English
Related papers

Related papers: Performance study of a Time of Flight Method used …

200 papers

The barrel time-of-flight detector for the PANDA experiment at FAIR is foreseen as a Scintillator Tile (SciTil) Hodoscope based on several thousand small plastic scintillator tiles read-out with directly attached Silicon Photomultipliers…

Instrumentation and Detectors · Physics 2019-08-14 L. Gruber , S. E. Brunner , J. Marton , H. Orth , K. Suzuki

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

Accurate Time-of-Flight (TOF) measurement with sub-100 picosecond resolution is a critical requirement for particle identification in future high-energy physics experiments, such as the Belle II $K_{L}$ and Muon (KLM) detector upgrade.…

Instrumentation and Detectors · Physics 2026-05-14 Ziyi Yang , Xiyang Wang , Shiming Zou , Ting Wang , Kairui Huang , Wanyi Zhuang , Yicheng Pu , Xiaolong Wang

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Instrumentation and Detectors · Physics 2016-04-19 J. W. Zhao , B. H. Sun , I. Tanihata , S. Terashima , L. H. Zhu , A. Enomoto , D. Nagae , T. Nishimura , S. Omika , A. Ozawa , Y. Takeuchi , T. Yamaguchi

A novel method of hit time and hit position reconstruction in scintillator detectors is described. The method is based on comparison of detector signals with results stored in a library of synchronized model signals registered for a set of…

Balloon- and space-borne cosmic-ray experiments employ plastic scintillators read out by silicon photomultipliers (SiPMs) to achieve picosecond-level time resolutions for triggering and particle identification. The performance of these…

Instrumentation and Detectors · Physics 2025-11-14 José Reyes Castillo , Saúl Aguilar Salazar , Diego Mauricio Gomez Coral

A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $\sigma_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with…

Instrumentation and Detectors · Physics 2016-05-23 P. W. Cattaneo , M. De Gerone , F. Gatti , M. Nishimura , W. Ootani , M. Rossella , S. Shirabe , Y. Uchiyama

Time-of-flight (ToF) measurements is a possible alternative to anti-scatter grids in computed tomography (CT). Simulations have shown a possible 75% reduction in the detrimental scattering contribution with a 100 ps FWHM timing resolution.…

We have tested a prototype time-of-flight system based on bulk scintillator block of dimensions $2.5 \times 2.5 \times 200$ cm. Using a calibration scheme similar to the one used in actual collider experiments, we have achieved a resolution…

High Energy Physics - Experiment · Physics 2007-05-23 E. Chen , M. Saulnier , W. Sun , H. Yamamoto

A new high-granular compact time-of-flight neutron detector for the identification and energy measurement of neutrons produced in nucleus-nucleus interactions at the BM@N experiment, Dubna, Russia, at energies up to 4 AGeV is under…

Instrumentation and Detectors · Physics 2024-08-19 N. Karpushkin , D. Finogeev , F. Guber , D. Lyapin , A. Makhnev , S. Morozov , D. Serebryakov

Using scintillator tile technology several square meters of plastic scintillator are read out by only two photomultiplier with a time precision of about 1.5 nsec. Two examples are discussed to build a detector based on this technology to…

Instrumentation and Detectors · Physics 2016-09-08 J. Baehr , H. -J. Grabosch , V. Kantserov , H. Leich , R. Leiste , R. Nahnhauer

The T2K ND280 upgrade aims to reduce the systematic uncertainty of the CP-violating phase, $\delta_{CP}$, to reject non-CP violation hypothesis at $3\sigma$ confidence level. A crucial component of the ND280 upgrade, alongside the Super…

The barrel time-of-flight (TOF) detector for the PANDA experiment at FAIR in Darmstadt is planned as a scintillator tile hodoscope (SciTil) using 8000 small scintillator tiles. It will provide fast event timing for a software trigger in the…

Instrumentation and Detectors · Physics 2015-06-18 S. E. Brunner , L. Gruber , J. Marton , H. Orth , K. Suzuki

We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon…

A time-of-flight system with a plastic scintillator coupled to photomultipliers is developed for the external target facility (ETF). This system can satisfy the requirement of an ultrahigh vacuum ($\sim 10^{-9}$ mbar), a high counting rate…

Instrumentation and Detectors · Physics 2013-05-23 Zhang Xueheng , Yu Yuhong , Sun Zhiyu , Mao Ruishi , Wang Shitao , Zhou Yong , Yan Duo , Liu Longxiang

A time-of-flight device was developed to characterize wavelength distribution and uniformity of a cold neutron beam. This device is very compact -- the distance of flight is $60$ cm -- but achieves very high resolution -- the intrinsic…

Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $\times$ 50 $\times$…

This paper describes the use of the time-of-flight (TOF) technique as a particle identification method for the HERMES experiment. The time-of-flight is measured by two 1x4 m^2 scintillation hodoscopes that initially were designed for the…

High Energy Physics - Experiment · Physics 2009-11-10 HERMES Collaboration , A. Airapetian , N. Akopov , M. Amarian , H. Avakian , A. Avetissian , E. Avetisyan , B. W. Filippone , R. Kaiser , H. Zohrabian

In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners…

The potential of time-of-flight recoil detection in transmission geometry using pulsed keV ion beams for sensitive multi-element profiling of thin membranes and quasi-2D systems is assessed. While the time-of-flight approach allows for…

Applied Physics · Physics 2022-03-18 R. Holeňák , S. Lohmann , D. Primetzhofer
‹ Prev 1 2 3 10 Next ›