Related papers: SiPM-based neutron Anger camera with auto-calibrat…

200 papers

We characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved…

Instrumentation and Detectors · Physics 2024-01-31 J. Balajthy , P. Marleau , M. Sweany

Scintillators capable of detecting both neutrons and gamma-rays have generated considerable interest. In particular, the use of such scintillators with silicon photomultipliers (SiPMs) enables low-power and compact-geometry applications.…

Instrumentation and Detectors · Physics 2018-08-29 Felix Liang , Hartmut Brands , Les Hoy , Jeff Preston , Jason Smith

The design and performance of a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described. Measurements with…

The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved…

The Group for the development of neutron and gamma detectors in the Central Institute of Engineering, Electronics and Analytics (ZEA-2) at Forschungszentrum Juelich (FZJ) has developed, in collaboration with European institutes, an Anger…

Instrumentation and Detectors · Physics 2013-04-25 R. Fabbri , U. Clemens , R. Engels , G. Kemmerling , S. van Waasen , Forschungszentrum Juelich

The detection of 200-1000 MeV neutrons requires large amounts, $\sim$100 cm, of detector material because of the long nuclear interaction length of these particles. In the example of the NeuLAND neutron time-of-flight detector at FAIR, this…

In the work presented here we built and evaluated a single-channel neutron detection unit consisting of a ZnS:$^6$LiF scintillator with embedded WLS fibers readout by a SiPM. The unit has a sensitive volume of 2.4 x 2.8 x 50 mm$^3$; 12 WLS…

Instrumentation and Detectors · Physics 2015-12-09 A. Stoykov , J. -B. Mosset , U. Greuter , M. Hildebrandt , N. Schlumpf

The Group for the development of neutron and gamma detectors in the Central Institute of Engineering, Electronics and Analytics (ZEA-2) at Forschungszentrum J\"ulich (FZJ) is developing a fast Anger Camera prototype for improving the…

Instrumentation and Detectors · Physics 2013-07-17 R. Fabbri , R. Engels

We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm…

The NeuLAND (New Large-Area Neutron Detector) plastic-scintillator-based time-of-flight detector for 0.1-1.6 GeV neutrons is currently under construction at the Facility for Antiproton and Ion Research (FAIR), Darmstadt, Germany. In its…

Instrumentation and Detectors · Physics 2023-01-11 Thomas Hensel , David Weinberger , Daniel Bemmerer , Konstanze Boretzky , Igor Gašparić , Daniel Stach , Andreas Wagner , Kai Zuber

In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and $\gamma$-ray Compton scatterer of the novel dual \g-ray and neutron imaging system GN-Vision, which aims at…

This paper presents the model-based design and evaluation of an instrument that estimates incident neutron direction using the kinematics of neutron scattering by hydrogen-1 nuclei in an organic scintillator. The instrument design uses a…

Instrumentation and Detectors · Physics 2017-12-13 Kyle Weinfurther , John Mattingly , Erik Brubaker , John Steele

Silicon photomultipliers (SiPMs) are a good alternative to photomultiplier tubes (PMTs) because their gain and quantum efficiency are comparable to PMTs. However, the largest single-chip SiPM is still less than 1~cm$^2$. In order to use…

Instrumentation and Detectors · Physics 2017-11-17 Felix Liang , Hartmut Brands , Les Hoy , Jeff Preston , Jason Smith

Compact gamma cameras with a square-shaped monolithic scintillator crystal and an array of silicon photomultipliers (SiPMs) are actively being developed for applications in areas such as small animal imaging, cancer diagnostics and…

Medical Physics · Physics 2017-04-26 A. Morozov , F. Alves , J. Marcos , R. Martins , L. Pereira , V. Solovov , V. Chepel

The characterization of a liquid scintillator incorporating an aqueous solution of enriched lithium chloride to produce a scintillator with 0.40% Li-6 is presented, including the performance of the scintillator in terms of its optical…

Instrumentation and Detectors · Physics 2013-04-23 C. D. Bass , E. J. Beise , H. Breuer , C. R. Heimbach , T. Langford , J. S. Nico

We present a novel geometry of scintillator tiles developed for fiberless coupling to silicon photomultipliers (SiPMs) for applications in highly granular calorimeters. A high degree of uniformity of the tile response over the full active…

Instrumentation and Detectors · Physics 2010-12-13 Frank Simon , Christian Soldner

A $^{6}$Li glass based scintillation detector developed for the TRIUMF neutron electric dipole moment experiment was characterized using the ultra-cold neutron source at the Paul Scherrer Institute (PSI). The data acquisition system for…

Instrumentation and Detectors · Physics 2017-02-01 Blair Jamieson , Lori A Rebenitsch , Sean Hansen-Romu , Bernhard Lauss , Thomas Lindner , Jeffery W Martin , Edgard Pierre

In order to develop a high spatial resolution (micron level) thermal neutron detector, a detector assembly composed of cerium doped lithium glass microfibers, each with a diameter of 1\,$\mu$m, is proposed, where the neutron absorption…

Instrumentation and Detectors · Physics 2016-06-14 Song Yushou , Joseph Conner , Xiaodong Zhang , Jason P. Hayward

Precision calorimetry using highly granular sampling calorimeters is being developed based on the particle flow concept within the CALICE collaboration. One design option of a hadron calorimeter is based on silicon photomultipliers (SiPMs)…

Silicon PhotoMultipliers (SiPM) are an excellent choice for the scintillator light readout at hadron calorimeters due to their insensitivity to magnetic fields, low operating voltages, low cost, compactness and mechanical endurance. They…

Instrumentation and Detectors · Physics 2020-01-29 V. Mikhaylov , F. Guber , A. Ivashkin , A. Kugler , V. Kushpil , S. Morozov , O. Svoboda , P. Tlusty