Related papers: The GlueX Start Counter Detector
A CubeSat with a prototype scintillating detector with a sensitive volume of GAGG crystal is being developed with a possible launch date of 2025. Its purpose is to characterize the background signals that mimic the neutrino interaction that…
We present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge-sensors…
A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation,…
Providing a background discrimination tool is crucial for enhancing the sensitivity of next-generation experiments searching for neutrinoless double- beta decay. The development of high-sensitivity (< 20 eV RMS) cryogenic light detectors…
Silicon photomultipliers (SiPMs) are a good alternative to photomultiplier tubes (PMTs) because their gain and quantum efficiency are comparable to PMTs. However, the largest single-chip SiPM is still less than 1~cm$^2$. In order to use…
The MuPix7 is a prototype high voltage monolithic active pixel sensor with 103 times 80 um2 pixels thinned to 64 um and incorporating the complete read-out circuitry including a 1.25 Gbit/s differential data link. Using data taken at the…
Electrons are emerging as a strong complement to X-rays for diffraction based studies. In this paper we investigate the performance of a JUNGFRAU detector with 320 um thick silicon sensor at a pulsed electron source. Originally developed…
We report on the design of a serializer ASIC to be used in the ATLAS forward muon detector for trigger data transmission. We discuss the performance of a prototype chip covering power dissipation, latency and stable operating line rate.…
In order to fully reconstruct to the reaction e+e- to e+e- gamma-gamma in the energy region of the phi meson production, new detectors along the DAFNE beam line have to be installed in order to detect the scattered e+e-. The High Energy…
A new electromagnetic calorimeter composed of 1596 lead tungstate (PbWO$_4$) scintillating crystals has been constructed for the GlueX detector in Hall D at Jefferson Lab. The calorimeter is equipped with a light monitoring system that uses…
A GridPix readout for a TPC based on the Timepix3 chip is developed for future applications at a linear collider. The GridPix detector consists of a gaseous drift volume read out by a single Timepix3 chip with an integrated amplification…
A double-layer silicon detector consisting of two 500micron-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1-30 keV with an effective…
We are constructing a Silicon Vertex Tracker detector (VTX) for the PHENIX experiment at RHIC. Our main motivation is to enable measurements of heavy flavor production (charm and beauty) in p+p, p+d and A+A collisions. Such data will…
We have built a gas-phase argon ionization detector to measure small nuclear recoil energies (< 10 keVee). In this paper, we describe the detector response to X-ray and gamma calibration sources, including analysis of pulse shapes, software…
The time resolution for a charged particle detection is reported for a typical scintillating fiber detector instrumented with Rockwell HISTE-IV Visible Light Photon Counters. The resolution measurements are shown to agree with a simple…
A novel composite, scintillating material intended for neutron detection and composed of small (1.5 mm) cubes of KG2-type lithium glass embedded in a matrix of scintillating plastic has been developed in the form of a 2.2 in.-diameter, 3.1…
For the first time, a small dual-phase (liquid/gas) xenon time projection chamber was equipped with a top array of silicon photomultipliers for light and charge readout. Here we describe the instrument in detail, as well as the data…
The High Luminosity LHC (HL-LHC) upgrade requires the planned Inner Tracker (ITk) of the ATLAS detector to tolerate extremely high radiation doses. Specifically, the innermost parts of the pixel system will have to withstand radiation…
A network of 16 Medipix-2 (MPX) silicon pixel devices was installed in the ATLAS detector cavern at CERN. It was designed to measure the composition and spectral characteristics of the radiation field in the ATLAS experiment and its…
For radiography applications using fast neutrons simultaneously with gammas we have developed a detector with 16 stilbene crystals in a 4$\times$4 2D array with a 5~mm pitch and a depth of 25~mm. The crystal array is read out by Silicon…