English
Related papers

Related papers: Absolute efficiency of a two-stage microchannel pl…

200 papers

Modern momentum imaging techniques allow for the investigation of complex molecules in the gas phase by detection of several fragment ions in coincidence. For these studies, it is of great importance that the single-particle detection…

In this paper, the detection efficiency of a large area neutron sensitive microchannel plate detector has been evaluated. A 6LiF/ZnS detector was employed as the benchmark detector, the TOF spectra of these two detectors were simultaneously…

Instrumentation and Detectors · Physics 2017-02-08 Yiming Wang , Yigang Yang , Ren Liu

Nowadays, Microchannel Plate (MCP), as a kind of electron multipliers based on the secondary electron emission, is widely used in many high-sensitive experiments, such as neutrino detection, which require the noise to be as low as possible,…

Instrumentation and Detectors · Physics 2024-05-30 Huaxing Peng , Baojun Yan , Han Miao , Shulin Liu , Binting Zhang

Composite detectors made of stainless steel converters and multigap resistive plate chambers have been irradiated with quasi-monoenergetic neutrons with a peak energy of 175MeV. The neutron detection efficiency has been determined using two…

Microchannel plates (MCPs) were recently proposed as novel type of cathodes for electron guns, suitable for applications in design of electron lenses. We report results of the first systematic study of microchannel plate based…

Accelerator Physics · Physics 2018-07-12 M. Haughey , V. Shiltsev , G. Stancari

Multi Micro-Channel-Plate Photomultiplier tubes (MCP-PMT) with High Collection Efficiency (Hi-CE) MCPs are developed and characterised. With these Hi-CE MCPs more than 90% of photoelectrons emitted from the photocathode can be detected;…

Instrumentation and Detectors · Physics 2018-03-14 D. A. Orlov , T. Ruardij , S. Duarte Pinto , R. Glazenborg , E. Kernen

Micro-channel plate (MCP) detectors, when used at pulsed-neutron-source instruments, offer the possibility of high spatial resolution and high contrast imaging with pixel-level spectroscopic information. Here we demonstrate the possibility…

A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude,…

Microchannel plate photodetectors provide both picosecond time resolution and sub-millimeter position resolution, making them attractive photosensors for particle identification detectors of a future U.S. Electron Ion Collider. We have…

Instrumentation and Detectors · Physics 2018-12-20 Junqi Xie , Mohammad Hattawy , Mickey Chiu , Kawtar Hafidi , Edward May , Jose Repond , Robert Wagner , Lei Xia

A two-dimensional position-sensitive microchannel plate detector, with a {\O}100 mm sensitive area and equipped with four integrated amplifiers, is realized with a new anode scheme. The anode is constructed by two independent…

Instrumentation and Detectors · Physics 2018-08-01 Yuezhao Zhang , Deyang Yu , Junliang Liu , Liping Yang , Wei Wang , Xiaoxiao Li , Xiaona Zhu , Xiaoxun Song , Xinfei Hui , Wei Xi , Xin Li , Huiping Liu , Xiaohong Cai

Hundreds of concurrent collisions per bunch crossing are expected at future hadron colliders. Precision timing calorimetry has been advocated as a way to mitigate the pileup effects and, thanks to their excellent time resolution,…

The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same…

A new type of resistive plate chamber with thin-film electrodes based on diamond-like carbon is under development for background identification in the MEG II experiment. Installed in a low-momentum and high-intensity muon beam, the detector…

Instrumentation and Detectors · Physics 2023-07-19 Kensuke Yamamoto , Sei Ban , Kei Ieki , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Atsushi Oya , Masato Takahashi

We present a comprehensive characterization of the LAPPD Gen-II, a large-area microchannel-plate photomultiplier tube (MCP-PMT) equipped with a capacitively coupled sensing (readout) electrode. Two detector variants with different…

Instrumentation and Detectors · Physics 2025-12-03 S. Korpar , R. Dolenec , F. Grijalva , A. Lozar , A. Kodrič , P. Križan , S. Parashari , R. Pestotnik , A. Seljak , D. Žontar

An advanced technique for a two-dimensional real time visualization of cluster beams in vacuum as well as of the overlap volume of cluster beams with particle accelerator beams is presented. The detection system consists of an array of…

The PANDA experiment at the FAIR facility at GSI will study hadron physics using a high intensity antiproton beam of up to 15 GeV/c momentum to perform high precision spectroscopy. Two DIRC detectors with their image planes residing in an…

We report on the response of microchannel plates (MCPs) to single relativistic particles and to electromagnetic showers. Particle detection by means of secondary emission of electrons at the MCP surface has long been proposed and is used…

We describe a high resolution imaging detector based on a single 80 mm micro-channel-plate (MCP) and a phosphor screen mounted on a UHV flange of only 100 mm inner diameter. It relies on standard components and we describe its performance…

Instrumentation and Detectors · Physics 2018-05-30 Sylvain Lupone , Pierre Soulisse , Philippe Roncin

We propose an alternative approach for the detection of fast neutrons in the energy range from 10-4 to 5 MeV based on 10B-RPCs (hybrid double-gap Resistive Plate Chambers with 10B4C neutron converters) surrounded by a polyethylene…

Instrumentation and Detectors · Physics 2022-02-23 A. Morozov , L. M. S. Margato , A. Blanco , D. Galaviz

We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$\mu$m and a resolution of…