Related papers: X-ray luminescence computed tomography using a foc…
Scintillation light from gamma ray irradiation in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency.…
Single air-suspended carbon nanotubes (length 2 - 5 microns) exhibit high optical quantum efficiency (7 - 20%) for resonant pumping at low intensities. Under ultrafast excitation, the photoluminescence dramatically saturates for very low…
A simple X-ray imaging system using off-the-shelf electronics and simple reconstruction algorithms aiming a spatial resolution of 1.7 mm ($\sim 3\,\%$ of the detector length) is described in this work. For this, two 100 cm$^2$ Gas Electron…
Based on high-throughput dark-field full-field optical coherence tomography, we designed and built an OCT system that can measure a variety of samples with different scattered light intensities, such as materials with multi-layer…
When light passes through a multimode fiber, two-dimensional random intensity patterns are formed due to the complex interference within the fiber. The extreme sensitivity of speckle patterns to the frequency of light paved the way for…
We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of…
The RefleXion X1 is the first biology-guided radiotherapy (BgRT) system. Its dual 90-degree PET detector collects fewer pair production events compared to a full-ring diagnostic PET system. In the proposed BgRT workflow, a short scan is…
X-ray photon correlation spectroscopy (XPCS) allows for the resolution of dynamic processes within a material across a wide range of length and time scales. X-ray speckle visibility spectroscopy (XSVS) is a related method that uses a single…
X-ray 3D tomography is So far limited to micron resolution because of the large focusing spot of the focused electron beam on the metal target. Here, we proposed a nanofocous X-ray 3D tomography system based on focused electrons from…
Unlike previous works, this open data collection consists of X-ray cone-beam (CB) computed tomography (CT) datasets specifically designed for machine learning applications and high cone-angle artefact reduction. Forty-two walnuts were…
We describe a fast data-driven optical camera, Tpx3Cam, with nanosecond scale timing resolution and 80 Mpixel/sec throughput. After the addition of intensifier, the camera is single photon sensitive with quantum efficiency determined…
The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR…
Computational ghost imaging is a robust and compact system that has drawn wide attentions over the last two decades. Multispectral imaging possesses spatial and spectral resolving abilities, is very useful for surveying scenes and…
We have tested a prototype time-of-flight system based on bulk scintillator block of dimensions $2.5 \times 2.5 \times 200$ cm. Using a calibration scheme similar to the one used in actual collider experiments, we have achieved a resolution…
There is a large body of work that has used the excellent Chandra observations of nearby galaxies with neglible low mass X-ray binary (LMXB) populations. This has culminated in a ``Universal'' X-ray luminosity function (XLF) for high mass…
A dedicated in-vacuum X-ray detector based on the hybrid pixel PILATUS 1M detector has been installed at the four-crystal monochromator beamline of PTB at the electron storage ring BESSY II in Berlin. Due to its windowless operation, the…
Accurate 3D dental imaging is vital for diagnosis and treatment planning, yet CBCT's high radiation dose and cost limit its accessibility. Reconstructing 3D volumes from a single low-dose panoramic X-ray is a promising alternative but…
Non-destructive nano-imaging of the internal structure of solid matter is only feasible using hard X-rays due to their high penetration. The highest resolution images are achieved at synchrotron radiation sources (SRF), offering superior…
We report the development of a laboratory-based Rowland-circle monochromator that incorporates a low poer x-ray (bremsstrahlung) tube source, a spherically-bent crystal analyzer (SBCA), and an energy-resolving solid-state detector. This…
Rapid, comprehensive, and accurate cell phenotyping without compromising viability, is crucial to many important biomedical applications, including stem-cell therapy, drug screening, and liquid biopsy. Typical image cytometry methods…