English
Related papers

Related papers: Development of a timing chip prototype in 110 nm C…

200 papers

The existing ATLAS Tracker will be at its functional limit for particle fluences of 10^15 neq/cm^2 (LHC). Thus for the upgrades at smaller radii like in the case of the planned Insertable B-Layer (IBL) and for increased LHC luminosities…

The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical…

Instrumentation and Detectors · Physics 2020-12-29 The Tracker Group of the CMS Collaboration

It is foreseen to significantly increase the luminosity of the LHC in order to harvest the maximum physics potential. Especially the Phase-II-Upgrade foreseen for 2023 will mean unprecedented radiation levels, significantly beyond the…

Instrumentation and Detectors · Physics 2019-10-15 Marco Mandurrino

The Pixel Luminosity Telescope is a silicon pixel detector dedicated to luminosity measurement at the CMS experiment at the LHC. It is located approximately 1.75 m from the interaction point and arranged into 16 "telescopes", with eight…

Instrumentation and Detectors · Physics 2023-08-02 Paul Lujan

With the ultimate goal of developing a pixel-based readout for a TPC at the ILC, a GridPix readout system consisting of one Timepix3 chip with an integrated amplification grid was embedded in a prototype detector. The performance was…

Pixel detectors are used in the innermost part of multi purpose experiments at the Large Hadron Collider (LHC) and are therefore exposed to the highest fluences of ionising radiation, which in this part of the detectors consists mainly of…

Instrumentation and Detectors · Physics 2010-01-21 T. Rohe , J. Acosta , A. Bean , S. Dambach , W. Erdmann , U. Langenegger , C. Martin , B. Meier , V. Radicci , J. Sibille , P. Trueb

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Instrumentation and Detectors · Physics 2016-04-19 J. W. Zhao , B. H. Sun , I. Tanihata , S. Terashima , L. H. Zhu , A. Enomoto , D. Nagae , T. Nishimura , S. Omika , A. Ozawa , Y. Takeuchi , T. Yamaguchi

The Low Gain Avalanche Diodes (LGADs) are promising particle detectors for timing resolution better than $50$ ps under a high radiation environment. This study investigates n-in-p LGAD architecture, focusing on ultra-thin sensors of…

Instrumentation and Detectors · Physics 2026-01-26 Jaideep Kalani , Saptarshi Datta , Ganesh J Tambve , Prabhakar Palni

The tracking detector of ATLAS, one of the experiments at the Large Hadron Collider (LHC), will be upgraded in 2024-2026 to cope with the challenging environment conditions of the High Luminosity LHC (HL-LHC). The LPNHE, in collaboration…

