Related papers: Technical Note: A fast and monolithic prototype cl…
Objective. Proton beams enable localized dose delivery. Accurate range estimation is essential, but planning still relies on X-ray CT, which introduces uncertainty in stopping power and range. Proton CT measures water equivalent thickness…
A novel beam profiler based on microstructured scintillation resin is presented. The detector consists of a bundle of waveguides, with an active area of 30 x 30 mm$^2$ and a pitch of 400 $\mu$m, obtained by molding a scintillating resin…
We present prototype modules for a tracking detector consisting of multiple layers of 0.25 mm diameter scintillating fibers that are read out by linear arrays of silicon photomultipliers. The module production process is described and…
Purpose: The purpose of this work was to provide a flexible platform for FLASH research with protons by adapting a former clinical pencil beam scanning gantry to irradiations with ultrahigh dose rates. Methods: PSI Gantry 1 treated patients…
The fast scintillation decay time and the high scintillation yield of liquid xenon makes it an appropriate material for nuclear medicine. Moreover, being a continuous medium with a uniform response, liquid xenon allows one to avoid most of…
Objective. Prompt-gamma imaging encompasses several approaches for online monitoring of beam range or deposited dose distribution in proton therapy. We test one of the imaging techniques - a coded mask approach - both experimentally and via…
As a prototype detector for the SHiP Surrounding Background Tagger (SBT), we constructed a cell (120 cm x 80 cm x 25 cm) made from corten steel that is filled with liquid scintillator (LS) composed of linear alkylbenzene (LAB) and…
A novel modular high-resolution charged-particle tracking detector design using $250\mu m$ diameter, round, scintillating fibers and SiPM arrays for readout is presented. The fiber modules consist of 8 layers of 128 fibers, mechanically sta…
Purpose: Ultra-fast scintillation imaging has been shown to provide a unique tool for spatio-temporal dosimetry of conventional cyclotron and synchrocyclotron pencil beam scanning (PBS) deliveries, indicating the potential use for…
Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall…
The performance of a scintillating fiber detector prototype for tracking under high rate conditions is investigated. A spatial resolution of about100 micron is aimed for the detector. Further demands are low occupancy and radiation hardness…
The purpose of this study was to investigate the feasibility of extracting proton beams with two distinct energies within a single synchrotron cycle. The energy difference between the beams should be sufficient to use one beam as a range…
A new high-granular compact time-of-flight neutron detector for the identification and energy measurement of neutrons produced in nucleus-nucleus interactions at the BM@N experiment, Dubna, Russia, at energies up to 4 AGeV is under…
Photon counting CT (PCCT) has been a research focus in the last two decades. Recent studies and advancements have demonstrated that systems using semiconductor-based photon counting detectors (PCDs) have the potential to provide better…
Liquid xenon offers several features, which make it suitable for applications in nuclear medicine, such as high scintillation yield and fast scintillation decay time. Moreover, being a continuous medium with a uniform response, liquid xenon…
The results obtained in laboratory tests, using scintillator bars read by silicon photomultipliers are reported. The present approach is the first step for designing a precision tracking system to be placed inside a free magnetized volume…
In this work, the standard CsI(Tl) scintillator was used to determine the characteristics of a proton beam. By irradiating the scintillator with a proton beam, it was able to subsequently measure the emitted light using a spectrometer. This…
Liquid scintillating phantoms have been proposed as a means to perform real-time 3D dosimetry for proton therapy treatment plan verification. We have studied what effect radiation damage to the scintillator will have upon this application.…
In this study, we developed a new proton detector system called CATCH, which was designed for a scattering experiment involving a $\Sigma$ hyperon and a proton (J-PARC E40). CATCH is a cylindrical detector system covering an inner target…
Plastic scintillators are widely used for the detection of elementary particles, and 3D reconstruction of particle tracks is achieved by segmenting the detector into 3D granular structures. In this study, we present a novel prototype…