Related papers: Technical Note: A fast and monolithic prototype cl…
Silicon photomultipliers (SiPMs) are a good alternative to photomultiplier tubes (PMTs) because their gain and quantum efficiency are comparable to PMTs. However, the largest single-chip SiPM is still less than 1~cm$^2$. In order to use…
The power of the proton beam of a high-power spallation neutron source generally ranges from 100 kW to several MW. The distribution of the power density of the beam on the target is critical for the stable operation of the high-power…
Recently, shoot-through proton FLASH has been proposed where the highest energy is extracted from the cyclotron to maximize the dose rate (DR). Even though our proton pencil beam scanning system can deliver 250 MeV (the highest energy), it…
This master thesis presents a new type of Positron Emission TOF Apparatus using Liquid xenOn (PETALO). The detector is based in the Liquid Xenon Scintillating Cell (LXSC). The cell is a box filled with liquid xenon (LXe) whose transverse…
In the Energy Frontier we suggest developing high rate (100 MHz) finely segmented forward calorimetry preradiators with time resolution <50 ps which will survive the first 1-2 Lint of incident high radiation doses, protecting forward…
A novel and simple approach to optical wavelength measurement is presented in this paper. The working principle is demonstrated using a tunable waveguide micro ring resonator and single photodiode. The initial calibration is done with a set…
Neutron detection provides an effective method to detect, locate, and characterize sources of interest to nuclear security applications. Current neutron imaging systems based on double-scatter kinematic reconstruction provide good signal…
We report about the methods used in, and the performance of, the new fast and light-weight linear beam transport program MinT. MinT provides, beyond the usual linear ion optics, methods to compute the effects of beam degradation, multiple…
AIMS: Clinical radiographic imaging is seated upon the principle of differential keV photon transmission through an object. At clinical x-ray energies the scattering of photons causes signal noise and is utilized solely for transmission…
We propose a new scintillation-type detector in which high-energy radiation produces electron-hole pairs in a direct-gap semiconductor material that subsequently recombine producing infrared light to be registered by a photo-detector. The…
SOlar Neutron TRACking (SONTRAC) is a detector concept based on a bundle of plastic scintillators by aiming at tracking the solar neutrons through the generation of the secondary particles such as protons from the (n, np) and (n, p)…
Radiation detection is vital for space, medical imaging, homeland security, and environmental monitoring applications. In the past, the Monte Carlo radiation transport toolkit, Geant4, has been employed to enable the effective development…
We developed a beam telescope system comprising five layers of 300-$\mu$m-thick INTPIX4NA monolithic pixel sensors with each pixel size of 17 $\mu$m square. The sensors were fabricated using silicon-on-insulator (SOI) technology. The…
In this study, we have developed a new sub-MeV neutron detector that has a high position resolution, energy resolution, directional sensitivity, and low background. The detector is based on a super-fine-grained nuclear emulsion, called the…
A detector using liquid Xenon (LXe) in the scintillation mode is studied for Positron Emission Tomography (PET) of small animals. Its specific design aims at taking full advantage of the Liquid Xenon scintillation properties. This paper…
This paper focuses on some dosimetry aspects of proton therapy and pencil beam scanning based on the experience accumulated at Paul Scherrer Institute(PSI). The basic formalism for absolute dosimetry in proton therapy is outlined and the…
In this work, we report on the advantageous aspects of the i-TED Compton imager for proton-range monitoring, based on the results of the first Monte Carlo study of its applicability to this field. i-TED is an array of Compton cameras, that…
PETALO (Positron Emission TOF Apparatus with Liquid xenOn) is a project that uses liquid xenon as a scintillation medium, silicon photomultipliers as a readout and fast electronics to provide a significant improvement in PET-TOF technology.…
A neutron time projection chamber can locate the approximate direction of a neutron hot spot with high efficiency and a 4{\pi} field of view. The angular resolution can be significantly improved by adding several plastic scintillation…
A large area plastic scintillator detector array(~ 1 m x1m) has been set up for fast neutron spectroscopy at the BARC-TIFR Pelletron laboratory, Mumbai. The energy, time and position response has been measured for electrons using…