The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of…

Instrumentation and Detectors · Physics 2021-04-28 B. Acar , G. Adamov , C. Adloff , S. Afanasiev , N. Akchurin , B. Akgün , M. Alhusseini , J. Alison , G. Altopp , M. Alyari , S. An , S. Anagul , I. Andreev , M. Andrews , P. Aspell , I. A. Atakisi , O. Bach , A. Baden , G. Bakas , A. Bakshi , P. Bargassa , D. Barney , E. Becheva , P. Behera , A. Belloni , T. Bergauer , M. Besancon , S. Bhattacharya , S. Bhattacharya , D. Bhowmik , P. Bloch , A. Bodek , M. Bonanomi , A. Bonnemaison , S. Bonomally , J. Borg , F. Bouyjou , D. Braga , J. Brashear , E. Brondolin , P. Bryant , J. Bueghly , B. Bilki , B. Burkle , A. Butler-Nalin , S. Callier , D. Calvet , X. Cao , B. Caraway , S. Caregari , L. Ceard , Y. C. Cekmecelioglu , G. Cerminara , N. Charitonidis , R. Chatterjee , Y. M. Chen , Z. Chen , K. y. Cheng , S. Chernichenko , H. Cheung , C. H. Chien , S. Choudhury , D. Čoko , G. Collura , F. Couderc , I. Dumanoglu , D. Dannheim , P. Dauncey , A. David , G. Davies , E. Day , P. DeBarbaro , F. De Guio , C. de La Taille , M. De Silva , P. Debbins , E. Delagnes , J. M. Deltoro , G. Derylo , P. G. Dias de Almeida , D. Diaz , P. Dinaucourt , J. Dittmann , M. Dragicevic , S. Dugad , V. Dutta , S. Dutta , J. Eckdahl , T. K. Edberg , M. El Berni , S. C. Eno , Yu. Ershov , P. Everaerts , S. Extier , F. Fahim , C. Fallon , B. A. Fontana Santos Alves , E. Frahm , G. Franzoni , J. Freeman , T. French , E. Gurpinar Guler , Y. Guler , M. Gagnan , P. Gandhi , S. Ganjour , A. Garcia-Bellido , Z. Gecse , Y. Geerebaert , H. Gerwig , O. Gevin , W. Gilbert , A. Gilbert , K. Gill , C. Gingu , S. Gninenko , A. Golunov , I. Golutvin , T. Gonzalez , N. Gorbounov , L. Gouskos , Y. Gu , F. Guilloux , E. Gülmez , M. Hammer , A. Harilal , K. Hatakeyama , A. Heering , V. Hegde , U. Heintz , V. Hinger , N. Hinton , J. Hirschauer , J. Hoff , W. S. Hou , C. Isik , J. Incandela , S. Jain , H. R. Jheng , U. Joshi , O. Kara , V. Kachanov , A. Kalinin , R. Kameshwar , A. Kaminskiy , A. Karneyeu , O. Kaya , M. Kaya , A. Khukhunaishvili , S. Kim , K. Koetz , T. Kolberg , A. Kristić , M. Krohn , K. Krüger , N. Kulagin , S. Kulis , S. Kunori , C. M. Kuo , V. Kuryatkov , S. Kyre , O. K. Köseyan , Y. Lai , K. Lamichhane , G. Landsberg , J. Langford , M. Y. Lee , A. Levin , A. Li , B. Li , J. -H. Li , H. Liao , D. Lincoln , L. Linssen , R. Lipton , Y. Liu , A. Lobanov , R. S. Lu , I. Lysova , A. M. Magnan , F. Magniette , A. A. Maier , A. Malakhov , I. Mandjavize , M. Mannelli , J. Mans , A. Marchioro , A. Martelli , P. Masterson , B. Meng , T. Mengke , A. Mestvirishvili , I. Mirza , S. Moccia , I. Morrissey , T. Mudholkar , J. Musić , I. Musienko , S. Nabili , A. Nagar , A. Nikitenko , D. Noonan , M. Noy , K. Nurdan , C. Ochando , B. Odegard , N. Odell , Y. Onel , W. Ortez , J. Ozegović , L. Pacheco Rodriguez , E. Paganis , D. Pagenkopf , V. Palladino , S. Pandey , F. Pantaleo , C. Papageorgakis , I. Papakrivopoulos , J. Parshook , N. Pastika , M. Paulini , P. Paulitsch , T. Peltola , R. Pereira Gomes , H. Perkins , P. Petiot , F. Pitters , F. Pitters , H. Prosper , M. Prvan , I. Puljak , T. Quast , R. Quinn , M. Quinnan , K. Rapacz , L. Raux , G. Reichenbach , M. Reinecke , M. Revering , A. Rodriguez , T. Romanteau , A. Rose , M. Rovere , A. Roy , P. Rubinov , R. Rusack , A. E. Simsek , U. Sozbilir , O. M. Sahin , A. Sanchez , R. Saradhy , T. Sarkar , M. A. Sarkisla , J. B. Sauvan , I. Schmidt , M. Schmitt , E. Scott , C. Seez , F. Sefkow , S. Sharma , I. Shein , A. Shenai , R. Shukla , E. Sicking , P. Sieberer , Y. Sirois , V. Smirnov , E. Spencer , A. Steen , J. Strait , T. Strebler , N. Strobbe , J. W. Su , E. Sukhov , L. Sun , M. Sun , C. Syal , B. Tali , U. G. Tok , A. Kayis Topaksu , C. L. Tan , I. Tastan , T. Tatli , R. Thaus , S. Tekten , D. Thienpont , T. Pierre-Emile , E. Tiras , M. Titov , D. Tlisov , J. Troska , Z. Tsamalaidze , G. Tsipolitis , A. Tsirou , N. Tyurin , S. Undleeb , D. Urbanski , V. Ustinov , A. Uzunian , M. van de Klundert , J. Varela , M. Velasco , M. Vicente Barreto Pinto , P. M. da Silva , T. Virdee , R. Vizinho de Oliveira , J. Voelker , E. Voirin , Z. Wang , X. Wang , F. Wang , M. Wayne , S. N. Webb , M. Weinberg , A. Whitbeck , D. White , R. Wickwire , J. S. Wilson , H. Y. Wu , L. Wu , C. H Yeh , R. Yohay , G. B. Yu , S. S. Yu , D. Yu , F. Yumiceva , A. Zacharopoulou , N. Zamiatin , A. Zarubin , S. Zenz , H. Zhang , J. Zhang

