Related papers: SiPM-based neutron Anger camera with auto-calibrat…
This paper presents a newly developed plastic scintillator produced in collaboration with Turkiye Energy, Nuclear and Mineral Research Agency (TENMAK). The scintillator is manufactured using thermal polymerization of commercially available…
This study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to…
The photon detection system of the first far detector (FD1-HD) of the DUNE experiment will detect scintillation photons produced by particle interactions in a kiloton-scale liquid Argon time projection chamber. The photon detectors of…
The response of the liquid scintillator array Nordball to neutrons in the energy range 1.5 < T_n < 10 MeV has been measured by time of flight using a 252Cf fission source. Fission fragments were detected by means of a thin-film plastic…
Radon is the main background source of dark matter and neutrino experiments. Radon concentration ($\rm mBq/m^3$) measurement by liquid scintillation detector is a highly sensitive method at low temperatures using silicon photomultipliers…
The principle of operation, design, registration system and main characteristics of a fast neutrons spectrometer are described. The spectrometer is intended for direct measurements of ultra low fluxes of fast neutrons. It is sensitive to…
To study the dependence of the equation of state of high density nuclear matter on the term characterizing the isospin (proton-neutron) asymmetry of nuclear matter, it is necessary to measure azimuthal flow of neutrons as well as azimuthal…
We present a digital signal processing system based on a photon counting approach which we developed for a thermal neutron detector consisting of ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs. Three digital filters…
We have developed a compact Compton gamma-ray imager with a large field of view and a low channel-count that is capable of quickly localizing gamma-ray sources in the few hundred keV - several MeV range. The two detector planes (scatter and…
The temperature of a nonneutral plasma confined in a Penning-Malmberg trap can be determined by slowly lowering one side of the trap's electrostatic axial confinement barrier; the temperature is inferred from the rate at which particles…
Unlike most commercially available silicon photomultipliers (SiPMs), EQR20 SiPMs produced by the Novel Device Laboratory (NDL) avoid using individual resistors to quench the avalanche multiplication of the microcells. Instead, bulk…
The Italian Institute of Nuclear Physics (INFN) is involved in the development of a demonstrator for a SiPM-based camera for the Cherenkov Telescope Array (CTA) experiment, with a pixel size of 6$\times$6 mm$^2$. The camera houses about two…
We present a 'digital SiPM' photo-detection chip combining single photon sensitive avalanche photo diodes and CMOS readout electronics on a single die. The chip has a size of $8046\times9032\,\mu m^2$ with $72.5\%$ of photo sensitive area.…
There is growing interest in high-energy astrophysics community for the development of sensitive instruments in the hard X-ray energy extending to few hundred keV. This requires position sensitive detector modules with high efficiency in…
The demand for new thermal neutron detectors as an alternative to 3He tubes in research, industrial, safety and homeland security applications, is growing. These needs have triggered research and development activities about new generations…
The efficiency and energy resolution of the MAST neutron camera detectors, based on liquid scintillator of the EJ-301 type, is lower than cylindrical detector of similar size. An experimental investigation has identified light attenuation…
The detector of TRopIcal DEep-sea Neutrino Telescope (TRIDENT) will use large-area silicon photomultiplier (SiPM) arrays combined with photomultiplier tubes to boost photon detection efficiency and pointing capability. An…
Particle detectors based on liquid argon are now recognised as an attractive technology for dark matter direct detection and coherent elastic neutrino-nucleus scattering measurement. A program using a dual-phase liquid argon detector with a…
Silicon Photomultipliers (SiPMs) are attractive candidates for light detectors for next generation liquid xenon double-beta decay experiments, like nEXO. In this paper we discuss the requirements that the SiPMs must satisfy in order to be…
Silicon photomultipliers present saturation effects as they have a limited number of pixels and work in Geiger mode. Their response to light pulses in the nonlinear region is very complex for two reasons: pixel recharging after an avalanche…