 2019-08-28 Pengfei Guo , Dawei Li , Xingde Li

In contrast to non-medical image denoising, where enhancing image clarity is the primary goal, medical image denoising warrants preservation of crucial features without introduction of new artifacts. However, many denoising methods that…

Image and Video Processing · Electrical Eng. & Systems 2024-12-02 Md. Touhidul Islam , Md. Abtahi M. Chowdhury , Sumaiya Salekin , Aye T. Maung , Akil A. Taki , Hafiz Imtiaz

In optical coherence tomography (OCT) volumes of retina, the sequential acquisition of the individual slices makes this modality prone to motion artifacts, misalignments between adjacent slices being the most noticeable. Any distortion in…

Machine Learning · Computer Science 2020-07-06 Yasmeen M. George , Suman Sedai , Bhavna J. Antony , Hiroshi Ishikawa , Gadi Wollstein , Joel S. Schuman , Rahil Garnavi

Medical imaging data suffers from the limited availability of annotation because annotating 3D medical data is a time-consuming and expensive task. Moreover, even if the annotation is available, supervised learning-based approaches suffer…

Image and Video Processing · Electrical Eng. & Systems 2020-11-12 Abinav Ravi Venkatakrishnan , Seong Tae Kim , Rami Eisawy , Franz Pfister , Nassir Navab

Optical Coherence Tomography (OCT) is essential for diagnosing conditions such as glaucoma, diabetic retinopathy, and age-related macular degeneration. Accurate retinal layer segmentation enables quantitative biomarkers critical for…

Image and Video Processing · Electrical Eng. & Systems 2025-09-10 S M Asiful Islam Saky , Ugyen Tshering

Supervised learning with a convolutional neural network is recognized as a powerful means of image restoration. However, most such methods have been designed for application to grayscale and/or color images; therefore, they have limited…

Image and Video Processing · Electrical Eng. & Systems 2019-07-02 Ryuji Imamura , Tatsuki Itasaka , Masahiro Okuda

Conventional Fourier-domain Optical Coherence Tomography (FD-OCT) systems depend on resampling into wavenumber (k) domain to extract the depth profile. This either necessitates additional hardware resources or amplifies the existing…

Optics · Physics 2025-09-24 Maryam Viqar , Erdem Sahin , Elena Stoykova , Violeta Madjarova

Optical neuroimaging is a vital tool for understanding the brain structure and the connection between regions and nuclei. However, the image noise introduced in the sample preparation and the imaging system hinders the extraction of the…

Image and Video Processing · Electrical Eng. & Systems 2021-09-23 Tianfang Zhu , Yue Guan , Anan Li

This paper presents a novel automated system that segments six sub-retinal layers from optical coherence tomography (OCT) image stacks of healthy patients and patients with diabetic macular edema (DME). First, each image in the OCT stack is…

Computer Vision and Pattern Recognition · Computer Science 2016-10-25 Sohini Roychowdhury , Dara D. Koozekanani , Michael Reinsbach , Keshab K. Parhi

Optical coherence tomography (OCT) is a medical imaging modality that allows us to probe deeper substructures of skin. The state-of-the-art wound care prediction and monitoring methods are based on visual evaluation and focus on surface…

Image and Video Processing · Electrical Eng. & Systems 2023-06-05 Prashant Kumar , Swatantra Dhara , Ayan Gope , Jyotirmoy Chatterjee , Subhamoy Mandal

Optical coherence tomography (OCT) can perform non-invasive high-resolution three-dimensional (3D) imaging and has been widely used in biomedical fields, while it is inevitably affected by coherence speckle noise which degrades OCT imaging…

Optics · Physics 2025-06-30 Renxiong Wu , Fei Zheng , Meixuan Li , Shaoyan Huang , Xin Ge , Linbo Liu , Yong Liu , Guangming Ni

In optical coherence tomography (OCT), axial resolution and signal-to-noise ratio (SNR) are typically viewed as uncoupled parameters. We show that this is only true for mirror-like surfaces, and that in diffuse scattering samples such as…

Optics · Physics 2022-04-06 Danielle J. Harper , Benjamin J. Vakoc

Ophthalmic images may contain identical-looking pathologies that can cause failure in automated techniques to distinguish different retinal degenerative diseases. Additionally, reliance on large annotated datasets and lack of knowledge…

Image and Video Processing · Electrical Eng. & Systems 2022-08-02 Sharif Amit Kamran , Khondker Fariha Hossain , Alireza Tavakkoli , Stewart Lee Zuckerbrod , Salah A. Baker

Optical Coherence Tomography (OCT) is a vital imaging modality for diagnosing and monitoring retinal diseases. However, OCT images are inherently degraded by speckle noise, which obscures fine details and hinders accurate interpretation.…

Computer Vision and Pattern Recognition · Computer Science 2025-09-15 Botond Fazekas , Thomas Pinetz , Guilherme Aresta , Taha Emre , Hrvoje Bogunovic

At the present time Optical Coherence Tomography (OCT) is among the most commonly used non-invasive imaging methods for the acquisition of large volumetric scans of human retinal tissues and vasculature. To resolve decisive information from…

Computer Vision and Pattern Recognition · Computer Science 2021-11-02 D. Sitenko , B. Boll , C. Schnörr