English
Related papers

Related papers: Ultra-clean radon-free four cylinder magnetically-…

200 papers

Experiments based on noble elements such as gaseous or liquid argon or xenon utilize the ionization and scintillation properties of the target materials to detect radiation-induced recoils. A requirement for high light and charge yields is…

A high-flow radon removal system based on cryogenic distillation was developed and constructed to reduce radon-induced backgrounds in liquid xenon detectors for rare event searches such as XENONnT. A continuous purification of the XENONnT…

Instrumentation and Detectors · Physics 2022-12-28 M. Murra , D. Schulte , C. Huhmann , C. Weinheimer

This manuscript details the proof-of-concept of a small-scale cryogenic heat pump demonstrator, a technology designed to enable high-flow xenon distillation systems for the removal of $^{222}$Rn in future liquid xenon observatories such as…

Instrumentation and Detectors · Physics 2026-04-23 P. Schulte , D. Wenz , L. Althueser , R. Braun , V. Hannen , C. Huhmann , D. Koke , Y. -T. Lin , P. Unkhoff , C. Weinheimer

In order to recuperate the ultra-high purity xenon from PandaX-4T dark matter detector to high-pressure gas cylinders in emergency or at the end-of-run situation, a high speed ultra-high purity xenon recuperation system is designed and…

Instrumentation and Detectors · Physics 2022-09-16 Zhou Wang , Wenbo Ma , Tao Zhang , Li Zhao , Shuaijie Li , Xiangyi Cui , Jianglai Liu , Changbo Fu , Yonglin Ju , Qing Lin , Xiaohua Chen , Xun Chen , Xiuli Wang

A new method for measuring trace amounts of krypton in xenon using a cold trap with a residual gas analyzer has been developed, which achieves an increased sensitivity by temporarily reducing the pumping speed while expending a minimal…

Instrumentation and Detectors · Physics 2015-06-12 Ethan Brown , Stephan Rosendahl , Christian Huhmann , Christian Weinheimer , Hans Kettling

Pistons are elementary components of a wide variety of thermal engines, allowing to convert input fuel into rotational motion. Here, we propose a single-piston engine where the rotational degree of freedom is effectively realized by the…

Quantum Physics · Physics 2018-06-01 Alexandre Roulet , Stefan Nimmrichter , Jacob M. Taylor

We report on the development and performance of a high-sensitivity purity-analysis technique for gaseous xenon. The gas is sampled at macroscopic pressure from the system of interest using a UHV leak valve. The xenon present in the sample…

Instrumentation and Detectors · Physics 2011-05-09 D. S. Leonard , A. Dobi , C. Hall , L. Kaufman , T. Langford , S. Slutsky , Y. R. Yen

An online cryogenic distillation system for the removal of krypton and radon from xenon was designed and constructed for PandaX-4T, a highly sensitive dark matter detection experiment. The krypton content in a commercial xenon product is…

Instrumentation and Detectors · Physics 2021-08-11 Xiangyi Cui , Zhou Wang , Yonglin Ju , Xiuli Wang , Huaxuan Liu , Wenbo Ma , Jianglai Liu , Li Zhao , Xiangdong Ji , Shuaijie Li , Rui Yan , Haidong Sha , Peiyao Huang

The PandaX-30T is a proposed next-generation experiment to study dark matter and neutrinos using a dual-phase time projection chamber with \textasciitilde30 tons of liquid xenon. An innovative xenon handling subsystem of the PandaX-30T, the…

Instrumentation and Detectors · Physics 2023-06-07 Xiuli Wang , Zhuoqun Lei , Yonglin Ju , Jianglai Liu , Ning Zhou , Yu Chen , Zhou Wang , Xiangyi Cui , Yue Meng , Li Zhao

As part of the R2D2 (Rare Decays with Radial Detector) R&D, the use of a gas detector with a spherical or cylindrical cathode, equipped with a single anode and operating at high pressure, was studied for the search of rare phenomena such as…

