Related papers: Thermal Kinetic Inductance Detectors for millimete…
We introduce a microwave bolometer aimed at high-quantum-efficiency detection of wave packet energy within the framework of circuit quantum electrodynamics, the ultimate goal being single microwave photon detection. We measure the…
Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a powerful new tool for single photon detection. These highly multiplexed superconducting devices give timing and energy measurement for every detected photon. However,…
We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a…
The next generation BLAST experiment (BLAST-TNG) is a suborbital balloon payload that seeks to map polarized dust emission in the 250 $\mu$m, 350 $\mu$m and 500 $\mu$m wavebands. The instrument utilizes a stepped half-wave plate to reduce…
This work intends to give the state-of-the-art of our knowledge of the performance of LEKIDs at millimetre wavelengths (from 80 to 180~GHz). We evaluate their optical sensitivity under typical background conditions and their interaction…
The latest generation of cosmic microwave background (CMB) telescopes is searching for the undetected faint signature of gravitational waves from inflation in the polarized signal of the CMB. To achieve the unprecedented levels of…
Thermal-radiation detectors such as bolometers -- often found as thin, suspended films -- are intrinsically limited by their optical absorption properties and by their intrinsic thermal conductive and radiative losses. We analyze the impact…
Microwave Kinetic Inductance Detectors (MKIDs) are superconducting detectors capable of counting single photons and measuring their energy in the UV, optical, and near-IR. MKIDs feature intrinsic frequency domain multiplexing (FDM) at…
As superconducting kinetic inductance detectors (KIDs) continue to grow in popularity for sensitive submillimeter detection and other applications, there is a drive to advance toward lower-loss devices. We present measurements of diagnostic…
We study the mechanism of instability in transition edge sensor (TES) bolometers used for ground based observations of the Cosmic Microwave Background (CMB) at 270GHz. The instability limits the range of useful operating resistances of the…
For space observatories, the glitches caused by high energy phonons created by the interaction of cosmic ray particles with the detector substrate lead to dead time during observation. Mitigating the impact of cosmic rays is therefore an…
Following optical pulses ($\lambda=405~\text{nm}$) on titanium nitride (TiN) Microwave Kinetic Inductance Detectors (MKIDs) cooled down at temperatures $T \le T_c / 20$ ($T_c \simeq 4.6~\text{K}$), we observe a large phase-response…
We report photon-noise limited performance of horn-coupled, aluminum lumped-element kinetic inductance detectors at millimeter wavelengths. The detectors are illuminated by a millimeter-wave source that uses an active multiplier chain to…
Kinetic Inductance Detectors (KIDs) are superconducting energy-resolving detectors, sensitive to single photons from the near-infrared to ultraviolet. We study a hybrid KID design consisting of a beta phase tantalum ($\beta$-Ta) inductor…
We design a superconducting thermoelectric bolometer made of a Graphene-Insulator-Superconductor tunnel junction. Our detector has the advantage of being passive, as it directly transduces input power to a voltage without the need to…
Low mechanical loss materials are needed to further decrease thermal noise in upcoming gravitational wave detectors. We present an analysis of the contribution of Akhieser and thermoelastic damping on the experimental results of resonant…
Thermal voltage noise measurements are performed in order to determine the electron temperature in nanopatterned channels of a GaAs/AlGaAs heterostructure at bath temperatures of 4.2 and 1.4 K. Two narrow two-dimensional (2D) heating…
Most microwave readout architectures in quantum computing or sensing rely on a semiconductor amplifier at 4 K, typically a high-electron mobility transistor (HEMT). Despite its remarkable noise performance, a conventional HEMT dissipates…
Nanoelectromechanical (NEMS) resonators are promising uncooled thermal infrared (IR) detectors to overcome existing sensitivity limits. Here, we investigated nanoelectromechanical trampoline resonators made of silicon nitride (SiN) as…
We present a detailed simulation and design framework for realizing traveling wave parametric amplifiers (TWPAs) using the nonlinear kinetic inductance of disordered superconductors -- in our case niobium-titanium-nitride (NbTiN). These…