English
Related papers

Related papers: 3D source tracking and error detection in HDR usin…

200 papers

Using a series of detector measurements taken at different locations to localize a source of radiation is a well-studied problem. The source of radiation is sometimes constrained to a single point-like source, in which case the location of…

Instrumentation and Detectors · Physics 2021-10-06 M. S. Bandstra , D. Hellfeld , J. R. Vavrek , B. J. Quiter , K. Meehan , P. J. Barton , J. W. Cates , A. Moran , V. Negut , R. Pavlovsky , T. H. Y. Joshi

The $^{192}$Ir sources are widely used for high dose rate (HDR) brachytherapy treatments. The aim of this study is to simulate $^{192}$Ir MicroSelectron v2 HDR brachytherapy source and calculate the air kerma strength, dose rate constant,…

Medical Physics · Physics 2016-01-14 Hamza Naeem , Chaobin Chen , Huaqing Zheng , Ruifen Cao , Xi Pei , Liqin Hu , Yican Wu

Purpose: A diode EDGE Detector with a newly designed electrometer has been characterized for use in an UHDR electron beam and demonstrated appropriateness for UHDR FLASH radiotherapy dosimetry. Methods: Dose linearity, mean dose rate, and…

The FLASH effect holds significant potential in improving radiotherapy treatment outcomes. Very high energy electrons (VHEEs) can effectively target tumors deep in the body and can be accelerated to achieve ultra-high dose rates (UHDR),…

Background: The normal tissue sparing effect of ultra-high dose rate irradiation (>40 Gy/s, UHDR), as compared to conventional dose rate (CONV), has attracted significant research interest for FLASH radiotherapy (RT). Accurate, dose rate…

Medical Physics · Physics 2025-07-08 Lixiang Guo , Banghao Zhou , Yi-Chun Tsai , Kai Jiang , Viktor Iakovenko , Ken Kang-Hsin Wang

One major challenge for 3D pose estimation from a single RGB image is the acquisition of sufficient training data. In particular, collecting large amounts of training data that contain unconstrained images and are annotated with accurate 3D…

Computer Vision and Pattern Recognition · Computer Science 2016-03-29 Hashim Yasin , Umar Iqbal , Björn Krüger , Andreas Weber , Juergen Gall

This study presents the development and validation of an independent software tool based on the Varian Eclipse Scripting API (ESAPI) for multi-modal brachytherapy Quality Assurance (QA). The tool addresses GEC-ESTRO HDR protocols and LDR…

Medical Physics · Physics 2026-03-24 J. A. Valgoma

This paper proposes a method for detecting multiple scatterers (targets) in the elevation direction for synthetic aperture radar (SAR) tomography. The proposed method can resolve closely spaced targets through a twostep procedure. In the…

Information Theory · Computer Science 2022-04-11 Ahmad Naghavi , Mohammad Sadegh Fazel , Mojtaba Beheshti , Ehsan Yazdian

In this work we explored the use of patient specific reinforced learning to generate 3D activity maps from two 2D planar images (anterior and posterior). The solution of this problem remains unachievable using conventional methodologies and…

A novel data-processing method was developed to facilitate scintillation detector characterization. Combined with fan-beam calibration, this method can be used to quickly and conveniently calibrate gamma-ray detectors for SPECT, PET,…

Instrumentation and Detectors · Physics 2021-06-24 Xin Li , Li Tao , Craig S. Levin , Lars R. Furenlid

The results obtained in laboratory tests, using scintillator bars read by silicon photomultipliers are reported. The present approach is the first step for designing a precision tracking system to be placed inside a free magnetized volume…

Instrumentation and Detectors · Physics 2017-01-04 S. Cecchini , I. D'Antone , L. Degli Esposti , I. Lax , G. Mandrioli , N. Mauri , L. Pasqualini , L. Patrizii , M. Pozzato , G. Sirri , M. Tenti

This study introduces the HYPERSCINT research platform, the first commercially available scintillation dosimetry platform capable of multi-point dosimetry through the hyperspectral approach. Optic and dosimetric performances of the system…

Instrumentation and Detectors · Physics 2021-04-19 Emilie Jean , Francois Therriault-Proulx , Luc Beaulieu

Plastic scintillator detectors with three-dimensional granularity and sub-nanosecond time resolution offer simultaneous particle tracking, identification, and calorimetry. However, scaling to larger volumes and finer segmentation poses…

Instrumentation and Detectors · Physics 2024-12-31 Umut Kose

Radiation detection has largely been a manual inspection process with point sensors such as Geiger-Muller counters and scintillation spectrometers to date. While their observations of source proximity prove useful, they lack the directional…

Robotics · Computer Science 2018-04-05 Michael S. Lee , Matthew Hanczor , Jiyang Chu , Zhong He , Nathan Michael , Red Whittaker

This paper presents a non-parametric method for 3-D imaging of natural volumes using Synthetic Aperture Radar tomography. This array processing-based technique aims at characterizing a spatially distributed density of incoherent sources,…

Signal Processing · Electrical Eng. & Systems 2025-03-18 Colin Cros , Laurent Ferro-Famil

Purpose: Ultra-fast scintillation imaging has been shown to provide a unique tool for spatio-temporal dosimetry of conventional cyclotron and synchrocyclotron pencil beam scanning (PBS) deliveries, indicating the potential use for…

Purpose: To determine whether alternative HDR prostate brachytherapy catheter patterns can result in improved dose distributions while providing better access and reducing trauma. Methods: Prostate HDR brachytherapy uses a grid of parallel…

Medical Physics · Physics 2015-05-13 J. Adam M. Cunha , I-Chow Hsu , Jean Pouliot

A new approach to three-dimensional (3D) dosimetry based on optically-stimulated luminescence (OSL) is presented. By embedding OSL-active particles into a transparent silicone matrix (PDMS), the well-established dosimetric properties of an…

Gamma sources are routinely used to calibrate the energy scale and resolution of liquid scintillator detectors. However, non-scintillating material surrounding the source introduces energy losses, which may bias the determination of the…

Instrumentation and Detectors · Physics 2021-09-01 Feiyang Zhang , Rui Li , Jiaqi Hui , Jianglai Liu , Yue Meng , Yuanyuan Zhang

Purpose: This work describes the development and pilot implementation of a comprehensive remote dosimetry audit for Ir-192 high-dose-rate interstitial brachytherapy, integrating independent experimental and computational dosimetry within a…