Applicator-specific phase space (PHSP) files recorded at the aperture exit reduce Monte Carlo dose calculation time by 30-50% for electron FLASH radiotherapy. However, positioning PHSP scoring planes coincident with the applicator-air…

Medical Physics · Physics 2026-05-05 Rafael Carballeira , Rongxiao Zhang , Kevin J. Willy , Hayley Cash , David J. Gladstone

The Fast Dose Calculator (FDC), a track repeating algorithm Monte Carlo method was initially developed for proton therapy. The validation for proton therapy has been demonstrated in a previous work. This method can be expanded to ion…

Medical Physics · Physics 2018-09-18 Qianxia Wang , Antony Adair , Yu Deng , Hongliang Chen , M Moyers , James Lin , Pablo Yepes

Ultra-high dose rate (FLASH) proton planning with only transmission beams (TBs) has limitations in normal tissue sparing. The single-energy spread-out Bragg peaks (SESOBPs) of FLASH dose rate have been demonstrated feasible for proton FLASH…

Background: Ultra-high-dose-rate (UHDR) radiation therapy has demonstrated promising potential in reducing toxicity to organs-at-risk (OARs). Proton therapy is uniquely positioned to deliver UHDR by leveraging the Bragg peak in conjunction…

Medical Physics · Physics 2025-04-30 Jiayue Han , Ya-Nan Zhu , Aoxiang Wang , Wangyao Li , Yuting Lin , Hao Gao

Purpose: A Monte Carlo (MC) beam model and its implementation in a clinical treatment planning system (TPS, Varian Eclipse) are presented for a modified ultra-high dose-rate electron FLASH radiotherapy (eFLASH-RT) LINAC. Methods: The gantry…

We used the GEANT4 Monte Carlo MC Toolkit to simulate carbon ion beams incident on water, tissue, and bone, taking into account nuclear fragmentation reactions. Upon increasing the energy of the primary beam, the position of the Bragg-Peak…

Medical Physics · Physics 2021-02-26 M. Kh. Hamad

Background: FLASH radiation therapy (FLASH-RT) uses ultra-high dose rates to induce the FLASH effect, enhancing normal tissue sparing. In proton Bragg peak FLASH-RT, this effect is confined to high-dose regions near the target at deep…

Medical Physics · Physics 2025-05-12 Weijie Zhang , Xue Hong , Ya-Nan Zhu , Yuting Lin , Gregory Gan , Ronald C Chen , Hao Gao

We characterized the dosimetric properties of a clinical linear accelerator configured to deliver ultra-high dose rate (UHDR) irradiation to mice and cell-culture FLASH radiobiology experiments. UHDR electron beams were controlled by a…

Conventional beam orientation optimization (BOO) algorithms for IMRT assume that the same set of beam angles is used for all treatment fractions. In this paper we present a BOO formulation based on group sparsity that simultaneously…

Medical Physics · Physics 2018-03-14 Daniel O'Connor , Dan Nguyen , Dan Ruan , Victoria Yu , Ke Sheng

Introduction: We developed and evaluated a method for dose calibration and monitoring under conventional and ultra-high dose rates for small animal experiments with small-field proton beams using a Faraday cup. Methods: We determined a…

Monte Carlo (MC) simulation of linacs depends on the accurate geometrical description of the head. The geometry of the Varian TrueBeam (TB) linac is not available to researchers. Instead, the company distributes phase-space files (PSFs) of…

The paper discusses some 3D simulations to compute the ionizing radiation dose during laser-plasma experiments leading to the generation of accelerated protons and electrons. Also, we suggest a new method to increase the measurement…

Instrumentation and Detectors · Physics 2019-10-02 M. Ganciu , A. Chirosca , A. Groza , E. Stancu , O. Stoican , D. B. Dreghici , B. Butoi , C. Ticos , B. Mihalcea , B. Cramariuc

In this study, two proton beam delivery designs, passive scattering proton therapy (PSPT) and pencil beam scanning (PBS), were quantitatively compared in terms of dosimetric indices. The GATE Monte Carlo code was used to simulate the proton…

Medical Physics · Physics 2022-09-21 A. Asadi , A. Akhavanallaf , S. A. Hosseini , H. Zaidi

Purpose: This study explored the feasibility of a streamlined pin-shaped ridge filter (pin-RF) design for single-energy proton FLASH planning. Methods: An inverse planning framework integrated within a TPS was established for FLASH…

We have developed a model for proton depth dose and lateral distributions based on Monte Carlo calculations (GEANT4) and an integration procedure of the Bethe-Bloch equation (BBE). The model accounts for the transport of primary and…

Medical Physics · Physics 2010-09-14 W. Ulmer , B. Schaffner

Background: With the advent of Intensity Modulated Radiotherapy (IMRT) and recently, Volumetric Modulated Arc Therapy (VMAT), treatment planning using Flattening Filter Free (FFF) beams can meet all of the energy requirements in radiation…

Medical Physics · Physics 2023-09-12 E. Ishmael Parsai , Elahheh Salari , Diana Shvydka , Jui Wan

The aim of the study was to investigate surface and buildup region doses for 6MV and 15MV photon beams using a Markus parallel-plate ionization chamber, GafChromic EBT3 film, and MOSFET detector for different field sizes and beam angles.…

Instrumentation and Detectors · Physics 2016-07-19 Ugur Akbas , Nazmiye Donmez Kesen , Canan Koksal , Hatice Bilge

Single minibeams of protons, $^{4}$He, $^{12}$C and $^{16}$O in water were modeled with Geant4, and their dose distributions were parameterized with double-Gauss-Rutherford (DGR) functions. Dose distributions from arrays of 16 parallel…

Medical Physics · Physics 2024-12-30 Savva Savenkov , Alexandr Svetlichnyi , Igor Pshenichnov

The proton irradiation accelerator is widely founded for industry application, and should be designed as compact, reliable, and easy operate. A 10 MeV proton beam is designed to be injected into the slow circulation ring with the repetition…

Accelerator Physics · Physics 2014-11-24 Yu-Wen An , Hong-Fei Ji , Sheng Wang , Shou-Yan Xu

Laser-accelerated protons have a great potential for innovative experiments in radiation biology due to the sub-picosecond pulse duration and high dose rate achievable. However, the broad angular divergence makes them not optimal for…

Medical Physics · Physics 2019-11-13 Marco Cavallone , Alessandro Flacco , Victor Malka