Related papers: Cryogenic resonant amplifier for electron-on-heliu…
Accurate in situ calibration of microwave attenuation and amplification-chain noise is essential for superconducting quantum circuits. We demonstrate a compact, self-calibrating cryogenic noise source based on an on-chip chromium attenuator…
We present the noise performance of High Electron Mobility Transistors (HEMT) developed by CNRS-C2N laboratory. Various HEMT's gate geometries with 2 pF to 230 pF input capacitance have been studied at 4 K. A model for both voltage and…
Ultralight bosonic dark matter with masses in the meV range, corresponding to terahertz (THz) Compton frequencies, remains largely unexplored due to the difficulty of achieving both efficient signal conversion and single-photon-sensitive…
Possible light bosonic dark matter interactions with the Standard Model photon have been searched by microwave resonant cavities. In this paper, we demonstrate the cryogenic readout system calibration of a 7.138 GHz copper cavity with a…
Current control techniques for cryogenically cooled qubits are realized with coaxial cables, posing multiple challenges in terms of cost, thermal load, size, and long-term scalability. Emerging approaches to tackle this issue include…
Broadband, energy-efficient signal transfer between cryogenic and room-temperature environment has been a major bottleneck for superconducting quantum and classical logic circuits. Photonic links promise to overcome this challenge by…
Cryogenic opto-electronic interconnects are gaining increasing interest as a means to control and read out cryogenic electronic components. The challenge is to achieve sufficient signal integrity with low heat load processing. In this…
We present measurements of the resonant microwave absorption by the Rydberg energy levels of surface state electrons on the surface of superfluid liquid helium, in the frequency range 165 - 220 GHz. The resonant frequency was strongly…
Single-photon terahertz (THz) detection is one of the most demanding technology for a variety of fields and could lead to many breakthroughs. Although its significant progress has been made in the last two decades, operating it at room…
In this dissertation, resonator-based readout techniques were developed for floating electrons as qubits on cryogenic substrates, using two platforms: electrons on liquid helium and electrons on solid neon. In addition, a cryogenic…
This paper reports the design and experimental characterization of a cryogenic compact low-power 60GHz amplifier for control of electron/hole spin qubits, as elementary building block for monolithic Si quantum processors. Tested at 2 K, the…
We present the measured baseline ionization resolution of a HEMT-based cryogenic charge amplifier coupled to a CDMS-II detector. The amplifier has been developed to allow massive semiconductor dark matter detectors to retain background…
We implemented a low noise current preamplifier for the readout of resistive bolometers. We tested the apparatus on thermometer resistances ranging from 10 Ohm to 500 Mohm. The use of current preamplifier overcomes constraints introduced by…
The challenges of operating qubits in a cryogenic environment point to a looming bottleneck for large-scale quantum processors, limited by the number of input-output connections. Classical processors solve this problem via multiplexing;…
Next-generation cryogenic transmission electron microscopes (TEM) aim to achieve high-resolution imaging at ultracold sample temperatures (< 90 K) and over extended hold times. Lower temperatures enable atomic-scale characterization with…
Microwave receivers using electromagnetically-induced transparency (EIT) in Rydberg atoms have recently demonstrated improved sensitivities. It is not evident how their state-of-the-art electric field sensitivities compare to those achieved…
A new cryogenic noise calibration source for radio astronomy receivers is presented. Dissipated power is only 4.2 mW, allowing it to be integrated with the cold part of the receiver. Measured long-term stability, sensitivity to bias…
The oscillating light axion field is known as wave dark matter. We propose an LC-resonance enhanced detection of the narrow band electric signals induced by the axion dark matter using a solenoid magnet facility. We provide full 3D…
The development of a microwave electrometer with inherent uncertainty approaching its ultimate limit carries both fundamental and technological significance. Recently, the Rydberg electrometer has garnered considerable attention due to its…
Quantum computing, ultra-low-noise sensing, and high-energy physics experiments often rely on superconducting circuits or semiconductor qubits and devices operating at deep cryogenic temperatures (4K and below). Photonic integrated circuits…