Related papers: Non-rigid 3D motion estimation at high temporal re…
The MR-Linac is a combination of an MR-scanner and radiotherapy linear accelerator (Linac) which holds the promise to increase the precision of radiotherapy treatments with MR-guided radiotherapy by monitoring motion during radiotherapy…
Estimation of internal body motion with high spatio-temporal resolution can greatly benefit MR-guided radiotherapy/interventions and cardiac imaging, but remains a challenge to date. In image-based methods, where motion is indirectly…
Respiratory motion during radiotherapy causes uncertainty in the tumor's location, which is typically addressed by an increased radiation area and a decreased dose. As a result, the treatments' efficacy is reduced. The recently proposed…
We present a novel approach for the reconstruction of time-resolved free-running first-pass myocardial perfusion MRI, named CMR-MOTUS. This method builds upon the MR-MOTUS framework and addresses the challenges of a contrast varying…
Motion estimation of organs in a sequence of images is important in numerous medical imaging applications. The focus of this paper is the analysis of 4D Respiratory Correlated Computed Tomography (RCCT) Imaging. It is hypothesized that the…
Motion remains a major challenge in magnetic resonance (MR) imaging, particularly in free-breathing cardiac MR imaging, where data are acquired over multiple heartbeats at varying respiratory phases. We adopt a model-based approach for…
The reconstruction of 3D cine-MRI is challenged by highly undersampled k-space data in each cine frame, due to the slow speed of MR signal acquisition. We proposed a machine learning-based framework, spatial and temporal implicit neural…
We introduce an unsupervised motion-compensated image reconstruction algorithm for free-breathing and ungated 3D cardiac magnetic resonance imaging (MRI). We express the image volume corresponding to each specific motion phase as the…
Motion has been a challenge for magnetic resonance (MR) imaging ever since the MR has been invented. Especially in volumetric imaging of thoracic and abdominal organs, motion-awareness is essential for reducing motion artifacts in the final…
This study presents an unsupervised, motion-resolved reconstruction framework for high-resolution, free-breathing pulmonary magnetic resonance imaging (MRI), utilizing a three-dimensional Gaussian representation (3DGS). The proposed method…
Image quality of PET reconstructions is degraded by subject motion occurring during the acquisition. MR-based motion correction approaches have been studied for PET/MR scanners and have been successful at capturing regular motion patterns,…
A major challenge of the long measurement times in magnetic resonance imaging (MRI), an important medical imaging technology, is that patients may move during data acquisition. This leads to severe motion artifacts in the reconstructed…
Purpose: To develop a computationally viable autofocus method for estimating 3D rigid motion in MR imaging. Theory and Methods: The proposed method, REACT, assumes a piecewise-constant motion trajectory and estimates the rigid motion…
Purpose: To develop a reconstruction framework for 3D real-time cine cardiovascular magnetic resonance (CMR) from highly undersampled data without requiring fully sampled training datasets. Methods: We developed a multi-dynamic low-rank…
We propose a novel low-rank tensor method for respiratory motion-resolved multi-echo image reconstruction. The key idea is to construct a 3-way image tensor (space $\times$ echo $\times$ motion state) from the conventional gridding…
Modeling of respiratory motion is important for a more accurate understanding and accounting of its effect on dose to cancers in the thorax and abdomen by radiotherapy. We have developed a model of respiration-induced organ motion in the…
Four-dimensional MRI (4D-MRI) is an promising technique for capturing respiratory-induced motion in radiation therapy planning and delivery. Conventional 4D reconstruction methods, which typically rely on phase binning or separate template…
Conventional cardiovascular magnetic resonance (CMR) cine imaging relies on binning multiple heartbeats into a single cardiac cycle, which fails in arrhythmic patients where beat-to-beat variability causes motion artifacts and loss of…
Based on a 3D pre-treatment magnetic resonance (MR) scan, we developed DREME-MR to jointly reconstruct the reference patient anatomy and a data-driven, patient-specific cardiorespiratory motion model. Via a motion encoder simultaneously…
Physiological motion, such as cardiac and respiratory motion, during Magnetic Resonance (MR) image acquisition can cause image artifacts. Motion correction techniques have been proposed to compensate for these types of motion during…