Related papers: Temperature dependence of plastic scintillators

200 papers

Balloon- and space-borne cosmic-ray experiments employ plastic scintillators read out by silicon photomultipliers (SiPMs) to achieve picosecond-level time resolutions for triggering and particle identification. The performance of these…

Instrumentation and Detectors · Physics 2025-11-14 José Reyes Castillo , Saúl Aguilar Salazar , Diego Mauricio Gomez Coral

The Plastic Scintillator Detector (PSD) is one of the main sub-detectors in the DArk Matter Particle Explorer (DAMPE) project. It will be operated over a large temperature range from -$10$ to $30^{\circ}$C, so the temperature effect of the…

Instrumentation and Detectors · Physics 2016-12-13 Zhao-Min Wang , Yu-Hong Yu , Zhi-Yu Sun , Ke Yue , Duo Yan , Yong-Jie Zhang , Yong Zhou , Fang Fang , Wen-Xue Huang , Jun-Ling Chen

We studied the temperature dependence of the light yield of the linear alkyl benzene (LAB)-based and mesitylene-based liquid scintillators. The light yield increases by 23% for both liquid scintillators when the temperature is lowered from…

Instrumentation and Detectors · Physics 2014-02-28 Xia DongMei , Yu BoXiang , Li XiaoBo , Sun XiLei , Ding YaYun , Zhou Li , Cao Jun , Hu Wei , Ye XingCheng , Chen HaiTao , Ding XueFeng , Du Bing

Plastic scintillators have become increasingly important in particle physics for time-of-flight and calorimetry measurements. Their light yield and the possibility of customizing their geometry make them also attractive for the construction…

Instrumentation and Detectors · Physics 2023-05-29 M. Biassoni , A. Caminata , S. Caprioli , A. Celentano , S. Davini , A. Marini , G. Sobrero

A plastic scintillator bar with dimensions 300 cm x 2.5 cm x 11 cm was exposed to a focused muon beam to study its light yield and timing characteristics as a function of position and angle of incidence. The scintillating light was read out…

Instrumentation and Detectors · Physics 2017-08-07 A. Blondel , D. Breton , A. Dubreuil , A. Khotyantsev , A. Korzenev , J. Maalmi , A. Mefodev , P. Mermod , E. Noah

Highly segmented calorimeters represent a modern trend in experimental particle physics aimed at improving the energy resolution with the particle flow reconstruction. The widely used and cost-effective solution is the structure assembled…

Instrumentation and Detectors · Physics 2025-06-11 M. Chadeeva , A. Stifutkin

Scintillation detector is widely used for the particle detection in the field of particle physics. Particle detectors containing fluorine-19 ($^{19}\mathrm{F}$) are known to have advantages for Weakly Interacting Massive Particles (WIMPs)…

Instrumentation and Detectors · Physics 2022-01-03 Keita Mizukoshi , Takeshi Maeda , Yuuki Nakano , Satoshi Higashino , Kentaro Miuchi

The advent of the silicon photomultiplier has allowed the development of highly segmented calorimeters using plastic scintillator as the active media, with photodetectors embedded in the calorimeter, in dimples in the plastic. To reduce the…

Instrumentation and Detectors · Physics 2024-01-23 B. Kronheim , A. Belloni , T. K. Edberg , S. C. Eno , C. Howe , C. Palmer , C. Papageorgakis , M. Paranjpe , S. Sriram

This study explores the feasibility of using scintillation detectors for muon calorimetry through experiments conducted at CERN's T10 beamline. Results from organic scintillators with varying thicknesses and readout methods, as well as a…

Plastic scintillators detectors (PSDs) have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. Measurement and analysis of energy dependency were performed on a Siemens Mammomat…

Instrumentation and Detectors · Physics 2017-11-06 J. Antunes , J. Machado , L. Peralta , N. Matela

We have performed measurements of scintillation light in liquid neon, observing a signal yield in our detector as high as (3.5 $\pm$ 0.4) photoelectrons/keV. We measure pulse shape discrimination efficiency between electronic and nuclear…

Nuclear Experiment · Physics 2012-08-14 W. H. Lippincott , K. J. Coakley , D. Gastler , E. Kearns , D. N. McKinsey , J. A. Nikkel

The temperature of the working environment is a key factor in determining the properties of semiconductor detectors, and it affects the absolute accuracy and stability of the standard detector. In order to determine the temperature…

Instrumentation and Detectors · Physics 2016-11-22 Si-Ming Guo , Jin-Jie Wu , Jian Zhang , Xu-Fang Li , Cong-Zhan Liu , Shuai Zhang , Cheng-Ze Li , Bin-Bin Huo , Zhen-Yu Liao

Plastic scintillators are widely used in high-energy and medical physics, often for measuring the energy of ionizing radiation. Their main disadvantage is their non-linear response to highly ionizing radiation, called ionization quenching.…

Instrumentation and Detectors · Physics 2021-02-03 Thomas Pöschl , Daniel Greenwald , Martin Jan Losekamm , Stephan Paul

We have characterized two state-of-the-art solid-state photomultipliers, one by SensL, the other by Hamamatsu, coupled to scintillators by Saint-Gobain Crystals in the -25 to 50 degrees C temperature range. At room temperature, the energy…

Instrumentation and Detectors · Physics 2011-03-28 Clarisse Tur , Vladimir Solovyev , Jeremy Flamanc

Plastic scintillators that can discriminate between gamma rays, fast neutrons, and thermal neutrons were synthesized and characterized while considering the balance between processing and performance at the kilogram scale. These trade-offs…

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

It is a familiar fact that the total measured light yield of NaI (Tl) detectors is a nonlinear function of temperature. Here we present new experimental data for the temperature behavior of doped NaI(Tl) scintillators that instead shows a…

Instrumentation and Detectors · Physics 2009-08-05 K. D. Ianakiev , B. S. Alexandrov , P. B. Littlewood , M. C. Browne

The intensity of scintillation light emission from liquid xenon at room temperature was measured. The scintillation light yield at 1 deg. was measured to be 0.64 +/- 0.02 (stat.) +/- 0.06 (sys.) of that at -100 deg. Using the reported light…

The last years have seen the first cryogenic detectors to be proposed for usage on balloon-borne missions. In such missions, the instrument will be exposed to the high radiation environment of the upper atmosphere. This radiation can induce…

Instrumentation and Detectors · Physics 2025-10-23 Merlin Kole , Kasun Wimalasena , Richard Gorby , Torsten Diesel , Zachary Greenberg , Fabian Kislat

High light collection efficiency is an important requirement in any application of scintillation detectors. The purpose of this study is to investigate the possibility for improving this parameter in cryogenic scintillation bolometers,…

Instrumentation and Detectors · Physics 2014-02-11 F. A. Danevich , R. V. Kobychev , V. V. Kobychev , H. Kraus , V. B. Mikhailik , V. M. Mokina