Related papers: Thermal Kinetic Inductance Detectors for millimete…
Terahertz and sub-terahertz band detection has a key role both in fundamental interactions physics and technological applications, such as medical imaging, industrial quality control and homeland security. In particular, transition edge…
Cryogenic phonon detectors are adopted in experiments searching for dark matter interactions or coherent elastic neutrino-nucleus scattering, thanks to the low energy threshold they can achieve. The phonon-mediated sensing of particle…
We evaluate the performance of hybrid microwave resonators made by combining sputtered Nb thin films with Tungsten nanowires grown with a He-beam induced deposition technique. Depending on growth conditions the nanowires have a typical…
We develop Johnson noise thermometry applicable to mesoscopic devices with variable source impedance with high bandwidth for fast data acquisition. By implementing differential noise measurement and two-stage impedance matching, we…
Fast, room temperature imaging at THz and sub-THz frequencies is an interesting feature which could unleash the full potential of plenty applications in security, healthcare and industrial production. In this Letter we introduce…
Context. Millimetre-wave astronomy is an important tool for both general astrophysics studies and cosmology. A large number of unidentified sources are being detected by the large field-of-view continuum instruments operating on large…
Mapping the polarization of the Cosmic Microwave Background is yielding exciting data on the origin of the universe, the reionization of the universe, and the growth of cosmic structure. Kilopixel arrays represent the current state of the…
We have developed preamplifier configurations used to readout resistive bolometers such as those based on Neutron Transmuted Doped Germanium thermometers (so called NTD Ge thermometers)[1] or NbSi thin film thermometers [2, 3]. We introduce…
A noiseless, photon counting detector, which resolves the energy of each photon, could radically change astronomy, biophysics and quantum optics. Superconducting detectors promise an intrinsic resolving power at visible wavelengths of…
Microwave Kinetic Inductance Detectors, or MKIDs, have proven to be a powerful cryogenic detector technology due to their sensitivity and the ease with which they can be multiplexed into large arrays. A MKID is an energy sensor based on a…
Superconducting thin films with high intrinsic kinetic inductance $L_{k}$ are important for high-sensitivity detectors, enabling strong coupling in hybrid quantum systems, and enhancing nonlinearities in quantum devices. We report the…
We report on the performance of lumped--elements Kinetic Inductance Detector (KID) arrays for mm and sub--mm wavelengths, operated at 0.3K during the stratospheric flight of the OLIMPO payload, at an altitude of 37.8 km. We find that the…
A wide-bandwidth and low-noise amplification chain in the microwave regime is crucial for the efficient read-out of quantum systems based on superconducting detectors, such as Microwave Kinetic Inductance Detectors (MKIDs), Transition Edge…
We present our current progress on the design and test of Ti/TiN Multilayer for use in Kinetic Inductance Detectors (KIDs). Sensors based on sub-stoichiometric TiN film are commonly used in several applications. However, it is difficult to…
A prototype version of the Q & U bolometric interferometer for cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology laboratory in Paris (APC). The detection chain is currently made of…
We report here the first RF noise measurements on two designs of n-doped GaN/AlN double-barrier resonant tunneling diodes (RTDs), each having a room-temperature negative differential resistance (NDR) and also strong near-UV light emission.…
Kinetic inductance traveling-wave parametric amplifiers (KI-TWPA) have a wide instantaneous bandwidth with near quantum-limited performance and a relatively high dynamic range. Because of this, they are suitable readout devices for…
The Lumped Element Kinetic Inductance Detectors (LEKID)demonstrated full maturity in the NIKA (New IRAM KID Arrays)instrument. These results allow directly comparing LEKID performance with other competing technologies (TES, doped silicon)…
We have developed two analytical models to describe the performance of cryogenic microcalorimeters and bolometers. One of the models is suitable to describe Transition Edge Sensor (TES) detectors with an integrated absorber, the other is…
We present a method of spatially mapping microwave kinetic inductance detector (MKID) arrays, in a dark setup. MKIDs are superconducting natively multiplexed resonators which enable kilopixel arrays, such as for the proposed Probe…