English
Related papers

Related papers: Charge collection properties of irradiated deplete…

200 papers

Charge collection properties of depleted CMOS pixel detector prototypes produced on p-type substrate of 2 k$\Omega$cm initial resistivity (by LFoundry 150 nm process) were studied using Edge-TCT method before and after neutron irradiation.…

In this paper results of Edge-TCT and I-V measurements with passive test structures made in LFoundry 150 nm HV-CMOS process on p-type substrates with different initial resistivities ranging from 0.5 to 3 k$\Omega$cm are presented. Samples…

Investigation of HV-CMOS sensors for use as a tracking detector in the ATLAS experiment at the upgraded LHC (HL-LHC) has recently been an active field of research. A potential candidate for a pixel detector built in Silicon-On-Insulator…

Instrumentation and Detectors · Physics 2017-10-27 B. Hiti , V. Cindro , A. Gorišek , T. Hemperek , T. Kishishita , G. Kramberger , H. Krüger , I. Mandić , M. Mikuž , N. Wermes , M. Zavrtanik

Thin pad detectors made from 75 $\mu$m thick epitaxial silicon on low resistivity substrate were irradiated with reactor neutrons to fluences from 2.5$\times 10^{16}$ n/cm$^2$ to 1$\times 10^{17}$ n/cm$^2$. Edge-TCT measurements showed that…

Instrumentation and Detectors · Physics 2020-12-30 I. Mandić , V. Cindro , A. Gorišek , B. Hiti , G. Kramberger , M. Mikuž , M. Zavrtanik , P. Skomina , S. Hidalgo , G. Pellegrini

In this work, charge collection profiles of non-irradiated and irradiated 150 $\mu$m $p$-type pad diodes were measured using a 5.2 GeV electron beam traversing the diode parallel to the readout electrode. Four diodes were irradiated to 1…

This paper reports on the characterisation with Transient Current Technique measurements of the charge collection and depletion depth of a radiation-hard high-voltage CMOS pixel sensor produced at ams AG. Several substrate resistivities…

This paper contains a compilation of parameters influencing the charge collection process extracted from a comprehensive study of partially depleted Monolithic Active Pixel Sensors with small (<25 um$^2$) collection electrodes fabricated in…

A method is presented which allows to obtain the position-dependent electric field and charge density by fits to velocity profiles from edge-TCT data from silicon strip-detectors. The validity and the limitations of the method are…

Instrumentation and Detectors · Physics 2020-01-08 R. Klanner , G. Kramberger , I. Mandic , M. Mikuz , M. Milovanovic , J. Schwandt

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and…

An extensive sensor testing campaign is presented, dedicated to measuring the charge collection properties of prototype candidates for the Vertex Locator (VELO) detector for the upgraded LHCb experiment. The charge collection is measured…

Low noise CCDs fully-depleted up to 675 micrometers have been identified as a unique tool for Dark Matter searches and low energy neutrino physics. The charge collection efficiency (CCE) for these detectors is a critical parameter for the…

Instrumentation and Detectors · Physics 2021-06-16 Guillermo Fernandez-Moroni , Kevin Andersson , Ana Botti , Juan Estrada , Dario Rodrigues , Javier Tiffenberg

Charge multiplication (CM) in p$^+$n epitaxial silicon pad diodes of 75, 100 and 150 $\upmu$m thickness at high voltages after proton irradiation with 1 MeV neutron equivalent fluences in the order of $10^{16}$ cm$^{-2}$ was studied as an…

Instrumentation and Detectors · Physics 2014-11-21 Jörn Lange , Julian Becker , Eckhart Fretwurst , Robert Klanner , Gunnar Lindström

The collected charge of two pad diodes is measured along the diode width using a 5:2 GeV electron beam at the DESY II beam test facility. The electron beam enters parallel to the readout electrode plane and perpendicular to the edge of the…

Instrumentation and Detectors · Physics 2021-12-16 Mohammadtaghi Hajheidari , Erika Garutti , Joern Schwandt , Aliakbar Ebrahimi

Silicon pixel detectors produced according to the ATLAS Pixel Detector design were tested in a beam at CERN in the framework of the ATLAS collaboration. The detectors used n+/n sensors with oxygenated silicon substrates. The experimental…

High Energy Physics - Experiment · Physics 2007-05-23 T. Lari

Due to the increased commercial availability, wide-bandgap semiconductors and their radiation hardness have recently received increased interest from the particle physics community. 4H-Silicon Carbide (SiC), especially, is an attractive…

Instrumentation and Detectors · Physics 2024-12-11 Andreas Gsponer , Philipp Gaggl , Jürgen Burin , Simon Waid , Thomas Bergauer

Active edge p-on-p silicon pixel detectors with thickness of 100 $\mu$m were fabricated on 150 mm Float zone silicon wafers at VTT. By combining measured results and TCAD simulations, a detailed study of electric field distributions and…

Instrumentation and Detectors · Physics 2016-02-17 T. Peltola , X. Wu , J. Kalliopuska , C. Granja , J. Jakubek , M. Jakubek , J. Härkönen , A. Gädda

The apparatus of the ALICE experiment at CERN will be upgraded in 2017/18 during the second long shutdown of the LHC (LS2). A major motivation for this upgrade is to extend the physics reach for charmed and beauty particles down to low…

During the scheduled high luminosity upgrade of LHC, the world's largest particle physics accelerator at CERN, the position sensitive silicon detectors installed in the vertex and tracking part of the CMS experiment will face more intense…

Instrumentation and Detectors · Physics 2015-01-21 T. Peltola

In view of the high luminosity phase of the LHC (HL-LHC) to start operation around 2026, a major upgrade of the tracker system for the ATLAS experiment is in preparation. The expected neutron equivalent fluence of up to 2.4 * 1e16 1 MeV…

Instrumentation and Detectors · Physics 2018-02-14 Julien-Christopher Beyer , Alessandro La Rosa , Anna Macchiolo , Natascha Savic , Reem Taibah

In this work we investigated a method to determine time walk in an active silicon pixel sensor prototype using Edge-TCT with infrared laser charge injection. Samples were investigated before and after neutron irradiation to 5e14 neq/cm2.…

‹ Prev 1 2 3 10 Next ›