Ptychography has become prominent at synchrotron facilities worldwide for characterizing biological and material specimens' topological structures and properties at the nanometer or atomic scale, due to its lens - less, highly quantitative…
The torsional vibration of atomic force microscope (AFM) cantilevers is critical for high-sensitivity measurements, yet existing models for width-varying cantilevers often rely on approximations that lead to significant discrepancies with…
Possible light bosonic dark matter interactions with the Standard Model photon have been searched by microwave resonant cavities. In this paper, we demonstrate the cryogenic readout system calibration of a 7.138 GHz copper cavity with a…
We report on the design and implementation of a rotating sample magnetometer (RSM) operating in the variable temperature insert of a cryostat equipped with a high-field magnet. The limited space and the cryogenic temperatures impose the…
Dielectric measurements on insulating materials at cryogenic temperatures can be challenging, depending on the frequency and temperature ranges of interest. We present a technique to study the dielectric properties of bulk dielectrics at…
We propose a novel ultrasonic sensor structure composed of Cantilever arm structure slot dual-micro-ring resonators(DMRR).We present a theoretical analysis of transmission by using the coupled mode theory.The mode field distributions and…
Differentiating signals from the background in micrographs is a critical initial step for cryogenic electron microscopy (cryo-EM), yet it remains laborious due to low signal-to-noise ratio (SNR), the presence of contaminants and densely…
A normal metal - superconductor hybrid single-electron trap with tunable barrier is utilized as a tool for spectrum analysis at the extremely low signal levels, using only well filtered cryogenic microwave background as a photon source in…
We present mechanical measurements performed at low temperatures on cantilever-based microelectro-mechanicalstructures(MEMS) coated with a metallic layer. Two very different coatings are presented in order to illustrate the capabilities of…
For microlensing case angular distances between images or typical astrometric shifts due to microlensing are about $10^{-5}-10^{-6} \mu as$. Such an angular resolution will be reached with the space space--ground interferometer Radioastron.…
Scanning probe microscopes scan and manipulate a sharp tip in the immediate vicinity of a sample surface. The limited bandwidth of the feedback mechanism used for stabilizing the separation between the tip and the sample makes the fragile…
Superconducting circuit testing and materials loss characterization requires robust and reliable methods for the extraction of internal and coupling quality factors of microwave resonators. A common method, imposed by limitations on the…
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Planck LFI Radiometer Chain Assemblies (RCAs) have been calibrated in two dedicated cryogenic facilities. In…
The sensitivity of mechanical resonators to physical quantities such as acceleration, pressure, mass and temperature enables them to underpin sensing and metrology applications. Here, we observe that the resonance frequency of a…
We report the development of a continuous-wave and pulsed X-band electron spin resonance (ESR) spectrometer for the study of spins on ordered surfaces down to cryogenic temperatures. The spectrometer operates in ultra-high vacuum and…
This paper presents a polarization calibration method applied to a microwave polarimeter demonstrator based on a near-infrared (NIR) frequency up-conversion stage that allows both optical correlation and signal detection at a wavelength of…
A force measurement technique has been developed that utilizes a clamped fiber optic element both as a cantilever and as a highly sensitive probe of the static and dynamic displacement of a sample that is mounted near its free end. Light…
Cryogenic environments benefit ion trapping experiments by offering lower motional heating rates, collision energies, and an ultra-high vacuum (UHV) environment for maintaining long ion chains for extended periods of time. Mechanical…
We show that fast technical fluctuations of microwave signals can be strongly suppressed by cryogenic resonators. The experiments were carried out with sapphire resonators cooled to approximately 6 K at frequencies around 11 GHz. Each…
We present a single-quadrature feedback scheme able to overcome the conventional 3 dB limit on parametric squeezing. The method is experimentally demonstrated in a micromechanical system based on a cantilever with a magnetic tip. The…