The steep dose gradients obtained with pencil beam scanning allow for precise tumor targeting at the cost of high sensitivity to uncertainties. Robust optimization is commonly applied to mitigate uncertainties in density and patient setup,…
The interplay between the beam delivery time structure and the patient motion makes 4D dose calculation (4DDC) important when treating moving tumors with intensity modulated proton therapy. 4DDC based on phase sorting of a 4DCT suffers from…
Purpose: The presence of respiratory motion during radiation treatment leads to degradation of the expected dose distribution, both for target coverage and healthy-tissue sparing, particularly for techniques like pencil-beam scanning proton…
Purpose: Pencil beam scanning proton therapy is sensitive to respiratory motion, leading to potential dose inhomogeneities due to interplay effects. We developed and validated a predictive framework to assess interplay and motion robustness…
Purpose: To validate the accuracy of 4D Monte Carlo (4DMC) simulations to calculate dose deliveries to a deforming anatomy in the presence of realistic respiratory motion traces. A previously developed deformable lung phantom comprising an…
We present a method to include robustness into a multi-criteria optimization (MCO) framework for intensity-modulated proton therapy (IMPT). The approach allows one to simultaneously explore the trade-off between different objectives as well…
Robust treatment planning algorithms for Intensity Modulated Proton Therapy (IMPT) and Intensity Modulated Radiation Therapy (IMRT) allow for uncertainty reduction in the delivered dose distributions through explicit inclusion of error…
Background: Dose calculation and optimization algorithms in proton therapy treatment planning often have high computational requirements regarding time and memory. This can hinder the implementation of efficient workflows in clinics and…
Purpose: To demonstrate the feasibility of fast Monte Carlo (MC) based inverse biological planning for the treatment of head and neck tumors in spot-scanning proton therapy. Methods: Recently, a fast and accurate Graphics Processor Unit…
Robust optimization is a commonly employed method to mitigate uncertainties in the planning of intensity-modulated proton therapy (IMPT). In certain contexts, the large number of uncertainty scenarios makes the robust problem impractically…
When treating moving tumors, the precise delivery of proton therapy by pencil beam scanning (PBS) is challenged by the interplay effect. Although several 4D-optimization methods have been proposed, what is the most beneficial motion…
Accurate proton dose calculation using Monte Carlo (MC) is computationally demanding in workflows like robust optimisation, adaptive replanning, and probabilistic inference, which require repeated evaluations. To address this, we develop a…
Carbon-ion radiotherapy provides high dose conformity for lung cancer, but its benefit is limited by two sources of uncertainties: interplay between scanned beam delivery and tumor motion, and dose modulation from heterogeneous lung tissue.…
Purpose: The importance of robust proton treatment planning to mitigate the impact of uncertainty is well understood. However, its computational cost grows with the number of uncertainty scenarios, prolonging the treatment planning process.…
Background and purpose: IMPT faces challenges in lung cancer treatment, like maintaining plan robustness for moving tumors against setup, range errors, and interplay effects. Proton Arc Therapy (PAT) is an alternative to maintain target…
Treatment planning uncertainties are typically managed using margin-based or robust optimization. Margin-based methods expand the clinical target volume (CTV) to a planning target volume, generally unsuited for proton therapy. Robust…
Interfractional geometric uncertainties can lead to deviations of the actual delivered dose from the prescribed dose distribution. To better handle these uncertainties during treatment, the authors propose a dynamic framework for robust…
Intensity modulated proton therapy (IMPT) provides highly conformal dose distributions through the application of multiple, angularly spaced fields, each applying an ad-hoc pattern of spatially varying particle fluences. In particular,…
The high precision and conformity of intensity-modulated particle therapy (IMPT) comes at the cost of susceptibility to treatment uncertainties in particle range and patient set-up. Dose uncertainty quantification and mitigation, which is…
Purpose: To improve target coverage and reduce the dose in the surrounding organs-at-risks (OARs), we developed an image-guided treatment method based on a precomputed library of treatment plans controlled and delivered in real-time.…