Related papers: AC/DC characterization of a Ti/Au TES with Au/Bi a…
Cryogenic characterization of transition-edge sensor (TES) bolometers is a time- and labor-intensive process. As new experiments deploy larger and larger arrays of TES bolometers, the testing process will become more of a bottleneck. Thus…
We propose to operate a superconducting transition edge sensor (TES) using a different type of biasing, in which the resistance of the TES is kept constant by means of feedback on the bias voltage and is independent of the incoming signal…
We are developing the Cryogenic AntiCoincidence detector (CryoAC) of the ATHENA X-IFU spectrometer. It is a TES-based particle detector aimed to reduce the background of the instrument. Here, we present the result obtained with the last…
Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now…
Superconducting transition-edge sensors (TESs) carried by X-ray telescopes are powerful tools for the study of neutron stars and black holes. Several methods, such as optimal filtering or principal component analysis, have already been…
We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal,…
The ATHENA X-ray Observatory is the second large-class mission in the ESA Cosmic Vision 2015-2025 science programme. One of the two on-board instruments is the X-IFU, an imaging spectrometer based on a large array of TES microcalorimeters.…
To improve both scalability and noise-filtering capability of a Transition-Edge Sensor (TES), a new concept of a thin-film detector is suggested, which is based on embedding a microbridge TES into a high-Q planar GHz range resonator weakly…
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to…
Transition-edge sensors (TES) are photon-number resolving calorimetric spectrometers with near unit efficiency. Their recovery time, which is on the order of microseconds, limits the number resolving ability and timing accuracy in high…
The digital frequency domain multiplexing (DfMux) technique is widely used for astrophysical instruments with large detector arrays. Detailed detector characterization is required for instrument calibration and systematics control. We…
AlMn alloy flms are widely fabricated into superconducting transition edge sensors (TESs) for the detection of cosmic microwave background radiation. However, the application in X-ray or gamma-ray detection based on AlMn TES is rarely…
Transition-edge sensors (TESs) can be used in high-resolution photon detection, exploiting the steep slope of the resistance in the superconducting-to-normal transition edge. Normal metal bars on the TES film are commonly used to engineer…
We describe a process route to fabricate arrays of Ultra-low-Noise MoAu Transition Edge Sensors (TESs). The low thermal conductance required for space applications is achieved using 200 nm-thick Silicon Nitride (SiNx ) patterned to form…
We describe the design and measurement of feedhorn-coupled, transition-edge sensor (TES) polarimeters with two passbands centered at 220 GHz and 280 GHz, intended for observations of the cosmic microwave background. Each pixel couples…
Transition-Edge Sensors (TESs) are two-dimensional superconducting films used to detect energy or power. TESs are voltage biased in the resistive transition where the film resistance is both finite and a strong function of temperature.…
Frequency domain multiplexing (fMux) is an established technique for the readout of transition-edge sensor (TES) bolometers in millimeter-wavelength astrophysical instrumentation. In fMux, the signals from multiple detectors are read out on…
We report on efforts to improve the speed of low-G far-infrared transition-edged-sensed bolometers. We use a fabrication process that does not require any dry etch steps to reduce heat capacity on the suspended device and measure a…
We have succeeded in operating a transition-edge sensor (TES) spectrometer and evaluating its performance at the SPring-8 synchrotron X-ray light source. The TES spectrometer consists of a 240 pixel National Institute of Standards and…
We have fabricated Transition Edge Sensors (TESs) whose thermal characteristics are completely characterised by few-mode ballistic phonon exchange with the heat bath. These TESs have extremely small amorphous SiNx support legs: 0.2 um…