English
Related papers

Related papers: Simulation of angular resolution of a new electrom…

200 papers

We examine three dense high-Z scintillating crystals for the $\mu \to e$ conversion experiment using the GEANT4 simulation toolkit. The full energy deposition, albedo, and longitudinal and lateral energy leakages for all crystal assemblies…

Instrumentation and Detectors · Physics 2012-12-19 Zafar Usubov

A spaghetti calorimeter (SPACAL) prototype with scintillating crystal fibres was assembled and tested with electron beams of energy from 1 to 5 GeV. The prototype comprised radiation-hard Cerium-doped Gd$_3$Al$_2$Ga$_3$O$_{12}$ (GAGG:Ce)…

This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The…

Instrumentation and Detectors · Physics 2018-09-13 CALICE Collaboration , J. Repond , L. Xia , J. Apostolakis , G. Folger , V. Ivantchenko , A. Ribon , V. Uzhinskiy , D. Boumediene , V. Francais , G. C. Blazey , A. Dyshkant , K. Francis , V. Zutshi , O. Bach , E. Brianne , A. Ebrahimi , K. Gadow , P. Gttlicher , O. Hartbrich F. Krivan , K. Krüger , J. Kvasnicka , S. Lu , C. Neubüser , A. Provenza , M. Reinecke , F. Sefkow , S. Schuwalow , Y. Sudo , H. L. Tran , P. Buhmann , E. Garutti , S. Laurien , D. Lomidze , M. Matysek , A. Kaplan , H. -Ch. Schultz-Coulon , G. W. Wilson , D. Jeans , K. Kawagoe , I. Sekiya , T. Suehara , H. Yamashiro , T. Yoshioka , M. Wing , K. Kotera , M. Nishiyama , T. Sakuma , T. Takeshita , S. Tozuka , T. Tubokawa , S. Uozumi , E. Calvo Alamillo , M. C. Fouz , J. Marin , J. Navarrete , J. Puerta Pelayo , A. Verdugo , M. Chadeeva , M. Danilov , A. Drutskoy , E. Popova , V. Rusinov , E. Tarkovsky , L. Emberger , M. Gabriel , C. Graf , Y. Israeli , N. van der Kolk , F. Simon , M. Szalay , H. Windel , S. Bilokin J. Bonis , R. Pöschl , A. Irles , A. Thiebault , F. Richard , D. Zerwas , M. Anduze , V. Balagura , E. Becheva , V. Boudry , J-C. Brient , R. Cornat , E. Edy , M. Frotin F. Gastaldi , B. Li , F. Magniette , J. Nanni , M. Rubio-Roy , K. Shpak , T. H. Tran , H. Videau , J. Cvach , M. Janata , M. Kovalcuk , I. Polak , J. Smolik , V. Vrba , J. Zalesak , J. Zuklin , S. Chang , A. Khan , D. H. Kim , D. J. Kong , Y. D. Oh , A. Elkhalii , M. Götze , C. Zeitnitz

Ahigh-granularity scintillator calorimeter readout with silicon photomultipliers (SiPMs) is an electromagnetic calorimeter (ECAL) candidate for experiments at the Circular Electron Positron Collider (CEPC). A critical design parameter of…

Instrumentation and Detectors · Physics 2021-12-22 Yazhou Niu

A high sensitivity Cardiac SPECT system using curved crystals with pinhole collimation was proposed previously (Dey, IEEE TNS 2012, Bhusal et al, Med. Phys. 2019). Here, we hypothesize that a high curvature hemi-ellipsoid detector results…

Instrumentation and Detectors · Physics 2022-05-24 Hanif R. Soysal , J. Dey , W. P. Donahue , K. L. Matthews

Highly collimated betatron radiation from a laser wakefield accelerator is a promising tool for spectroscopic measurements. Therefore there is a requirement to create spectrometers suited to the unique properties of such a source. We…

