Treatment planning uncertainties are typically managed using margin-based or robust optimization. Margin-based methods expand the clinical target volume (CTV) to a planning target volume, generally unsuited for proton therapy. Robust optimization considers worst-case scenarios, but its quality depends on the uncertainty scenario set: excluding extremes reduces robustness, while too many make plans overly conservative. Probabilistic optimization overcomes these limits by modeling a continuous scenario distribution. We propose a novel probabilistic optimization approach that steers plans toward individualized probability levels to control CTV and organs-at-risk (OARs) under- and overdosage. Voxel-wise dose percentiles (dd) are estimated by expected value (EE) and standard deviation (SD) as E[d]±δSD[d]E[d] \pm \delta \cdot SD[d], where δ\delta is iteratively tuned to match the target percentile given Gaussian-distributed setup (3 mm) and range (3%) uncertainties. The method involves an inner optimization of E[d]±δSD[d]E[d] \pm \delta \cdot SD[d] for fixed δ\delta, and an outer loop updating δ\delta. Polynomial Chaos Expansion (PCE) provides accurate and efficient dose estimates during optimization. We validated the method on a spherical CTV abutted by an OAR in different directions and a horseshoe-shaped CTV surrounding a cylindrical spine. For spherical cases with similar CTV coverage, P(D2%>30Gy)P(D_{2\%} > 30 Gy) dropped by 10-15%; for matched OAR dose, P(D98%>57Gy)P(D_{98\%} > 57 Gy) increased by 67.5-71%. In spinal plans, P(D98%>57Gy)P(D_{98\%} > 57 Gy) increased by 10-15% while P(D2%>30Gy)P(D_{2\%} > 30 Gy) dropped 24-28%. Probabilistic and robust optimization times were comparable for spherical (hours) but longer for spinal cases (7.5 - 11.5 h vs. 9 - 20 min). Compared to discrete scenario-based optimization, the probabilistic method offered better OAR sparing or target coverage depending on the set priorities.

Keywords

Cite

@article{arxiv.2507.01763,
  title  = {Probabilistic Proton Treatment Planning: a novel approach for optimizing underdosage and overdosage probabilities of target and organ structures},
  author = {Jelte R. de Jong and Sebastiaan Breedveld and Steven J. M. Habraken and Mischa S. Hoogeman and Danny Lathouwers and Zoltán Perkó},
  journal= {arXiv preprint arXiv:2507.01763},
  year   = {2025}
}

Comments

47 pages, 28 figures