English
Related papers

Related papers: Improved low-count quantitative PET reconstruction…

200 papers

In this work, we present a novel self-supervised method for Low Dose Computed Tomography (LDCT) reconstruction. Reducing the radiation dose to patients during a CT scan is a crucial challenge since the quality of the reconstruction highly…

Image and Video Processing · Electrical Eng. & Systems 2023-12-21 Hang Xu , Alessandro Perelli

The goal of this paper is to present a non-iterative and more importantly an extremely fast algorithm to reconstruct images from compressively sensed (CS) random measurements. To this end, we propose a novel convolutional neural network…

Computer Vision and Pattern Recognition · Computer Science 2016-03-09 Kuldeep Kulkarni , Suhas Lohit , Pavan Turaga , Ronan Kerviche , Amit Ashok

The reconstruction of dynamic positron emission tomography (PET) images from noisy projection data is a significant but challenging problem. In this paper, we introduce an unsupervised learning approach, Non-negative Implicit Neural…

Computer Vision and Pattern Recognition · Computer Science 2025-06-25 Chaozhi Zhang , Wenxiang Ding , Roy Y. He , Xiaoqun Zhang , Qiaoqiao Ding

Image denoising techniques are essential to reducing noise levels and enhancing diagnosis reliability in low-dose computed tomography (CT). Machine learning based denoising methods have shown great potential in removing the complex and…

Computer Vision and Pattern Recognition · Computer Science 2017-08-29 Dufan Wu , Kyungsang Kim , Georges El Fakhri , Quanzheng Li

Single image super-resolution (SISR), as a traditional ill-conditioned inverse problem, has been greatly revitalized by the recent development of convolutional neural networks (CNN). These CNN-based methods generally map a low-resolution…

Image and Video Processing · Electrical Eng. & Systems 2024-10-30 Yuqing Liu , Shiqi Wang , Jian Zhang , Shanshe Wang , Siwei Ma , Wen Gao

Model-Based Iterative Reconstruction (MBIR) is important because direct methods, such as Filtered Back-Projection (FBP) can introduce significant noise and artifacts in sparse-angle tomography, especially for time-evolving samples. Although…

Mathematical Software · Computer Science 2026-03-31 Dinesh Kumar , Jeffrey Donatelli

Dose reduction in computed tomography (CT) is essential for decreasing radiation risk in clinical applications. Iterative reconstruction is one of the most promising ways to compensate for the increased noise due to reduction of photon…

Image and Video Processing · Electrical Eng. & Systems 2021-03-24 Zhuonan He , Yikun Zhang , Yu Guan , Shanzhou Niu , Yi Zhang , Yang Chen , Qiegen Liu

In this paper, we present a deep learning algorithm to rapidly obtain high quality CT reconstructions for AM parts. In particular, we propose to use CAD models of the parts that are to be manufactured, introduce typical defects and simulate…

Computer Vision and Pattern Recognition · Computer Science 2019-09-04 Amirkoushyar Ziabari , Michael Kirka , Vincent Paquit , Philip Bingham , Singanallur Venkatakrishnan

Lighter and faster image restoration (IR) models are crucial for the deployment on resource-limited devices. Binary neural network (BNN), one of the most promising model compression methods, can dramatically reduce the computations and…

Computer Vision and Pattern Recognition · Computer Science 2023-02-17 Bin Xia , Yulun Zhang , Yitong Wang , Yapeng Tian , Wenming Yang , Radu Timofte , Luc Van Gool

Cone beam computed tomography (CBCT) is an emerging medical imaging technique to visualize the internal anatomical structures of patients. During a CBCT scan, several projection images of different angles or views are collectively utilized…

Image and Video Processing · Electrical Eng. & Systems 2024-01-18 Heejun Shin , Taehee Kim , Jongho Lee , Se Young Chun , Seungryung Cho , Dongmyung Shin

Model-Based Image Reconstruction (MBIR) methods significantly enhance the quality of computed tomographic (CT) reconstructions relative to analytical techniques, but are limited by high computational cost. In this paper, we propose a…

Image and Video Processing · Electrical Eng. & Systems 2019-11-22 Venkatesh Sridhar , Xiao Wang , Gregery T. Buzzard , Charles A. Bouman

In this study we evaluated the task-based image quality of a low contrast clinical task for the abdomen protocol (e.g., pancreatic tumour) of three different CT vendors, exploiting three model-based iterative reconstruction (MBIR) levels.…

Medical Physics · Physics 2023-01-23 G. Muti , S. Riga , L. Berta , D. Curto , C. De Mattia , M. Felisi , F. Rizzetto , A. Torresin , A. Vanzulli , P. E. Colombo

Low-dose computed tomography (CT) allows the reduction of radiation risk in clinical applications at the expense of image quality, which deteriorates the diagnosis accuracy of radiologists. In this work, we present a High-Quality Imaging…

Image and Video Processing · Electrical Eng. & Systems 2021-04-02 Jingfeng Lu , Shuo Wang , Ping Li , Dong Ye

In this paper, we introduced a novel deep learning-based reconstruction technique for low-dose CT imaging using 3 dimensional convolutions to include the sagittal information unlike the existing 2 dimensional networks which exploits…

Computer Vision and Pattern Recognition · Computer Science 2022-04-19 Doga Gunduzalp , Batuhan Cengiz , Mehmet Ozan Unal , Isa Yildirim

Implicit neural representations (INRs) have demonstrated strong capabilities in various medical imaging tasks, such as denoising, registration, and segmentation, by representing images as continuous functions, allowing complex details to be…

Image and Video Processing · Electrical Eng. & Systems 2025-03-31 Younès Moussaoui , Diana Mateus , Nasrin Taheri , Saïd Moussaoui , Thomas Carlier , Simon Stute

One-sided ultrasonic non-destructive evaluation (UNDE) is extensively used to characterize structures that need to be inspected and maintained from defects and flaws that could affect the performance of power plants, such as nuclear power…

Image and Video Processing · Electrical Eng. & Systems 2018-08-13 Hani Almansouri , Singanallur Venkatakrishnan , Charles Bouman , Hector Santos-Villalobos

Utilizing a low-dose CT approach significantly reduces the radiation exposure for patients, yet it introduces challenges, such as increased noise and artifacts in the resultant images, which can hinder accurate medical diagnostics.…

Image and Video Processing · Electrical Eng. & Systems 2024-04-03 Helena Shawn , Thompson Chyrikov , Jacob Lanet , Lam-chi Chen , Jim Zhao , Christina Chajo

Despite remarkable progress on visual recognition tasks, deep neural-nets still struggle to generalize well when training data is scarce or highly imbalanced, rendering them extremely vulnerable to real-world examples. In this paper, we…

Computer Vision and Pattern Recognition · Computer Science 2022-06-22 Shiran Zada , Itay Benou , Michal Irani

Magnetic resonance imaging (MRI) is increasingly utilized for image-guided radiotherapy due to its outstanding soft-tissue contrast and lack of ionizing radiation. However, geometric distortions caused by gradient nonlinearity (GNL) limit…

The resurgence of deep neural networks has created an alternative pathway for low-dose computed tomography denoising by learning a nonlinear transformation function between low-dose CT (LDCT) and normal-dose CT (NDCT) image pairs. However,…

Image and Video Processing · Electrical Eng. & Systems 2022-11-04 Sutanu Bera , Prabir Kumar Biswas