Related papers: Performance study of a Time of Flight Method used …
The Time-of-Flight (TOF) system of the AMS detector gives the fast trigger to the read out electronics and measures velocity, direction and charge of the crossing particles. The new version of the detector (called AMS-02) will be installed…
We present the results of the first high-altitude balloon flight test of a concept for an advanced Compton telescope making use of modern scintillator materials with silicon photomultiplier (SiPM) readouts. There is a need in the fields of…
The AMS-02 detector is a superconducting magnetic spectrometer that will operate on the International Space Station. The time of flight (TOF) system of AMS-02 is composed by four scintillator planes with 8, 8, 10, 8 counters each, read at…
The advent of silicon photomultipliers has enabled big advances in high energy physics instrumentation, for example by allowing the construction of extremely granular hadronic calorimeters with photon sensors integrated into small…
We present a method for the reconstruction of ion kinetic energy distributions from ion time-of-flight mass spectra through ion trajectory simulations. In particular, this method is applicable to complicated spectrometer geometries with…
We introduce Doppler time-of-flight (D-ToF) rendering, an extension of ToF rendering for dynamic scenes, with applications in simulating D-ToF cameras. D-ToF cameras use high-frequency modulation of illumination and exposure, and measure…
In this work we attempt to establish the best time resolution attainable with a scintillation counter consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode. The measured time resolution is inversely…
The detection of 200-1000 MeV neutrons requires large amounts, $\sim$100 cm, of detector material because of the long nuclear interaction length of these particles. In the example of the NeuLAND neutron time-of-flight detector at FAIR, this…
A method for mathematical treatment is considered for experimental data from pulsed time-of-flight spectrometers, whose response to measurement-initiating pulses is represented by their convolution with the pulse response of the system. The…
To meet the stringent time calibration requirements for the Belle II experiment upgrade, particularly for its large-size KL and Muon Detector comprising tens of thousands of scintillator channels with time resolutions better than 100 ps, we…
A system based on commercially available items, such as a laser diode, emitting in the visible range $\sim 400$ nm,and multimode fiber patches, fused fiber splitters and optical switches may be assembled,for time calibration of…
A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench…
The approximate nature of the adaptive-optics time constant measurements with MASS is examined. The calibration coefficient C derived from numerical simulations of polychromatic scintillation shows dependence on the height of the turbulence…
The Time-of-Flight (ToF) technique coupled with semiconductor-like detectors, as silicon carbide and diamond, is one of the most promising diagnostic methods for high-energy, high repetition rate, laser-accelerated ions allowing a full…
The Time-of-Flight (TOF) system of the AMS detector gives the fast trigger to the read out electronics and measures velocity, direction and charge of the crossing particles. The first version of the detector (called AMS-01) has flown in…
Recent detector concepts at future linear or circular $e^- e^+$ colliders emphasize the benefits of time-of-flight measurements for particle identification of long-lived charged hadrons. That method relies on a precise estimation of the…
Multi-gap Resistive Plate Chamber(MRPC) is a widely used timing detector with a typical time resolution of about 60 ps. This makes MRPC an optimal choice for the time of flight(ToF) system in many large physics experiments. The prior work…
A method is proposed for assessing the temporal resolution of Structured Illumination Microscopy (SIM), by tracking the amplitude of different spatial frequency components over time, and comparing them to a temporally-oscillating…
The Time-of-Flight (TOF) system of the AMS detector gives the fast trigger to the read out electronics and measures velocity, direction and charge of the crossing particles. The first version of the detector (called AMS-01) has flown in…
A new Digital Pulse Processing (DPP) system, based on domino ring sampler version 4 (DRS4), with good time resolution for the LaBr3 detectors has been developed and different digital timing analysis methods for processing the detector raw…