Related papers: 200 mm Sensor Development Using Bonded Wafers
CMOS Pixel Sensors tend to become relevant for a growing spectrum of charged particle detection instruments. This comes mainly from their high granularity and low material budget. However, several potential applications require a higher…
The High Luminosity upgrade of the CERN Large Hadron Collider (HL-LHC) requires new high-radiation tolerant silicon pixel sensors for the innermost part of the tracking detector in the CMS experiment. The innermost layer of the tracker,…
As part of its HL-LHC upgrade program, the CMS collaboration is replacing its existing endcap calorimeters with a high-granularity calorimeter (CE). The new calorimeter is a sampling calorimeter with unprecedented transverse and…
The CMS Collaboration is preparing to build replacement endcap calorimeters for the HL-LHC era. The new high-granularity calorimeter (HGCAL) is, as the name implies, a highly-granular sampling calorimeter with approximately six million…
A new generation of 3D silicon pixel detectors with a small pixel size of 50$\times$50 and 25$\times$100 $\mu$m$^{2}$ is being developed for the HL-LHC tracker upgrades. The radiation hardness of such detectors was studied in beam tests…
The tracking detector of ATLAS, one of the experiments at the Large Hadron Collider (LHC), will be upgraded in 2024-2026 to cope with the challenging environment conditions of the High Luminosity LHC (HL-LHC). The LPNHE, in collaboration…
Pixel detectors are used in the innermost part of multi purpose experiments at the Large Hadron Collider (LHC) and are therefore exposed to the highest fluences of ionising radiation, which in this part of the detectors consists mainly of…
The depleted CMOS sensors are emerging as one of the main candidate technologies for future tracking detectors in high luminosity colliders. Its capability of integrating the sensing diode into the CMOS wafer hosting the front-end…
The High Luminosity upgrade of the CERN Large Hadron Collider will be able to reach a peak instantaneous luminosity of 5E34/cm2 s. The innermost detectors of the CMS and ATLAS experiments will have to cope with unprecedented requirements on…
The existing ATLAS Tracker will be at its functional limit for particle fluences of 10^15 neq/cm^2 (LHC). Thus for the upgrades at smaller radii like in the case of the planned Insertable B-Layer (IBL) and for increased LHC luminosities…
The high integration density of MAPS, with silicon sensor and readout electronics implemented in the same device, allows very thin structures with a greatly reduced material budget. Thicknesses of $\mathcal{O}$(50~$\mu$m), values at which…
We describe technologies which can be developed to produce large area, low cost pixelated tracking detec- tors. These utilize wafer-scale 3D electronics and sensor technologies currently being developed in industry. This can result in fully…
The ALICE collaboration is preparing an upgrade of the three innermost layers of the current Inner Tracking System (ITS) during the next LHC long shutdown (LS3). The new ITS detector will use wafer-scale (up to \SI{27}{cm} in length)…
Significant progress has been made to develop silicon pixel technologies for use in the vertex and tracker regions of the proposed Compact Linear Collider (CLIC) detector design. The electron-positron collisions generated by this linear…
With an expected ten-fold increase in luminosity in S-LHC, the radiation environment in the tracker volumes will be considerably harsher for silicon-based detectors than the already harsh LHC environment. Since 2006, a group of CMS…
The physics aims at the proposed future high-energy linear $e^+e^-$ collider CLIC pose challenging demands on the performance of the detector system. In particular, the vertex and tracking detectors have to combine a spatial resolution of a…
For the construction of the ATLAS Inner Tracker strip detector, silicon strip sensor modules are glued directly onto carbon fibre support structures using a soft silicone gel. During tests at temperatures below \unit[-35]{$^{\circ}$C},…
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $\mu$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot…
After the Large Hadron Collider (LHC) upgrade into High Luminosity LHC (HL-LHC), the instantaneous luminosity is expected to reach values up to 7.5x10^34cm^2/s, causing a harsher radiation environment as well as a significant increase in…
The next upgrade of the Large Hadron Collider (LHC) is planned from 2026 when the collider will move to its High Luminosity phase (HL-LHC). The CMS detector needs to be substantially upgraded during this period to exploit the fourfold…