Purpose: To present the performance of a multi-point plastic scintillation detector (mPSD) as a tool in vivo dosimetry in brachytherapy. Methods: A previously optimized three-point sensor system was used for in vivo HDR brachytherapy…

Medical Physics · Physics 2021-01-27 Haydee M. Linares Rosales , Louis Archambault , Sam Beddar , Luc Beaulieu

Since large dose are administrated to the patient in brachytherapy treatment, ensuring the right dose is delivered is highly critical. This study presents a first step in solving the standing issue of accurately knowing the dosimeter…

Medical Physics · Physics 2018-12-27 Daline Tho , Luc Beaulieu

This study aims to introduce IViST (In Vivo Source Tracking), a novel multi-sensors dosimetry platform for real-time treatment monitoring in HDR brachytherapy. IViST is a platform that comprises 3 parts: 1) an optimized and characterized…

Medical Physics · Physics 2020-06-16 Haydee M. Linares Rosales , Audrey Cantin , Sylviane Aubin , Sam Beddar , Luc Beaulieu

Purpose: We introduce a novel concept of a compact multiprobe scintillator detector and demonstrate its applicability in HDR-brachytherapy. Our fabricated seven-probe system is sufficiently narrow to be inserted in a brachytherapy needle or…

Purpose: We sought to evaluate the feasibility of using machine learning algorithms for multipoint plastic scintillator detector calibration in high-dose-rate brachytherapy. Methods: The dosimetry system consisted of an optimized 1-mm-core…

Purpose: HDR brachytherapy is a widely adopted modality for cancer treatment. However, it is not free from error and uncertainty. In-vivo dosimetry (IVD) is the only technique that can confirm correct dose delivery. This study details and…

Medical Physics · Physics 2025-12-10 Chahrazed Ghannoudi , Marie-Claude Lavallee , Benjamin Cote , Luc Beaulieu

Purpose: This study aims to optimize and characterize the response of a mPSD for in vivo dosimetry in HDR brachytherapy. Methods: An exhaustive analysis was carried out in order to obtain an optimized mPSD design that maximize the…

Background: Ultra-high dose rate proton therapy shows promise in tissue sparing by enhancing therapeutic ratio through the FLASH effect. In radiotherapy, accurate in vivo dosimetry is crucial for quality assurance, but remains challenging…

Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional…

Medical Physics · Physics 2021-09-22 Emily Cloutier , Louis Archambault , Luc Beaulieu

The increasing interest in FLASH-RT has lead to the conversion of linear accelerators to enable ultra-high dose rate (UHDR) beams for preclinical research. Dosimetry hereof remains challenging with several crucial aspects missing. This work…

{\bf Purpose:} This study evaluates a compact biocompatible Seven-probe Scintillator Detector (7SD) for monitoring HDR-BT treatment sequences across a range of dwell times and source-probe spacings representative of most HDR-BT techniques.…

FLASH-RT has proven beneficial in preclinical studies. However, the lack of accurate real time 2D dosimetry is a limiting factor. In this work, an innovative solution for 2D real time dosimetry in UHDR electron beams is presented. The…

Background: In vivo dosimetry is essential for treatment verification in modern radiotherapy, but existing techniques are limited by spatiotemporal resolution and performance on non-uniform anatomy. Scintillation imaging dosimetry shows…

The reconstruction of particle trajectories makes it possible to distinguish between different types of charged particles. In high-energy physics, where trajectories are rather long, large size trackers must be used to achieve sufficient…

Anatomical motion and deformation pose challenges to the understanding of the delivered dose distribution during radiotherapy treatments. Hence, deformable image registration (DIR) algorithms are increasingly used to map contours and dose…

Medical Physics · Physics 2021-09-22 Emily Cloutier , Luc Beaulieu , Louis Archambault

Introduction: Real-time dosimetry of surface doses in electron beams has not been widely established yet. Plastic scintillation detectors (PSD) promise high spatial resolution and real-time dosimetry with minimum perturbation of the…

Background: Scintillation dosimetry has promising qualities for ultra-high dose rate (UHDR) radiotherapy (RT), but no system has shown compatibility with mean dose rates ($\bar{DR}$) above 100 Gy/s and doses per pulse ($D_p$) exceeding 1.5…

Medical Physics · Physics 2024-03-06 Alexander Baikalov , Daline Tho , Kevin Liu , Stefan Bartzsch , Sam Beddar , Emil Schüler

Ultra-high dose rate electron sources require dose rate independent dosimeters and a calibrated dose control system for accurate delivery. In this study, we developed a single-pulse dose monitoring and a real-time dose-based control system…

Purpose: For more than a decade that plastic optical fiber based dosimeters have been developed for medical applications. The feasibility of dosimeters using optical fibers that are almost Cherenkov light free has been demonstrated in some…

Medical Physics · Physics 2011-09-30 Florbela Rêgo , Luis Peralta , Maria da Conceição Abreu

Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present…