Related papers: Cryogenic light detectors with enhanced performanc…
CUORE is the first ton-scale experiment based on the bolometric technique to search for neutrinoless double-beta decay. Its core is made of 988 $\mathrm{TeO_{2}}$ crystals cooled down to $10~\mathrm{mK}$. The temperature must be as stable…
The Cryogenic Underground Observatory for Rare Events (CUORE) experiment at Gran Sasso National Laboratory of INFN searches for neutrinoless double beta decay using TeO2 crystals as cryogenic bolometers. The sensitivity of the measurement…
We are developing multi-chroic antenna-coupled TES detectors for CMB polarimetry. Multi-chroic detectors increase the mapping speed per focal plane area and provide greater discrimination of polarized galactic foregrounds with no increase…
In recent times, the sensitivity of low-mass direct dark matter searches has been limited by unknown low energy backgrounds close to the energy threshold of the experiments known as the low energy excess (LEE). The CRESST experiment…
In the field of Double Beta Decay (DBD) searches, the use of high resolution detectors in which background can be actively discriminated is very appealing. Scintillating bolometers containing a Double Beta Decay emitter can largely fulfill…
In this work, a first cryogenic characterization of a scintillating LiAlO$_{2}$ single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three…
The symmetric $e^+e^-$ collider CESR is undergoing a series of upgrades allowing for luminosities in excess of $2\times 10^{33}$cm$^{-2}$s$^{-1}$. The most important goals of the upgrade are precision measurement of standard model…
Scintillation properties of pure CsI crystals used in the shower calorimeter being built for precise determination of the pi+ -> pi0 e+ nu decay rate are reported. Seventy-four individual crystals, polished and wrapped in Teflon foil, were…
The Simons Observatory aims to field 70,000 Transition-Edge Sensor (TES) bolometers to measure the Cosmic Microwave Background. With so many detectors, rapid but accurate validation of their properties prior to their integration into…
In the case of underground experiments for neutrino physics or rare event searches, the background caused by cosmic muons contributes significantly and therefore must be identified and rejected. We proposed and optimized a new detector…
The current generation of cryogenic solid state detectors used in direct dark matter and CE\textnu NS searches typically reach energy thresholds of $\mathcal{O}$(10)$\,$eV for nuclear recoils. For a reliable calibration in this energy…
The cryogenic dark matter experiment CRESST-II aims at the direct detection of WIMPs via elastic scattering off nuclei in scintillating CaWO$_4$ crystals. We present a new, highly improved, detector design installed in the current run of…
Experiments searching for rare events, such as neutrinoless double beta decay and interactions of dark matter candidates, require extremely low levels of background. When these experiments are performed using macro-bolometers, radioactive…
Solid state detectors and cryogenic detectors are widely employed in rare event searches, such as direct Dark Matter detection or Coherent Neutrino Nucleus Scattering experiments. The excellent sensitivity and, consequently, their low…
The development of cryogenic calorimeters was originally motivated by the fact that very low energy thresholds and excellent energy resolutions can be achieved by these devices. Cryogenic devices are widely used in double beta decay…
On-chip photodetectors are essential components in optical communications as they convert light into an electrical signal. Photobolometers are type of photodetector that functions through a resistance change caused by electronic temperature…
In order to develop a high spatial resolution (micron level) thermal neutron detector, a detector assembly composed of cerium doped lithium glass microfibers, each with a diameter of 1\,$\mu$m, is proposed, where the neutron absorption…
CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background…
We present the current status of CRESST(Cryogenic Rare Event Search using Superconducting Thermometers) project and new results concerning the development of new detectors based on the simultaneous measurement of phonons and scintillation…
We report on efforts to improve the speed of low-G far-infrared transition-edged-sensed bolometers. We use a fabrication process that does not require any dry etch steps to reduce heat capacity on the suspended device and measure a…