High density electromagnetic sandwich calorimeters with high readout granularity are considered for many future collider and fix-target experiments. Optimization of the calorimeter structure from the point of view of the electromagnetic…

High Energy Physics - Experiment · Physics 2024-10-01 Oleksandr Borysov , Shan Huang , Kamil Zembaczyński , Aleksander Filip Żarnecki

We simulate angular resolved RABBITT (Reconstruction of Attosecond Beating By Interference of Two-photon Transitions) measurements on valence shells of noble gas atoms (Ne, Ar, Kr, and Xe). Our non-perturbative numerical simulation is based…

Atomic Physics · Physics 2018-06-13 Alexander W. Bray , Faiza Naseem , Anatoli S. Kheifets

A prototype Scintillator-Tungsten electromagnetic calorimeter (ScECAL) for the ILC detector was tested in 2008 at the Fermilab test beam. Data were collected with electron, pion and muon beams in the energy range 1 to 32GeV combined with…

Instrumentation and Detectors · Physics 2010-07-16 Adil Khan

A rather new approach employing Monte Carlo GEANT simulation for converting the experimentally measured fold distribution to angular momentum distribution has been described. The technique has been successfully utilized to measure the…

Nuclear Experiment · Physics 2010-11-22 Deepak Pandit , S. Mukhopadhyay , Srijit Bhattacharya , Surajit Pal , A. De , S. R. Banerjee

The precise measurement of photon or electron impact position is the prerequisite to reconstruct the origin of two photons events from decay of {\pi}0 and {\eta} mesons or the di-electron channel from quarkonia decay. To facilitate such a…

Instrumentation and Detectors · Physics 2018-08-23 Wang Hongkai , Wang Liang , Han Jingru , Zhao Chunqi , Zuo Jiaxu , Zhang Chunhui

A version of Geant4 has been developed to treat high-energy proton radiography. This article presents the results of calculations simulating the effects of nuclear elastic scattering for various test step wedges. Comparisons with…

Instrumentation and Detectors · Physics 2014-09-19 Xu Haibo , Zheng Na

We performed a Geant4 simulation study on showers generated by electrons and hadrons in a large homogeneous calorimeter. We found that the energy deposit can be expressed as a linear function of the track length. The line does not pass…

Instrumentation and Detectors · Physics 2020-10-16 R. Terada , Y. Hasegawa , T. Takeshita

We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that is based on plastic scintillator tiles readout with silicon photomultipliers. In this work, we concretize its design by characterizing its…

Instrumentation and Detectors · Physics 2023-05-30 Miguel Arratia , Luis Garabito Ruiz , Jiajun Huang , Sebouh J. Paul , Sean Preins , Miguel Rodriguez

The CALICE prototype for a Si/W electromagnetic calorimeter has been tested in large scale test beams. Several million events with electrons and hadrons of different energies and impact angles have been recorded. The energy resolution has…

Instrumentation and Detectors · Physics 2009-02-19 Marcel Reinhard

The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of…

A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the detector, and the purpose of the present…

Instrumentation and Detectors · Physics 2021-01-21 Erik Fredenberg , Mats Lundqvist , Bjorn Cederstrom , Magnus Aslund , Mats Danielsson

A general approach to a fast simulation of electromagnetic showers using parameterizations of the longitudinal and radial profiles in homogeneous and sampling calorimeters is described. The dependence of the shower development on the…

High Energy Physics - Experiment · Physics 2007-05-23 G. Grindhammer , S. Peters

A prototype of the MeV gamma-ray imaging camera based on the full reconstruction of the Compton process has been developed. This camera consists of a micro-TPC that is a gaseous Time Projection Chamber (TPC) and scintillation cameras. With…

We design a GeV gamma ray detector based on an electron-positron pair measurement by using the BESS-polar magnet and study it with the GEANT4 simulation code. We consider an additional counter to select an electron-positron pair for which…

High Energy Astrophysical Phenomena · Physics 2010-10-07 S. Osone