Related papers: Test beam characterization of sensor prototypes fo…
A tightly focused pulsed laser can locally modify the crystal structure inside the bulk of a scintillator. The result is incorporation of so-called optical barriers with a refractive index (RI) different from that of the crystal bulk, that…
We report on a beam test of a Silicon Photo-Multiplier (SiPM)-on-tile Zero Degree Calorimeter (ZDC) prototype developed for the future Electron-Ion Collider (EIC). The detector implements the staggered scintillator-tile geometry envisioned…
LaBr3:Ce crystals, with photomultiplier or single SiPM readout (up to 3x3 mm$^2$) have been introduced for radiation imaging in medical physics. An R&D was pursued with 1/2" and 1" LaBr3:Ce crystals, from different producers, to realize…
The TORCH time-of-flight detector is designed to provide a 15 ps timing resolution for charged particles, resulting in $\pi$/$K$ particle identification up to 10 GeV/c momentum over a 10 m flight path. Cherenkov photons, produced in a…
We propose a large-area, cost-effective Muon Telescope Detector (MTD) for the Solenoidal Tracker at RHIC (STAR) at mid-rapidity and for the next generation of detectors at a possible electron-ion collider. We utilize Multi-gap Resistive…
A second monolithic silicon pixel prototype was produced for the MONOLITH project. The ASIC contains a matrix of hexagonal pixels with 100 {\mu}m pitch, readout by a low-noise and very fast SiGe HBT frontend electronics. Wafers with 50…
The Mu2e experiment at Fermilab aims to measure the charged lepton flavor violating neutrinoless muon to electron conversion. The goal of the experiment is to reach a single event sensitivity of 2.5 x 10^{-17}, to set an upper limit on the…
To achieve high precision and accuracy for mass measurements of exotic nuclei by Time-of-flight (TOF) methods: high-resolution beam-line magnetic-rigidity time-of-flight (B$\rho$-TOF) and in-ring isochronous mass spectrometry (IMS), a…
The existing ATLAS Tracker will be at its functional limit for particle fluences of 10^15 neq/cm^2 (LHC). Thus for the upgrades at smaller radii like in the case of the planned Insertable B-Layer (IBL) and for increased LHC luminosities…
TRopIcal DEep-sea Neutrino Telescope (TRIDENT) plans to incorporate silicon photomultipliers (SiPMs) with superior time resolution in addition to photomultiplier tubes (PMTs) into its detection units, namely hybrid Digital Optical Modules…
The analog hadron calorimeter for the International Linear Collider (ILC) of the CALICE collaboration utilized novel silicon detectors, the Sillicon Photomultipliers (SiPMs), for the detection of scintillation light coming from very small…
The design and tests of Timing Counter elements for the upgrade of the MEG experiment, MEG II,is presented. The detector is based on several small plates of scintillator with a Silicon PhotoMultipliers dual-side readout. The optimisation of…
A systematic study is conducted to understand the coincident resolving time (CRT) for a pair of Lutetium-yttrium oxyorthosilicate (LYSO) and the plastic scintillation detector bars under the Geant4 framework. Crystals are coupled to a…
The phase 1 upgrade of the CMS pixel detector has been designed to maintain the tracking performance at instantaneous luminosities of $2 \times 10^{34} \mathrm{~cm}^{-2} \mathrm{~s}^{-1}$. Both barrel and endcap disk systems now feature one…
The T2K neutrino experiment at J-PARC uses a set of near detectors to measure the properties of an unoscillated neutrino beam and neutrino interaction cross-sections. One of the sub-detectors of the near-detector complex, the side muon…
The Accelerator Mass Spectrometry technique makes it possible to measure rare long-lived isotopes such as $^{10}$Be, $^{14}$C, $^{26}$Al, $^{36}$Cl, $^{41}$Ca and $^{129}$I. The content of these isotopes can be at the level of 10$^{-15}$ of…
We report on several versions of the calibration and monitoring system dedicated to scintillator tile calorimeters built within the CALICE collaboration and intended for future linear collider experiments. Whereas the first, a 1 m3 analogue…
A Lead-Scintillating Fiber (Pb/SciFi) prototype for the Barrel Imaging Calorimeter (BIC) at the Electron--Ion Collider (EIC) was tested with electron beams at the CERN PS T10 beam line in August 2024. The prototype consisted of unit modules…
The high energy physics community has recently identified an $e^+e^-$ Higgs factory as one of the next-generation collider experiments, following the completion of the High Luminosity LHC program at CERN.The moderate radiation levels…
Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In…