Related papers: The GlueX Start Counter Detector
A scaler has been fabricated to count the signals from any radiation de- tector. It can count signals of frequency up to 140 kHz. Transistor Transistor Logic (TTL) is used in this scaler. In this article the details of the design,…
The timing performance of the Timepix4 application-specific integrated circuit (ASIC) bump-bonded to a $100\;\mu\textrm{m}$ thick n-on-p silicon sensor is presented. A picosecond pulsed infrared laser was used to generate electron-hole…
Multichip modules (MCM) with 4 single photon counting MPEC 2.3 chips bump bonded to 1.3 cm x 1.3 cm large CdTe and Si semiconductor sensors as well as to single chip pixel detectors have been successfully built and operated. The MPEC 2.3…
The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium…
A new silicon detector has been developed to provide the PHENIX experiment with precise charged particle tracking at forward and backward rapidity. The Forward Silicon Vertex Tracker (FVTX) was installed in PHENIX prior to the 2012 run…
The Microhexcavity Panel ( muHex) is a novel gaseous micropattern particle detector comprised of a dense array of close-packed hexagonal pixels, each operating as an independent detection unit for ionizing radiation. It is a second…
Small-pitch 3D silicon pixel detectors have been investigated as radiation-hard candidates for the innermost layers of the HL-LHC pixel detector upgrades. Prototype 3D sensors with pixel sizes of 50$\times$50 and 25$\times$100 $\mu$m$^{2}$…
A whole class of two-color experiments involves intense, short Terahertz radiation pulses. A fast detector that is sensitive and able to resolve both near-infrared and Terahertz pulses at the same time is highly desirable. Here we present…
The ZEUS Central Tracking Detector utilizes a time difference measurement to provide a fast determination of the z-coordinate of each hit. The z-by-timing measurement is achieved by using a Time-to-Amplitude Converter which has an intrinsic…
Characteristics of a scintillation proportional counter with WLS fiber optics readout is described. The possibility of detection of the proportional scintillation signal produced by the single electron of primary ionization is shown. The…
This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first…
We report on the design, production, and testing of advanced double-sided silicon strip detectors under development at the Max-Planck-Institute as part of the Medium Energy Gamma-ray Astronomy (MEGA) project. The detectors are designed to…
We construct a high sensitivity radon pilot detector using liquid scintillator dissolved radon for the CDEX rare-event searches program. The CDEX-10 project employs a germanium detector array immersed in a massive liquid nitrogen tank.…
A light emitting diode (LED) pulser has been developed that can be used for tests or calibration of timing and amplitude sensitivity of particle physics detectors. A comparative study is performed on the components and pulser output…
Cluster counting dN/dx is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good pion-kaon separation over a broad momentum range is…
Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In…
A front-end readout electronics system has been developed for silicon strip detectors. The system uses an application specific integrated circuit (ASIC) ATHED to realize multi-channel E&T measurement. The slow control of ASIC chips is…
In the context of the studies of the ATLAS High Luminosity LHC programme, radiation tolerant pixel detectors in CMOS technologies are investigated. To evaluate the effects of substrate resistivity on CMOS sensor performance, the H35DEMO…
This paper presents a fast impedance measurement IC for large-scale piezo-resistive sensor array. It features a unified differential time-to-digital demodulation architecture that readout impedance directly through the excitation circuit.…
This work presents the design and preliminary performance of a highly-multiplexed superconducting detector readout. The readout system is implemented on the Xilinx ZCU111 RFSoC Evaluation Board. The current design uses 12% of the DSPs, 60%…