PandaX-4T, the new generation of the PandaX detector, is a xenon dual-phase detector with about six tons of liquid xenon as target for dark matter search. A cryogenics and xenon handling system is designed to liquify and purify this large…

Instrumentation and Detectors · Physics 2021-08-11 Li Zhao , Xiangyi Cui , Wenbo Ma , Yingjie Fan , Karl Giboni , Tao Zhang , Jianglai Liu , Xiangdong Ji

The PandaX-xT is a next-generation experiment with broad scientific goals, including the search for dark matter, Neutrinoless Double Beta Decay, and astrophysical neutrinos, using a dual-phase time projection chamber with about 43 tons of…

Instrumentation and Detectors · Physics 2026-04-09 Xu Wang , Li Zhao , Xiang Xiao , Xiangyi Cui , Shuaijie Li , Jianglai Liu

We have developed an efficient cryogenic system with heat exchange and associated gas purification system, as a prototype for the XENON1T experiment. The XENON1T detector will use about 3 ton of liquid xenon (LXe) at a temperature of 175K…

Instrumentation and Detectors · Physics 2015-06-11 Elena Aprile , Ran Budnik , Bin Choi , Hugo Contreras , Karl Giboni , Luke Goetzke , Rafael Lang , Kyungeun Lim , Antonio melgarejo , Petr Shagin

Efficiency at maximum power (MP) output for an engine with a passive piston without mechanical controls between two reservoirs is theoretically studied. We enclose a hard core gas partitioned by a massive piston in a temperature-controlled…

Statistical Mechanics · Physics 2016-10-04 Tomohiko G. Sano , Hisao Hayakawa

Metastable states of noble gas atoms are typically produced by electrical discharge techniques or "all-optical" excitation methods. Here we combine electrical discharges with optical pumping to demonstrate "optically enhanced" production of…

Atomic Physics · Physics 2017-10-10 G. T. Hickman , J. D. Franson , T. B. Pittman

The operational characteristics of a Micromegas operating in pure xenon at the pressure range of 1 to 10 bar are investigated. The maximum charge gain achieved in each pressure is approximately constant, around 4x10^2, for xenon pressures…

Instrumentation and Detectors · Physics 2011-02-11 C. Balan , E. D. C. Freitas , T. Papaevangelou , I. Giomataris , H. Natal da Luz , C. M. B. Monteiro , J. M. F. dos Santos

An efficient cryogenic distillation system was designed and constructed for PandaX-4T dark matter detector based on the McCabe-Thiele (M-T) method and the conservation of mass and energy. This distillation system is designed to reduce the…

Liquid-xenon based particle detectors have been dramatically growing in size during the last years, and are now exceeding the one-ton scale. The required high xenon purity is usually achieved by continuous recirculation of xenon gas through…

Instrumentation and Detectors · Physics 2011-03-08 K. L. Giboni , E. Aprile , B. Choi , T. Haruyama , R. F. Lang , K. E. Lim , A. J. Melgarejo , G. Plante

The XENON1T experiment aims for the direct detection of dark matter in a cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be…

Instrumentation and Detectors · Physics 2017-05-09 XENON Collaboration , E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , F. Arneodo , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , E. Duchovni , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , D. Franco , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , R. Itay , B. Kaminsky , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , M. Le Calloch , Q. Lin , S. Lindemann , M. Lindner , J. A. M. Lopes A. Manfredini , I. Maris , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , Y. Meng , M. Messina , K. Micheneau , B. Miguez , A. Molinario , M. Murra , J. Naganoma , K. Ni , U. Oberlack , S. E. A. Orrigo , P. Pakarha , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , M. -C. Piro , V. Pizzella , G. Plante , N. Priel , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , S. Rosendahl , N. Rupp , R. Saldanha , J. M. F. dos Santos , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , A. Stein , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , N. Upole , H. Wang , Y. Wei , C. Weinheimer , J. Wulf , J. Ye , Y. Zhang , I. Cristescu
‹ Prev 1 2 3 10 Next ›