English
Related papers

Related papers: AC/DC characterization of a Ti/Au TES with Au/Bi a…

200 papers

The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution measurement of particles such as X-rays. X-rays with energies…

Transition-edge sensors (TESs) are sensitive devices for detecting photons from millimeter radiation to gamma rays. Their photon counting efficiency and collecting area benefit from large-array multiplexing scheme, and therefore the…

Instrumentation and Methods for Astrophysics · Physics 2024-04-03 N. Li , G. Liao , D. Yan , Y. Xu , Y. Zhang , Z. Liu , S. Yuan , Y. Zhang , H. Gao , Y. Li , Y. Gu , C. Liu , H. Li , Z. Li , X. Ren

The Advanced Telescope for High-Energy Astrophysics (Athena) has been selected by ESA as its second large-class mission. The future European X-ray observatory will study the hot and energetic Universe with its launch foreseen in 2028.…

We present a comprehensive analysis of high-resolution transition-edge sensors (TESs) as a quantum sensing platform for detecting dark matter (DM). Operating near the thermodynamic noise limit with sub-eV energy resolution, TESs offer a…

High Energy Physics - Phenomenology · Physics 2025-06-13 Muping Chen , Volodymyr Takhistov , Kazunori Nakayama , Kaori Hattori

Transition-edge sensors (TESs) as microcalorimeters offer high resolving power, owning to their sharp response and low operating temperature. In the hard X-ray regime and above, the demand for high quantum-efficiency requires the use of…

Transition edge sensors (TESs) are superconducting energy-resolving microcalorimeters that have demonstrated low background rates as well as quantum efficiencies close to unity for photons at optical and near-infrared wavelengths. This…

We report initial measurements on our firstMoAu Transition Edge Sensors (TESs). The TESs formed from a bilayer of 40 nm of Mo and 106 nm of Au showed transition temperatures of about 320 mK, higher than identical TESs with a MoCu bilayer…

Instrumentation and Detectors · Physics 2014-01-13 D. J. Goldie , A. V. Velichko , D. M. Glowacka , S. Withington

Electroplated Bismuth (Bi) is commonly used in Transition-Edge Sensors (TESs) for X-rays because of its high stopping power and low heat capacity. Electroplated Bi is usually grown on top of another metal that acts as seed layer, typically…

Instrumentation and Detectors · Physics 2024-12-11 Orlando Quaranta , Lisa M. Gades , Cindy Xue , Ralu Divan , Umeshkumar M. Patel , Tejas Guruswamy , Antonino Miceli

The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES…

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at $\sim$10 mK, are usually…

We are developing a kilo-pixels Ti/Au TES array as a backup option for Athena X-IFU. Here we report on single-pixel performance of a 32$\times$32 array operated in a Frequency Division Multiplexing (FDM) readout system, with bias…

Experimental searches for axions or dark photons that couple to the standard model photon require photosensors with low noise, broadband sensitivity, and near zero backgrounds. Here, we introduce an experimental architecture, in which a…

Instrumentation and Detectors · Physics 2025-05-30 Roger K. Romani , Yen-Yung Chang , Rupak Mahapatra , Mark Platt , Maggie Reed , Ivar Rydstrom , Bernard Sadoulet , Bruno Serfass , Matt Pyle

The so-called excess noise limits the energy resolution of transition-edge sensor (TES) detectors, and its physical origin has been unclear, with many competing models proposed. Here we present the noise and impedance data analysis of a…

Superconducting Transition-Edge Sensor (TES) bolometers are used for cosmic microwave background (CMB) observations. We used a testbed to evaluate the thermal performance of TES bolometers in regard to the saturation power Psat and…

Instrumentation and Methods for Astrophysics · Physics 2022-09-28 Yume Nishinomiya , Akito Kusaka , Kenji Kiuchi , Tomoki Terasaki , Johannes Hubmayr , Adrian Lee , Heather McCarrick , Aritoki Suzuki , Benjamin Westbrook

We present the electro-thermal characterization of transition-edge sensor (TES) detectors suspended on Si membranes fabricated using a silicon-on-insulator (SOI) wafer. The use of an all-silicon fabrication platform, in contrast to the more…

Superconducting transition-edge sensors (TES) are extremely sensitive microcalorimeters used as photon detectors with unparalleled energy resolution. They have found application from measuring astronomical spectra through to determining the…

Athena is a space-based X-ray observatory intended for exploration of the hot and energetic universe. One of the science instruments on Athena will be the X-ray Integrated Field Unit (X-IFU), which is a cryogenic X-ray spectrometer, based…

Instrumentation and Methods for Astrophysics · Physics 2016-11-17 J. van der Kuur , L. G. Gottardi , H. Akamatsu , B. J. van Leeuwen , R. den Hartog , D. Haas , M. Kiviranta , B. J. Jackson

We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a prototype 24-pixel hard X-ray array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated…

Instrumentation and Detectors · Physics 2025-02-19 Panthita Triamkitsawat , Tejas Guruswamy , Orlando Quaranta , Lisa Gades , Umeshkumar Patel , Antonino Miceli

The Simons Observatory aims to field 70,000 Transition-Edge Sensor (TES) bolometers to measure the Cosmic Microwave Background. With so many detectors, rapid but accurate validation of their properties prior to their integration into…

Instrumentation and Detectors · Physics 2023-06-21 Rita F. Sonka , Shannon M. Duff , Daniel Dutcher , Suzanne T. Staggs

The baseline energy-resolution performance for the current generation of large-mass, low-temperature calorimeters (utilizing TES and NTD sensor technologies) is $>2$ orders of magnitude worse than theoretical predictions. A detailed study…

Instrumentation and Methods for Astrophysics · Physics 2015-03-13 Matt Pyle , Enectali Figueroa-Feliciano , Bernard Sadoulet