Related papers: Avalanche gain and its effect on energy resolution…
An approximate formula has been derived for gain fluctuations in cascaded gaseous detectors such as GEM-s, based on the assumption that the charge collection, avalanche formation and extraction steps are independent cascaded processes. In…
We further study the performance of single, double and triple Gas Electron Multiplier (GEM) detectors in pure noble gases at high pressures, in the range of 1-10 atm. We confirm that light noble gases, in particular He and its mixtures with…
The dependence of the avalanche charge gain in Thick Gas Electron Multipliers (THGEM) on the purity of Ne, Ar and Xe filling gases was investigated. The gain, measured with alpha-particles in standard conditions (atmospheric pressure, room…
In this paper, measurement results and experimental methodology are presented on the determination of multiplication distributions of avalanches initiated by single electron in GEM foils. The measurement relies on the amplification of…
The operation of a Micropattern Gaseous Detector (MPGD) comprising a cascade of two non-standard Gas Electron Multipliers (GEM) made from a 100 micrometer kapton foil was evaluated in pure krypton and in krypton-CO2 mixtures. The final…
Study of the stability of gain and energy resolution for a triple GEM detector has been performed under continuous radiation of X-ray with high rate, using premixed gas of Argon and CO$_2$ in 70/30 ratio and conventional NIM electronics. A…
We study the performance of two-phase avalanche detectors based on Gas Electron Multipliers (GEMs) and operated in an electron-avalanching mode in Ar and Xe. Emission, gain, energy resolution and stability characteristics of the detectors…
The Negative Ion Drift (NID) gas SF$_6$ has favourable properties for track reconstruction in directional Dark Matter (DM) searches utilising low pressure gaseous Time Projection Chambers (TPCs). However, the electronegative nature of the…
A quadruple GEM detector has been assembled in a standalone configuration and operated using Ar and CO$_2$ gas mixtures in proportions of 70:30 and 90:10. Detailed performance study of the detector has been made by using $^{106}$Ru-Rh…
We have developed a novel technique for the measurement of the size of avalanche fluctuations of gaseous detectors using a gating device (gating foil) prepared for the time projection chamber in the international linear collider experiment…
The CYGNO collaboration is developing next generation directional Dark Matter (DM) detection experiments, using gaseous Time Projection Chambers (TPCs), as a robust method for identifying Weakly Interacting Massive Particles (WIMPs) below…
Large area Gas Electron Multiplier (GEM) detectors have been the preferred choice for tracking devices in major nuclear and particle physics experiments. Uniformity over surface of the detector in terms of gain, energy resolution and…
Low-Gain Avalanche Detectors are gathering interest in the High-Energy Physics community thanks to their fast-timing and radiation-hardness properties, which are planned to be exploited, for example, in timing detectors for the upgrades of…
The ALICE experiment at LHC has planned to upgrade the TPC by replacing the MWPC with GEM based detecting elements to restrict the IBF to a tolerable value. However the variation of the gain as a function of physical parameters of…
The use of gaseous Time Projection Chambers enables the detection and the detailed study of rare events due to particles interactions with the atoms of the gas with energy releases as low as a few keV. Due to this capability, these…
The characteristic properties of two-phase Ar avalanche detectors, including those obtained with CsI photocathode, are further studied. Such detectors are relevant in the field of coherent neutrino-nucleus scattering and dark matter search…
Low pressure gaseous Negative Ion Time Projection Chambers (NITPCs) have been used previously by the DRIFT experiment to search for a directional Dark Matter (DM) signature. The main challenge with using a Negative Ion Drift (NID) gas…
The world's leading directional dark matter experiments currently all utilize low-pressure gas Time Projection Chamber (TPC) technologies. We discuss some of the challenges for this technology, for which balancing the goal of achieving the…
Study of the uniformity of gain, energy resolution and count rate over active area of a triple GEM detector has been performed using a strong Fe55 X-ray source with premixed gas of Argon and CO2 in 70/30 ratio and conventional NIM…
A systematic study is performed to measure the ion backflow fraction of the GEM detectors. The effects of different voltage configurations and Ar/CO_2 gas mixtures, in ratios of 70:30, 80:20 and 90:10, on positive ion fraction are…