English
Related papers

Related papers: A novel wide-angle Compton Scanner setup to study …

200 papers

A novel design for an inexpensive depth of interaction capable detector for gamma rays, suitable for nuclear medical applications, especially Positron Emission Tomography, has been developed. The design takes advantage of the strong…

Medical Physics · Physics 2009-09-29 Christoph W. Lerche

GRETA, the Gamma-Ray Energy Tracking Array, is an array of highly-segmented HPGe detectors designed to track {\gamma}-rays emitted in beam-physics experiments. Its high detection efficiency and state-of-the-art position resolution make it…

Instrumentation and Detectors · Physics 2021-07-05 Robert Crabbs , I-Yang Lee , Kai Vetter

Scintillator detector response modelling has become an essential tool in various research fields such as particle and nuclear physics, astronomy or geophysics. Yet, due to the system complexity and the requirement for accurate electron…

Instrumentation and Detectors · Physics 2023-12-05 David Breitenmoser , Francesco Cerutti , Gernot Butterweck , Malgorzata Magdalena Kasprzak , Sabine Mayer

Compton telescopes rely on the dominant interaction mechanism in the MeV gamma-ray energy range: Compton scattering. By precisely recording the position and energy of multiple Compton scatter interactions in a detector volume, a photon's…

Instrumentation and Methods for Astrophysics · Physics 2023-04-05 Carolyn Kierans , Tadayuki Takahashi , Gottfried Kanbach

We have developed a photon detection system for muonic X-ray spectroscopy. The detector system consists of high-purity germanium detectors with BGO Compton suppressors. The signals from the detectors are readout with a digital acquisition…

We show that a strong laser pulse combined with a strong x-ray pulse can be employed in a detection scheme for characterizing high-energy $\gamma$-ray pulses down to the zeptosecond timescale. The scheme employs streak imaging technique…

Instrumentation and Detectors · Physics 2015-05-28 K. Z. Hatsagortsyan , A. Ipp , J. Evers , A. Di Piazza , C. H. Keitel

For the first time, planar high-purity germanium detectors with thin amorphous germanium contacts were successfully operated directly in liquid nitrogen and liquid argon in a cryostat at the Max-Planck-Institut fuer Physics in Munich. The…

Instrumentation and Detectors · Physics 2020-08-04 R. Panth , J. Liu , I. Abt , X. Liu , O. Schulz , W. -Z. Wei , H. Mei , D. -M. Mei , G. -J. Wang

The Compton camera is a gamma-ray imaging device developed in the 1970s. In the 1990s, the COMPTEL detector onboard the CGRO was the first to utilize a Compton camera for MeV all-sky survey observations. Recently, various Compton cameras…

The GERmanium Detector Array, GERDA, is designed for the search for ``neutrinoless double beta decay'' (0-nu-2-beta) with germanium detectors enriched in Ge76. An 18-fold segmented prototype detector for GERDA Phase II was exposed to an…

Nuclear Experiment · Physics 2008-11-26 I. Abt , A. Caldwell , K. Kroeninger , J. Liu , X. Liu , B. Majorovits

Photon counting radiation detectors have become an integral part of medical imaging modalities such as Positron Emission Tomography or Computed Tomography. One of the most promising detectors is the wide bandgap room temperature…

Instrumentation and Detectors · Physics 2023-11-02 Sandeep K. Chaudhuri , Qinyang Li , Krishna C. Mandal , Jianjun Hu

Pulse-shape analysis of the ionization signals from germanium gamma-ray spectrometers is a method for obtaining information that can characterize an event beyond just the total energy deposited in the crystal. However, as typically…

Nuclear Experiment · Physics 2008-11-26 R. Suarez , J. L. Orrell , C. E. Aalseth , T. W. Hossbach , H. S. Miley

We report on the construction and upgrade of a Lawrence Berkeley National Laboratory Cosmic Muons Detector. We modify the electronics and mechanics to achieve a highly efficient gamma-ray and cosmic-ray detector. Each detector module uses a…

Instrumentation and Detectors · Physics 2011-07-25 Abdel G. Bachri , Perry C. Grant , Azriel Goldschmidt

Optical imaging of quantum emitters is essential for a wide range of quantum applications. Conventional confocal imaging relies on point-by-point raster scanning, which is inherently time-consuming and photon-inefficient, particularly for…

A Compton gamma imager has been developed for use in consequence management operations and in security investigations. The imager uses solid inorganic scintillator, known for robust performance in field survey conditions. The design was…

Recent progress on the development of very low noise high purity germanium ionization spectrometers has produced an instrument of 1.2 kg mass and excellent noise performance. The detector was installed in a low-background cryostat intended…

A high-brilliance ($\sim10^{24}$~photon.s$^{-1}$.mm$^{-2}$.mrd$^{-2}$/0.1\%) gamma-ray source experiment is currently being planned at Fermilab ($E_\gamma\simeq 1.1$~MeV)~[1]. The source implements a high-repetition-rate inverse Compton…

Accelerator Physics · Physics 2017-06-28 D. Mihalcea , A. Murokh , P. Piot , J. Ruan

We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up…

Instrumentation and Detectors · Physics 2015-06-12 D. S. Parno , M. Friend , V. Mamyan , F. Benmokhtar , A. Camsonne , G. B. Franklin , K. Paschke , B. Quinn

The hybrid pixel detector Timepix3 allows the measurement of the time and energy deposition of an event simultaneously in each 55 $\mu$m pixel, which makes Timepix3 a promising approach for a compact Compton camera. However, the angular…

Instrumentation and Detectors · Physics 2021-12-21 Jiaxing Wen , Xutao Zheng , Huaizhong Gao , Ming Zeng , Yuge Zhang , Minghai Yu , Yuchi Wu , Jirong Cang , Ge Ma , Zongqing Zhao

The physics studies at heavy-ion nucleus-nucleus collision experiments demand reliable detectors at high particle flux. Therefore, Gas Electron Multipliers (GEM) detectors, which show resilience to extreme radiation, are one of the prime…

High-purity germanium detectors are well suited to analysis the radioactivity of samples. In order to reduce the environmental background, low-activity lead and oxygen free copper are installed outside of the probe to shield gammas, outmost…