Related papers: Simulation of angular resolution of a new electrom…
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed,…
A new method called Neighbor Cell Deposited Energy Ratio (NCDER) is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL).This method was applied to reconstruct the ECAL…
A module of the ATLAS electromagnetic barrel liquid argon calorimeter was exposed to the CERN electron test-beam at the H8 beam line upgraded for precision momentum measurement. The available energies of the electron beam ranged from 10 to…
The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons…
We describe an algorithm which has been developed to extract fine granularity information from an electromagnetic calorimeter with strip-based readout. Such a calorimeter, based on scintillator strips, is being developed to apply particle…
The RADiCAL Collaboration is conducting R\&D on high performance electromagnetic (EM) calorimetry to address the challenges expected in future collider experiments under conditions of high luminosity and/or high irradiation (FCC-ee, FCC-hh…
The performance of prototypes for the ALICE electromagnetic sampling calorimeter has been studied in test beam measurements at FNAL and CERN. A $4\times4$ array of final design modules showed an energy resolution of about 11%…
In the years between 2000 and 2002 several pre-series and series modules of the ATLAS EM barrel and end-cap calorimeter were exposed to electron, photon and pion beams. The performance of the calorimeter with respect to its finely segmented…
A simulation study of energy resolution, position resolution, and $\pi^0$-$\gamma$ separation using multivariate methods of a sampling calorimeter is presented. As a realistic example, the geometry of the calorimeter is taken from the…
A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams of electrons with energies between 20 and 150 GeV, produced…
Shashlyk electromagnetic calorimeter modules with an energy resolution of about 3%/sqrt{E (GeV)} for 50-1000 MeV photons has been developed, and a prototype tested. Details of these improved modules, including mechanical construction,…
A compact and fast electromagnetic calorimeter prototype was designed, built, and tested in preparation for a next-generation, high-rate muon g-2 experiment. It uses a simple assembly procedure: alternating layers of 0.5-mm-thick tungsten…
The scintillating properties of active materials used in high energy and particle physics experiments play an important role regarding the performances of both calorimeters and experiments. Two scintillator materials, a scintillating glass…
Next-generation high-energy electron-positron colliders, operating as Higgs factories, require an unprecedented jet energy resolution for precision measurements of Higgs and Z/W bosons. To address this challenge, a conceptual design is…
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a…
The Monte Carlo calculations of the Moliere radius (RM) for some homogeneous and heterogeneous media used in electromagnetic calorimetry in the energy range from 50 MeV to 10 GeV are presented in detail. The obtained results, the…
In order to better understand energy estimation of electromagnetic showers in segmented calorimeters, detailed Geant4 simulation studies of electromagnetic showers in the energy range 1--100 GeV in CsI have been performed. When sampled in…
A calorimetric detector for minimally disruptive measurements of atomic hydrogen beams is described. The calorimeter measures heat released by the recombination of hydrogen atoms into molecules on a thin wire. As a demonstration, the…
We present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage…
Extreme Ultraviolet (EUV) lithography is the state-of-the-art process in semiconductor fabrication, yet its spatial resolution is fundamentally limited by the ``blur'' originating from absorption of photons at 92 eV, which induce physical…