Related papers: Spectral-domain optical coherence tomography based…
Optical coherence tomography (OCT) has become a favorable device in the Dermatology discipline due to its moderate resolution and penetration depth. OCT images however contain a grainy pattern, called speckle, due to the use of a broadband…
Optical diffraction tomography is an indispensable tool for studying objects in three-dimensions due to its ability to accurately reconstruct scattering objects. Until now this technique has been limited to coherent light because spatial…
Intravascular polarimetry with catheter-based polarization-sensitive optical coherence tomography (PS-OCT) complements the high-resolution structural tomograms of OCT with morphological contrast available through polarimetry. Its clinical…
Optical coherence tomography (OCT) is a prevalent, interferometric, high-resolution imaging method with broad biomedical applications. Nonetheless, OCT images suffer from an artifact, called speckle which degrades the image quality. Digital…
Phase sensitive detection in spectral domain optical coherence tomography (SD-OCT) is a powerful method for functional imaging of biological events with high spatiotemporal resolution. The depth-dependent signal-to-noise ratio (SNR) is a…
Optical coherence tomography (OCT) as retina imaging technology is currently used by ophthalmologist as a non-invasive and non-contact method for diagnosis of agerelated degeneration (AMD) and diabetic macular edema (DME) diseases. Fluid…
Optical Coherence Tomography (OCT) is an imaging modality that has been widely adopted for visualizing corneal, retinal and limbal tissue structure with micron resolution. It can be used to diagnose pathological conditions of the eye, and…
Egyptian faience is a non-clay ceramic semi-transparent material, formed of a quartz core and alkali lime glaze with some cases exhibiting an interaction layer between them. Several possible glazing methods have been identified. Previous…
Speckle noise has long been an extensively studied problem in medical imaging. In recent years, there have been significant advances in leveraging deep learning methods for noise reduction. Nevertheless, adaptation of supervised learning…
We present the first demonstration of shot-noise limited supercontinuum-based spectral domain optical coherence tomography (SD-OCT) with axial resolution of 5.9 $\mu$m at a center wavelength of 1370 nm. Current supercontinuum-based SD-OCT…
Optical diffraction tomography (ODT) is an emerging 3D imaging technique that is used for the 3D reconstruction of the refractive index (RI) for semi-transparent samples. Various inverse models have been proposed to reconstruct the 3D RI…
Advances in optical coherence tomography (OCT) have enabled noninvasive imaging of substructures of the human retina with high spatial resolution. OCT examinations are now a standard procedure in clinics and an integral part of ophthalmic…
Despite significant advances in artificial intelligence (AI) for computer vision, its application in medical imaging has been limited by the burden and limits of expert-generated labels. We used images from optical coherence tomography…
We demonstrate experimentally ghost optical coherence tomography using a broadband incoherent supercontinuum light source with shot-to-shot random spectral fluctuations. The technique is based on ghost imaging in the spectral domain where…
Optical coherence Doppler tomography (ODT) is an emerging blood flow imaging technique. The fundamental unit of ODT is the 1D depth-resolved trace named raw A-scans (or A-line). A 2D ODT image (B-scan) is formed by reconstructing a…
A resolution enhancement technique for optical coherence tomography (OCT), based on Generative Adversarial Networks (GANs), was developed and investigated. GANs have been previously used for resolution enhancement of photography and optical…
Dispersion is a common phenomenon in optics due to the frequency dependence of the refractive index in polychromatic light. This issue, if left untreated in optical coherence tomography (OCT) imaging, leads to signal broadening of the…
Quantum Optical Coherence Tomography (Q-OCT) is a non-classical equivalent of Optical Coherence Tomography and is able to provide a twofold axial resolution increase and immunity to resolution-degrading dispersion. The main drawback of…
While optical coherence tomography (OCT) provides a resolution down to 1 micrometer it has difficulties to visualize cellular structures due to a lack of scattering contrast. By evaluating signal fluctuations, a significant contrast…
Optical coherence tomography (OCT) is a non-invasive imaging technique that can produce images of the eye at the microscopic level. OCT image segmentation to localise retinal layer boundaries is a fundamental procedure for diagnosing and…