Related papers: Using a 3D printer for 2D beam profile measurement…
Medical synchrotrons are often used for testing instrumentation in high-energy physics or non-clinical research in medical physics. In many applications of medical synchrotrons, such as microdosimetry and ion imaging, precise knowledge of…
The paper reports on a high precision equipment designed to modify over 3-dimensions (3D) by means of high-energy gold ions the local properties of thin and thick films. A target-moving system aimed at creating patterns across the volume is…
The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to…
An instrument has been developed for precision controlled exposures of electronic devices and material samples in particle beams. The instrument provides simultaneously a real time record of the profile of the beam and the fluence received.…
This study investigates the response of Timepix3 semiconductor pixel detectors in proton beams of varying intensities, with a focus on FLASH proton therapy. Using the Timepix3 ASIC chip, we measured the spatial and spectral characteristics…
Treatment planning systems at proton-therapy centres generally use X-ray computed tomography (CT) as primary imaging technique to infer the proton treatment doses to tumour and healthy tissues. However, proton stopping powers in the body,…
This paper presents the results of the proton irradiation of silicon photomulipliers (SiPMs) by mono-energetic 170 MeV protons with fluence up to 4.6$\times$10$^{9}$ particles/cm$^2$. In our work, three types of silicon photodetectors from…
A prototype plastic scintillating fibre based beam profile monitor was tested at the Heidelberg Ion Therapy Centre / \textit{Heidelberg Ionenstrahl Therapiezentrum} (HIT) in 2016 to determine its beam property reconstruction performance and…
Reducing scan times, radiation dose, and enhancing image quality for lower-performance scanners, are critical in low-dose PET imaging. Deep learning techniques have been investigated for PET image denoising. However, existing models have…
This work reports on the performance of a novel neutron-sensitive scintillating detector fabricated using Fused-Deposition Modelling (FDM) additive manufacturing. FDM is a cost-effective 3D-printing method employing flexible plastic…
In order to fully exploit the ballistic potential of particle therapy, we propose an online range monitoring concept based on high-resolution Time-Of-Flight (TOF)-resolved Prompt Gamma (PG) detection in a single proton counting regime. In a…
We demonstrate that powder diffraction data can be collected from sub-micron crystals of a mbrane protein with nearly two orders of magnitude more atoms than the molecules commonly used for powder diffraction. The crystals of photosystem-1…
A new procedure aiming at folding a powder diffraction 2-D into a 1-D scan is presented. The technique consists of three steps: tracking the beam centre by means of a Simulated Annealing (SA) of the diffraction rings along the same axis,…
Particle beams focused to micrometer-sized spots play a crucial role in forefront research using low-energy positrons. Their expedient and wide application, however, requires highly-resolved, fast beam diagnostics. We have developed two…
Liquid scintillating phantoms have been proposed as a means to perform real-time 3D dosimetry for proton therapy treatment plan verification. We have studied what effect radiation damage to the scintillator will have upon this application.…
A number of particle physics experiments are being proposed as part of the Department of Energy HEP Intensity Frontier. Many of these experiments will utilize megawatt level proton beams onto targets to form secondary beams of muons, kaons…
We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in…
We have designed and tested an automated simple setup for quickly measuring the profile and spot size of a Gaussian laser beam using three cost-affordable light sensors. Two profiling techniques were implemented: imaging for the CMOS 2D…
We present the design and initial prototype results of a pixellized proton beam profile monitor for the COMET experiment at J-PARC. The goal of COMET is to look for charged lepton flavor violation by direct muon to electron conversion at a…
Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the…