Related papers: Bone Material Analogues for PET/MRI Phantoms
Industry standards require medical device manufacturers to perform implant-induced artefact testing in phantoms at a pre-clinical stage to define the extent of artefacts that can be expected during MRI. Once a device is commercially…
In this work, we perform direct material reconstruction from spectral CT data using a model based iterative reconstruction (MBIR) approach. Material concentrations are measured in volume fractions, whose total is constrained by a maximum of…
Magnetic Resonance Imaging (MRI) is increasingly incorporated into treatment planning, because of its superior soft tissue contrast used for tumor and soft tissue delineation versus computed tomography (CT). However, MRI cannot directly…
Significance: Optical imaging of blood oxygenation (sO$_2$) can be achieved based on the differential absorption spectra of oxy- and deoxy-haemoglobin. A key challenge in realising clinical validation of the sO$_2$ biomarkers is the absence…
With the increasing complexity of external beam therapy, so-called "end-to-end" tests are intended to cover all steps from therapy planning to follow-up to fulfill the high demands on quality assurance. As magnetic resonance imaging (MRI)…
Anatomically guided PET reconstruction using MRI information has been shown to have the potential to improve PET image quality. However, these improvements are limited to PET scans with paired MRI information. In this work we employed a…
Purpose: To develop the Ultimate Phantom Dog for Orthovoltage Glioma Treatment (UPDOG), an anatomically-correct phantom which mimics a dog's head, for quality assurance (QA) of kilovoltage (kV) radiotherapy treatments. Methods: A computed…
Attenuation correction is an essential requirement of positron emission tomography (PET) image reconstruction to allow for accurate quantification. However, attenuation correction is particularly challenging for PET-MRI as neither PET nor…
In silico testing of implant materials is a research area of high interest, as cost- and labour-intensive experiments may be omitted. However, assessing the tissue-material interaction mathematically and computationally can be very complex,…
Objective: To perform a comprehensive comparative analysis of proton, helium-ion, and carbon-ion computed tomography (CT) as direct imaging modalities for hadron therapy treatment planning, focusing on Relative Stopping Power (RSP)…
Ultrasound imaging of the cortex of long bones may enable the measurement of the cortical thickness and the ultrasound wave speed in cortical bone tissue. However, with bone loss, the cortical porosity and the size of the pores increase,…
Purpose: To demonstrate an ultrashort echo time magnetic resonance fingerprinting (UTE-MRF) method that can simultaneously quantify tissue relaxometries for muscle and bone in musculoskeletal systems and tissue components in brain and…
Total-Body PET (TB-PET) scanners represent a significant advancement in medical diagnostics, exemplified by the uEXPLORER, the world's first TB-PET system with an axial span of 194 cm, which exhibits exceptional sensitivity and spatial…
The ability to synthesise Computed Tomography images - commonly known as pseudo CT, or pCT - from MRI input data is commonly assessed using an intensity-wise similarity, such as an L2-norm between the ground truth CT and the pCT. However,…
A major remaining challenge for magnetic resonance-based attenuation correction methods (MRAC) is their susceptibility to sources of MRI artifacts (e.g. implants, motion) and uncertainties due to the limitations of MRI contrast (e.g.…
Intraoperative Gamma Probe (IPG) remains the current gold standard modality for sentinel lymph node identification and tumor removal in cancer patients. However, even alongside the optical dyes they do not meet with <5% false negative rates…
Positron Emission Tomography (PET) is a functional imaging modality widely used in neuroscience studies. To obtain meaningful quantitative results from PET images, attenuation correction is necessary during image reconstruction. For PET/MR…
Low-dose Positron Emission Tomography (PET) imaging presents a significant challenge due to increased noise and reduced image quality, which can compromise its diagnostic accuracy and clinical utility. Denoising diffusion probabilistic…
Quantitative PET attenuation correction (AC) for combined cardiac PET/MR is a challenging problem. We propose and evaluate an AC approach that uses coincidences from a relatively weak and physically fixed sparse external source, in…
With X-ray radiation protection and dose management constantly gaining interest in interventional radiology, novel procedures often undergo prospective dose studies using anthropomorphic phantoms to determine expected dose values. Due to…