English
Related papers

Related papers: Towards robust PICOSEC Micromegas precise timing d…

200 papers

TORCH is a time-of-flight detector designed to perform particle identification over the momentum range 2$-$10 GeV/c for a 10 m flight path. The detector exploits prompt Cherenkov light produced by charged particles traversing a quartz plate…

We report experimental test-beam results on dielectric-loaded waveguide detectors that utilize microwave Cherenkov signals to time and characterize high energy particle showers. These results are used to validate models and produce…

Instrumentation and Detectors · Physics 2022-10-19 P. W. Gorham , C. Campos , C. Hast , K. Jobe , C. Miki , L. Nguyen , M. Olmedo , R. Prechelt , C. Sonoda , G. S. Varner

The concept and subsequent experimental verification of the proportionality between pulse amplitude and detector transit time for microchannel plate detectors is presented. This discovery has led to considerable improvement in the overall…

Quantum Physics · Physics 2009-11-13 Victor D. Irby

To meet the need for a high counting rate and high time resolution in future high-energy physics experiments, a prototype of a gas photodetector with an RPC structure was developed. Garfield++ simulated the detector's performance, and the…

Instrumentation and Detectors · Physics 2024-07-30 Yiding Zhao , D. Hu , M. Shao , Y. Zhou , S. Lv , Xiangqi Tian , Anqi Wang , Xueshen Lin , Hao Pang , Y. Suna

The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in Italy, will search for invisible decays of the hypothetical dark photon via the process $e^+e^-\rightarrow \gamma A'$, where the $A'$ escapes detection. The dark photon…

The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $\mu$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution…

A graphene-optimized silicon carbide PIN detector was fabricated and its radiation tolerance under X-ray irradiation of 160 keV was evaluated. Its electrical properties, charge collection performance and time resolution of beta-particles…

Instrumentation and Detectors · Physics 2026-04-23 Zhenyu Jiang , Congcong Wang , Jingxuan He , Yi Zhan , Yingjie Huang , Xiyuan Zhang , Xin Shi

In the readout electronics of the Water Cerenkov Detector Array (WCDA) in the Large High Altitude Air Shower Observatory (LHAASO), both high-resolution charge and time measurement are required over a dynamic range from 1 photoelectron…

Instrumentation and Detectors · Physics 2019-07-09 Cong Ma , Lei Zhao , Ruoshi Dong , Zouyi Jiang , Shaoping Chu , Xingshun Gao , Shubin Liu , Qi An

Swift, high resolution CMOS pixel sensors are being developed for the ILC vertex detector, aiming to allow approaching the interaction point very closely. A major issue is the time resolution of the sensors needed to deal with the high…

Dedicated R&D efforts are currently underway to couple a thin Cherenkov radiator to Silicon Photomultiplier (SiPM) arrays for precise charged particle Time-of-Flight (ToF) measurements. The prompt nature of Cherenkov radiation makes it an…

Instrumentation and Detectors · Physics 2026-01-22 M. N. Mazziotta , A. Di Mauro , M. Giliberti , A. Liguori , L. Lorusso , E. Nappi , N. Nicassio , G. Panzarini , R. Pillera , G. Volpe

Multi-gap RPC prototypes with readout on a multi-strip electrode were developed for the small polar angle region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The prototypes are based on low…

Due to their very fast signal rise time in the order of 1 ns, Silicon-Photomultipliers have become of increasing interest for many experiments that require very good timing resolution. With the prospect of an application in medical imaging…

Instrumentation and Detectors · Physics 2019-05-01 Reimund Bayerlein , Ivor Fleck , Todd Peterson , Albert H. Walenta

The time resolution of the second monolithic silicon pixel prototype produced for the MONOLITH H2020 ERC Advanced project was studied using a femtosecond laser. The ASIC contains a matrix of hexagonal pixels with 100 {\mu}m pitch, readout…

We describe the construction and calibration of a multi-channel liquid time projection chamber filled with Tetramethylsilane (TMS). Its charge readout system consists of 8 wires each in the $X$ and $Y$ directions. The chamber is also…

Instrumentation and Detectors · Physics 2020-06-03 Shuoxing Wu , Brian Lenardo , Manuel Weber , Giorgio Gratta

The phase 1 upgrade of the CMS pixel detector has been designed to maintain the tracking performance at instantaneous luminosities of $2 \times 10^{34} \mathrm{~cm}^{-2} \mathrm{~s}^{-1}$. Both barrel and endcap disk systems now feature one…

Instrumentation and Detectors · Physics 2018-07-25 Jory Sonneveld

The performance of the CMS electromagnetic calorimeter upgraded readout electronics, developed for the High-Luminosity phase of the LHC, is discussed. Data collected in two beam test campaigns conducted in 2018 and 2021 at the H4 and H2…

Instrumentation and Detectors · Physics 2025-11-24 The CMS Electromagnetic Calorimeter Group

We present new developments, based on beam tests and cosmic rays, on the gaseous photomultiplier (GasPM). The GasPM detects photons by combining a photocathode with a resistive-plate-chamber avalanche. It achieves $\mathcal{O}$(10) ps time…

Instrumentation and Detectors · Physics 2026-05-25 Simone Garnero , Kenji Inami , Kodai Matsuoka , Ryogo Okubo , Koichi Ueda

A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array…

Instrumentation and Detectors · Physics 2015-06-03 L. Gruber , G. S. M. Ahmed , S. E. Brunner , P. Bühler , J. Marton , K. Suzuki

A micro time-projection-chamber (micro-TPC) with a detection volume of 23*28*31 cm^3 was developed, and its fundamental performance was examined. The micro-TPC consists of a micro pixel chamber with a detection area of 31*31 cm^2 as a…

We study the possibility to use the Cherenkov light for the efficient detection of 511 keV photons with the goal to use it in TOF-PET. We designed and tested two detection modules consisting of PbF$_2$ crystals attached to Planacon MCP-PMT…

Instrumentation and Detectors · Physics 2020-03-24 C. Canot , M. Alokhina , P. Abbon , J. P. Bard , D. Breton , E. Delagnes , J. Maalmi , G. Tauzin , D. Yvon , V. Sharyy
‹ Prev 1 4 5 6 7 8 10 Next ›