English
Related papers

Related papers: Thermal Kinetic Inductance Detectors for millimete…

200 papers

A vacuum compatible cryogenic accelerometer is presented which will reach $<0.5$ p$g$ Hz$^{-1/2}$ sensitivity from 1 mHz to 10 Hz with a maximum sensitivity of 10 f$g$ Hz$^{-1/2}$ around 10 Hz. This figure can be translated to a…

Applied Physics · Physics 2020-08-26 Joris Vincent van Heijningen

In Kinetic Inductance Detectors (KIDs) and other similar applications of superconducting microresonators, both the large and small-signal behaviour of the device may be affected by electrothermal feedback. Microwave power applied to read…

Instrumentation and Methods for Astrophysics · Physics 2017-05-17 T. Guruswamy , C. N. Thomas , S. Withington , D. J. Goldie

Future measurements of the millimeter-wavelength sky require a low-loss superconducting microstrip, typically made from niobium and silicon-nitride, coupling the antenna to detectors. We propose a simple device for characterizing these…

Instrumentation and Methods for Astrophysics · Physics 2022-12-14 J. Hood , P. Barry , T. Cecil , C. Chang , S. Meyer , J. Li , Z. Pan , E. Shirokoff , A. Tang

The BULLKID-DM experiment aims to detect WIMP-like potential Dark Matter particles with masses below 1 GeV/c^2. Sensing these particles is challenging, as it requires nuclear recoil detectors characterized by high exposure and an energy…

A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector, and its principle is based on a superconducting resonator circuit. The superconducting transition temperature (Tc) of the MKID is an important…

Instrumentation and Detectors · Physics 2020-05-19 Hiroki Kutsuma , Yoshinori Sueno , Makoto Hattori , Satoru Mima , Shugo Oguri , Chiko Otani , Junya Suzuki , Osamu Tajima

We report on the development of scalable prototype microwave kinetic inductance detector (MKID) arrays tailored for future multi-kilo-pixel experiments that are designed to simultaneously characterize the polarization properties of both the…

This paper introduces a thermal infrared detector utilizing a nano-optomechanical silicon nitride (SiN) resonator, equipped with a free-space impedance-matched (FSIM) absorber composed of a platinum (Pt) thin film, offering a broadband…

Instrumentation and Detectors · Physics 2025-05-12 Paolo Martini , Stefan Emminger , Kostas Kanellopulos , Niklas Luhmann , Markus Piller , Robert Greyson West , Silvan Schmid

We are developing lumped-element kinetic inductance detectors (LEKIDs) designed to achieve background-limited sensitivity for far-infrared (FIR) spectroscopy on a stratospheric balloon. The Spectroscopic Terahertz Airborne Receiver for…

Instrumentation and Methods for Astrophysics · Physics 2018-05-23 S. Hailey-Dunsheath , A. C. M. Barlis , J. E. Aguirre , C. M. Bradford , J. G. Redford , T. S. Billings , H. G. LeDuc , C. M. McKenney , M. I. Hollister

The PRobe far-Infrared Mission for Astrophysics (PRIMA) is under study as a potential far-IR space mission, featuring actively cooled optics, and both imaging and spectroscopic instrumentation. To fully take advantage of the low background…

Microwave Kinetic Inductance Detectors (MKIDs) are a class of superconducting cryogenic detectors that simultaneously exhibit energy resolution, time resolution and spatial resolution. The pixel yield of MKID arrays is usually a critical…

Instrumentation and Methods for Astrophysics · Physics 2023-01-20 Mario De Lucia , E. Baldwin , G. Ulbricht , J. D. Piercy , O. Creaner , C. Bracken , T. P. Ray

The kinetic inductance detector (KID) is a versatile and scalable detector technology with a wide range of applications. These superconducting detectors offer significant advantages: simple and robust fabrication, intrinsic multiplexing…

Instrumentation and Detectors · Physics 2022-03-31 Peter S. Barry , Clarence. C. Chang , Sunil Golwala , Erik Shirokoff

The complex conductivity of a superconducting thin film is related to the quasiparticle density, which depends on the physical temperature and can also be modified by external pair breaking with photons and phonons. This relationship forms…

Instrumentation and Methods for Astrophysics · Physics 2023-04-04 G. Wang , P. S. Barry , T. Cecil , C. L. Chang , J. Li , M. Lisovenko , V. Novosad , Z. Pan , V. G. Yefremenko , J. Zhang

Microwave kinetic inductance detector (MKID) provides a way to build large ground based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good…

Instrumentation and Methods for Astrophysics · Physics 2016-02-15 L. Bisigello , S. J. C. Yates , V. Murugesan , J. J. A. Baselmans , A. M. Baryshev

Providing a background discrimination tool is crucial for enhancing the sensitivity of next-generation experiments searching for neutrinoless double- beta decay. The development of high-sensitivity (< 20 eV RMS) cryogenic light detectors…

We describe a kinetic inductance traveling-wave (KIT) amplifier suitable for superconducting quantum information measurements and characterize its wideband scattering and noise properties. We use mechanical microwave switches to calibrate…

We present measurements of the low-frequency noise of microstrip-coupled, lumped-element aluminum kinetic inductance detectors that use hydrogenated amorphous silicon parallel-plate capacitors (Al/a-Si:H MS-PPC-LEKIDs), which are under…

We describe the on-line algorithms developed to probe Lumped Element Kinetic Inductance Detectors (LEKID) in this paper. LEKIDs are millimeter wavelength detectors for astronomy. LEKID arrays are currently operated in different instruments…

A quantum-limited amplification chain is a fundamental advantage for any application that may benefit from the detection of very faint signals. Reading out arrays of superconducting detectors (TESs or MKIDs), resonant cavities, or qubits,…

The next generation of bolometric experiments searching for rave events, in particular for the neutrino-less double beta decay, needs fast, high-sensitivity and easy-to-scale cryogenic light detectors. The CALDER project (2014-2020)…

Detection of sub-GeV dark matter candidates requires sub-keV detector thresholds on deposited energy. We provide an update on a gram-scale phonon-mediated KID-based device that was designed for a dark matter search in this mass range at the…

Instrumentation and Detectors · Physics 2022-08-10 Osmond Wen , Taylor Aralis , Ritoban Basu Thakur , Bruce Bumble , Yen-Yung Chang , Karthik Ramanathan , Sunil Golwala
‹ Prev 1 3 4 5 6 7 10 Next ›