English
Related papers

Related papers: Treatment Planning System for Electron FLASH Radio…

200 papers

FLASH radiotherapy (FLASH-RT) achieves tumor control comparable to conventional dose-rate irradiation (CONV-RT) while significantly reducing radiation damage to normal tissues. However, the physical conditions triggering the FLASH sparing…

Purpose: To develop a single-shot multi-slice T1 mapping method by combing simultaneous multi-slice (SMS) excitations, single-shot inversion-recovery (IR) radial fast low-angle shot (FLASH) and a nonlinear model-based reconstruction method.…

To develop an automated workflow for rectal cancer three-dimensional conformal radiotherapy treatment planning that combines deep-learning(DL) aperture predictions and forward-planning algorithms. We designed an algorithm to automate the…

This paper describes the development and validation of a Monte Carlo (MC) dose computing module dedicated to organ dose calculations of patients undergoing nuclear medicine (NM) internal radiation exposures involving 18F-FDG PET/CT…

Medical Physics · Physics 2022-03-30 Zhao Peng , Yu Lu , Yao Xu , Yongzhe Li , Bo Cheng , Ming Ni , Zhi Chen , Xi Pei , Qiang Xie , Shicun Wang , X. George Xu

Next-generation gamma beams beams from laser Compton-backscattering facilities like ELI-NP (Bucharest)] or MEGa-Ray (Livermore) will drastically exceed the photon flux presently available at existing facilities, reaching or even exceeding…

Instrumentation and Detectors · Physics 2015-06-03 P. G. Thirolf , D. Habs , D. Filipescu , R. Gernhäuser , M. M. Günther , M. Jentschel , N. Marginean , N. Pietralla

Purpose: To describe a concept of a compact electron accelerator for external radiation therapy with variable energy in the range of 6 - 20 MeV, based on linotron principle. Methods: Beam dynamics simulation using the CST and MAD-X code.…

Accelerator Physics · Physics 2020-08-04 L. Yu. Ovchinnikova , V. I. Shvedunov

Purpose: To develop a model-based nonlinear reconstruction for simultaneous water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or fat fraction (FF) mapping using single-shot inversion-recovery (IR) multi-echo radial FLASH. Methods: The…

Proton beam therapy has been developed to irradiate the tumor with higher precision and dose conformity compared to conventional X-ray irradiation. The dose conformity of this treatment modality may be further improved if narrower proton…

Background and purpose: IMPT faces challenges in lung cancer treatment, like maintaining plan robustness for moving tumors against setup, range errors, and interplay effects. Proton Arc Therapy (PAT) is an alternative to maintain target…

Improving effective treatment plans in carbon ion therapy, especially for targeting radioresistant tumors located in deep seated regions while sparing normal tissues, depends on a precise and computationally efficient dose calculation…

Medical Physics · Physics 2025-06-25 Fulya Halıcılar , Metin Arık

The next great leap toward improving treatment of cancer with radiation will require the combined use of online adaptive and magnetic resonance guided radiation therapy techniques with automatic X-ray beam orientation selection.…

Medical Physics · Physics 2019-08-14 Ryan Neph , Yangsibo Huang , Youming Yang , Ke Sheng

The purpose of this study is to evaluate the clinical usefulness of modulated arc (mARC) treatment techniques. The mARC treatment plans of the non-small cell lung cancer (NSCLC) patients were performed in order to verify the clinical…

The interplay between the beam delivery time structure and the patient motion makes 4D dose calculation (4DDC) important when treating moving tumors with intensity modulated proton therapy. 4DDC based on phase sorting of a 4DCT suffers from…

Medical Physics · Physics 2023-10-13 Ivar Bengtsson , Erik Engwall , Albin Fredriksson , Lars Glimelius

Background: Promising results for mammary carcinoma treatment with photodynamic therapy (PDT) presuppose a careful selection of irradiation light wavelength. Methods: 4T1 tumors implanted in NOD-SCID mice were treated with Metvix-PDT under…

This research considers potential dose increase in target due to cisplatin (Pt) concentration and radiation type. Cisplatin concentrations from 0.003 to 120 mM were used. Monte-Carlo simulation of Linear accelerator (Elekta Synergy) and…

Medical Physics · Physics 2020-08-26 A. A. Baulin

We propose a fast beam orientation selection method, based on deep neural networks (DNN), capable of developing a plan comparable to those by the state-of-the-art column generation method. The novelty of Our model lies in its supervised…

Medical Physics · Physics 2019-12-23 Azar Sadeghnejad Barkousaraie , Olalekan Ogunmolu , Steve Jiang , Dan Nguyen

Quasi-monochromatic, high energy and highly polarized $\gamma$-ray beam sources based on Compton scattering of laser photons (LCS) on relativistic electrons have developed for the last few decades as established instruments for nuclear…

Instrumentation and Detectors · Physics 2022-11-11 Dan Filipescu

Purpose. - Radiotherapy is an important treatment for prostate cancer.During treatment sessions, bladder and rectal repletion is difficult to quantify and cannot be measured with a single and initial CT scan acquisition. Some methods, such…

Medical Physics · Physics 2011-04-06 Cyril Voyant , Katia Biffi , Leschi Delphine , Jerome Briancon , Celine Lantieri Marcovici

FLASH radiation therapy calls for the delivery of fast bursted spills of particles with dose delivery times of the order of milliseconds. The requirements overlap with fundamental physics experimental requests that are being studied at…

Accelerator Physics · Physics 2022-08-31 Pablo A. Arrutia Sota , Philip N. Burrows , Matthew A. Fraser , Francesco M. Velotti

Radiotherapy using very high-energy electron (VHEE) beams generated by a laser-plasma accelerator has garnered significant interest due to its dose distribution capabilities and potential to address limitations of traditional photon-based…

‹ Prev 1 4 5 6 7 8 10 Next ›