English
Related papers

Related papers: Improving position resolution of neutron detectors…

200 papers

The principle of using strongly scattering materials to recover efficiency in neutron detectors, via back-scattering of unconverted thermal neutrons, is discussed in general. Feasibility of the method is illustrated through Geant4-based…

Instrumentation and Detectors · Physics 2015-09-11 Thomas Kittelmann , Esben Klinkby , Xiao Xiao Cai , Kalliopi Kanaki , Carsten P Cooper-Jensen , Richard Hall-Wilton

Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $\mu$m has been achieved, which is equivalent to an UCN energy resolution below…

A double-helix electrode configuration is combined with a $^{10}$B powder coating technique to build large-area (9 in $\times$ 36 in) neutron detectors. The neutron detection efficiency for each of the four prototypes is comparable to a…

Instrumentation and Detectors · Physics 2023-08-22 Zhehui Wang , C. L. Morris , J. D. Bacon , M. I. Brockwell , J. C. Ramsey

The Helium-3 shortage and the growing interest in neutron science constitute a driving factor in developing new neutron detection technologies. In this work, we report the development of a double-GEM detector prototype that uses a…

Amorphous boron carbide (B4C) thin films are by far the most popular form for the neutron converting layers in the 10B-based neutron detectors, which are a rising trend in detector technologies in response to the increasing scarcity and…

Due to the Helium-3 crisis, alternatives to the standard neutron detection techniques are becoming urgent. In addition, the instruments of the European Spallation Source (ESS) require advances in the state of the art of neutron detection.…

The worldwide need to replace 3He for the neutron detection has triggered R&D on new technologies and methods. A promising one is based on commercial solid state silicon detectors coupled with thin neutron converter layers containing 6Li.…

Instrumentation and Detectors · Physics 2016-01-20 A. Pappalardo , M. Barbagallo , L. Cosentino , C. Marchetta , A. Musumarra , C. Scirè , S. Scirè , G. Vecchio , P. Finocchiaro

An optimized design of a neutron detector based on timing RPCs (Resistive Plate Chambers) with boron-10 neutron converters is presented. The detector is composed of a stack of ten double gap RPCs with aluminium cathode plates coated on both…

Instrumentation and Detectors · Physics 2023-05-03 L. M. S. Margato , G. Canezin , A. Morozov , A. Blanco , J. Saraiva , L. Lopes , P. Fonte

In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and $\gamma$-ray Compton scatterer of the novel dual \g-ray and neutron imaging system GN-Vision, which aims at…

A novel large volume spherical proportional counter, recently developed, is used for neutron measurements. Gas mixtures of $N_{2}$ with $C_{2}H_{6}$ and pure $N_{2}$ are studied for thermal and fast neutron detection, providing a new way…

The 3He-based neutron detectors are no longer the default solution for neutron scattering applications. Both the inability of fulfilling the requirements in performance, needed for the new instruments, and the shortage of 3He, drove a…

Instrumentation and Detectors · Physics 2020-03-13 Giacomo Mauri , Francesco Messi , Kalliopi Kanaki , Richard Hall-Wilton , Francesco Piscitelli

Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare 3He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have…

Measuring slow neutrons is difficult when the radiation field also contains charged particles and fast neutrons, especially when the radiation composition is not known in advance. In this work, we present a tested method to measure slow…

Nuclear Experiment · Physics 2026-01-22 Ankit Kumar , Tushar Verma , Pankaj Jain , Raj Ganesh Pala , K. P. Rajeev

Neutron scattering techniques offer a unique combination of structural and the dynamic information of atomic and molecular systems over a wide range of distances and times. The increasing complexity in science investigations driven by…

Instrumentation and Detectors · Physics 2019-05-30 Giacomo Mauri

The neutron detection efficiency of Columbia Resin 39 (CR-39) nuclear track detectors was assessed for AmBe, 252Cf, and D-T (14 MeV) neutron source spectra. A boron nitride (BN) coating for CR-39 was developed to enhance the neutron…

Instrumentation and Detectors · Physics 2025-10-27 Noah DAmico , Sandeep Puri , Ian Jones , Andrew Gillespie , Cuikun Lin , Bo Zhao , R. V. Duncan

We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in…

A new method for directional fast neutron detection is proposed based on a neutron time projection chamber (TPC) and position-sensitive plastic scintillation detectors. The detection system can efficiently locate the approximate location of…

Instrumentation and Detectors · Physics 2019-07-11 Yidong Fu , Yang Tian , Yulan Li , Jian Yang , Jin Li

The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…

In this study, we have developed a new sub-MeV neutron detector that has a high position resolution, energy resolution, directional sensitivity, and low background. The detector is based on a super-fine-grained nuclear emulsion, called the…

Instrumentation and Detectors · Physics 2022-09-01 T. Shiraishi , I. Todoroki , T. Naka , A. Umemoto , R. Kobayashi , O. Sato

A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$\alpha$0$\gamma$)$^7$Li (6%) and $^{10}$B(n,$\alpha$1$\gamma$)$^7$Li (94%). The experiments, which extend…