English
Related papers

Related papers: New Method for Silicon Sensor Charge Calibration U…

200 papers

X-ray detectors made of crystalline silicon have several advantages including low dark currents, fast charge collection and high energy resolution. For high-energy x-rays, however, silicon suffers from its low atomic number, which might…

Instrumentation and Detectors · Physics 2021-01-26 Moa Yveborg , Cheng Xu , Erik Fredenberg , Mats Danielsson

Absolute cross sections measured using electromagnetic devices to separate and detect heavy recoiling ions need to be corrected for charge state fractions. Accurate prediction of charge state distributions using theoretical models is not…

Good geometrical calibration is essential in the use of high resolution detectors. The individual sensors in the detector have to be calibrated with an accuracy better than the intrinsic resolution, which typically is of the order of 10 um.…

Data Analysis, Statistics and Probability · Physics 2009-09-29 V. Karimaki , A. Heikkinen , T. Lampen , T. Linden

Calibration of the absolute energy scale at high-energy photon (gamma-gamma, gamma-electron) colliders is discussed. The luminosity spectrum at photon colliders is broad and has a rather sharp high-energy edge, which can be used, for…

Accelerator Physics · Physics 2015-06-22 V. I. Telnov

MALTA2 is a depleted monolithic active pixel sensor (DMAPS) designed for tracking at high rates and typically low detection threshold of $\sim150\,\mathrm{e^-}$. A precise knowledge of the threshold is crucial to understanding the charge…

Scintillator detectors electronics is recalibrated against the datasheet given by the manufacturer. Optimal and mutual dependent values of (a) high voltage at PMT (Photomultiplier Tube), (b) amplifier gain, (c) average time to count the…

Instrumentation and Detectors · Physics 2023-03-07 Mayank Goswami , Kajal Kumari

The increase in the number of counterfeit and recycled microelectronic chips in recent years has created significant security and safety concerns in various applications. Hence, detecting such counterfeit chips in electronic systems is…

Cryptography and Security · Computer Science 2023-02-23 Maryam Saadat Safa , Tahoura Mosavirik , Shahin Tajik

Various chips for the silicon sensors measurements are described. These chips are based on 0.35 um and 0.18um CMOS technology. Several analog chips together with self-trigger /derandomizer one allow to measure silicon sensors designed for…

Instrumentation and Detectors · Physics 2009-10-13 E. Atkin , A. Kluev , A. Silaev , A. Fedenko , D. Karmanov , M. Merkin , A. Voronin

We have investigated the depletion voltage changes, the leakage current increase and the charge collection efficiency of a silicon microstrip detector identical to those used in the inner layers of the BaBar Silicon Vertex Tracker (SVT)…

Instrumentation and Detectors · Physics 2009-11-10 S. Bettarini , M. Bondioli , L. Bosisio , G. Calderini , C. Campagnari , S. Dittongo , F. Forti , M. A. Giorgi , G. Marchiori , G. Rizzo

Characterization measurements of $25~\mathrm{\mu m} \times 25~\mathrm{\mu m}$ pitch 3D silicon sensors are performed, for devices with active thickness of $150~\mu$m. Evidence of charge multiplication caused by impact ionization below the…

Instrumentation and Detectors · Physics 2024-11-19 Andrew Gentry , Maurizio Boscardin , Martin Hoeferkamp , Marco Povoli , Sally Seidel , Jiahe Si , Gian-Franco Dalla Betta

Hard X-ray photons with energies in the range of hundreds of keV typically undergo Compton scattering when they are incident on a detector. In this process, an incident photon deposits a fraction of its energy at the point of incidence and…

The quadrant silicon detector, a kind of passivated implanted planar silicon detector with quadrant structure on the junction side, gained its wide application in charged particle detection. In this paper, the manufacturing procedure,…

Instrumentation and Detectors · Physics 2015-06-18 Pengfei Bao , Chengjian Lin , Feng Yang , Zhaoqiao Guo , Tianshu Guo , Lei Yang , Lijie Sun , Huiming Jia , Xinxing Xu , Nanru Ma , Huanqiao Zhang , Zuhua Liu

Hybrid pixel single-photon-counting detectors have been successfully employed and widely used in Synchrotron radiation X-ray detection. In this paper, the silicon pixel sensors for single X-ray photon detection, which operate in…

Instrumentation and Detectors · Physics 2016-08-03 Zhen-Jie Li , Yun-Cong Jia , Ling-Fei Hu , Peng Liu , Hua-Xiang Yin

Switched capacitor arrays (SCA) ASICs are becoming more and more popular for the readout of detector signals, since the sampling frequency of typically several gigasamples per second allows excellent pile-up rejection and time measurements.…

Instrumentation and Detectors · Physics 2014-11-24 D. Stricker-Shaver , S. Ritt , B. J. Pichler

We summarize the R&D activities on a novel semitransparent microstrip sensor to be used on laser-based alignment systems for silicon trackers. The new sensor is used both for particle tracking and laser detection. The aim of this research…

Investigation of HV-CMOS sensors for use as a tracking detector in the ATLAS experiment at the upgraded LHC (HL-LHC) has recently been an active field of research. A potential candidate for a pixel detector built in Silicon-On-Insulator…

Instrumentation and Detectors · Physics 2017-10-27 B. Hiti , V. Cindro , A. Gorišek , T. Hemperek , T. Kishishita , G. Kramberger , H. Krüger , I. Mandić , M. Mikuž , N. Wermes , M. Zavrtanik

The Silicon Charge Detector (SCD) is a subdetector of the High Energy Cosmic Radiation Detection payload. The dynamic range of the silicon microstrip detector can be extended by the capacitive coupling effect, which is related to the…

Instrumentation and Detectors · Physics 2024-03-03 Ruo-Si Lu , Rui Qiao , Ke Gong , Wen-Xi Peng , Wei-Shuai Zhang , Dong-Ya Guo , Jia-Ju Wei , Yi-Ming Hu , Jian-Hua Guo , Qi Wu , Peng Hu , Xuan Liu , Bing Lu , Yi-Rong Zhang

The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…

Future high-resolution imaging X-ray observatories may require detectors with both fine spatial resolution and high quantum efficiency at relatively high X-ray energies (>5keV). A silicon imaging detector meeting these requirements will…

A method for calibration of cryogenic liquid argon detector response to recoils with certain energy -8.2 keV - is proposed. The method utilizes a process of inelastic scattering of monoenergetic neutrons produced by fusion DD neutron…

Instrumentation and Detectors · Physics 2014-07-11 Sergey Polosatkin , Evgeny Grishnyaev , Alexander Dolgov