Low-Gain Avalanche Diode (LGAD) sensors, offering timing resolutions of the order of tens of picoseconds, are being widely adopted in particle physics experiments and related applications. As these applications scale to large numbers of…

Instrumentation and Detectors · Physics 2026-05-27 Kyungmin Lee , Hoyong Jeong , Junho Kim , Seokhyeon Lee , Jaebak Kim , Jae Hyeok Yoo

The Compact Muon Solenoid (CMS) detector at the CERN Large Hadron Collider (LHC) is undergoing an extensive Phase II upgrade program to prepare for the challenging conditions of the High-Luminosity LHC (HL-LHC). A new timing layer is…

Instrumentation and Detectors · Physics 2018-10-02 Irene Dutta

We have developed two radiation-hard ASICs for optical data transmission in the ATLAS pixel detector at the LHC at CERN: a driver chip for a Vertical Cavity Surface Emitting Laser (VCSEL) diode for 80 Mbit/s data transmission from the…

We present the architecture, design and first test results of SPIDER, the first prototype of a TSMC CMOS 65 nm ASIC designed for the time measurement path of LHCb Electromagnetic Calorimeter after LS4 Upgrade. The main requirements for the…

Low Gain Avalanche Detectors (LGADs) are silicon semiconductor sensors with an implanted thin p-doped multiplication layer that is designed to provide low gain. Most importantly, LGADs are specifically engineered to provide excellent…

Instrumentation and Detectors · Physics 2023-10-11 R. Moriya , R. Bates , M. Bullough , N. Cooke , A. Docheva , L. Lombigit , D. Maneuski , R. McFeely , N. Moffat

The concept of capacitive coupling between sensors and readout chips is under study for the vertex detector at the proposed high-energy CLIC electron positron collider. The CLICpix Capacitively Coupled Pixel Detector (C3PD) is an active…

Instrumentation and Detectors · Physics 2017-10-06 I. Kremastiotis , R. Ballabriga , M. Campbell , D. Dannheim , A. Fiergolski , D. Hynds , S. Kulis , I. Peric

The Large Hadron Collider (LHC) at CERN will undergo major upgrades to increase the instantaneous luminosity up to 5-7.5$\times10^{34}$ cm$^{-2}$s$^{-1}$. This High Luminosity upgrade of the LHC (HL-LHC) will deliver a total of 3000-4000…

Instrumentation and Detectors · Physics 2023-03-08 The Tracker Group of the CMS Collaboration

Deep sub micron HV-CMOS processes offer the opportunity for sensors built by industry standard techniques while being HV tolerant, making them good candidates for drift-based, fast collecting, thus radiation-hard pixel detectors. For the…

Instrumentation and Detectors · Physics 2016-09-21 Branislav Ristic

A new type of Time Projection Chamber (TPC) has been proposed for the upgrade of the ALICE (A Large Ion Collider Experiment at CERN) so as to cater to the high luminosity environment expected at the Large Hadron Collider (LHC) facility in…

Instrumentation and Detectors · Physics 2015-11-17 Saikat Biswas

Pixel detectors for precise particle tracking in high energy physics have been developed to a level of maturity during the past decade. Three of the LHC detectors will use vertex detectors close to the interaction point based on the hybrid…

Instrumentation and Detectors · Physics 2007-05-23 Norbert Wermes
‹ Prev 1 8 9 10 Next ›