Related papers: Temperature dependence of plastic scintillators
In particle physics, homogeneous calorimeters are used to measure the energy of particles as they interact with the detector material. Although not as precise as trackers or muon detectors, these calorimeters provide valuable insights into…
The fluorescence detection of ultra high energy cosmic rays requires a detailed knowledge of the fluorescence light emission from nitrogen molecules over a wide range of atmospheric parameters, corresponding to altitudes typical of the…
Chromatic calorimetry (CCAL) analyses particle detection by utilizing scintillators with distinct emission wavelengths to measure the longitudinal energy deposition of particle showers in high-energy physics, improving particle…
GaN defect-based quantum emitters show significant potential for quantum information technologies, yet their intrinsic nature is not fully understood. In this work, we present results on the temperature-dependent emission polarization of…
Liquid xenon particle detectors rely on excellent light collection efficiency for their performance. This depends on the high reflectivity of polytetrafluoroethylene (PTFE) at the xenon scintillation wavelength of 178 nm, but the angular…
Silicon nanocrystals are studied by time-resolved fluorescence spectroscopy. After laser excitation the bright and dark exciton ground state levels are populated at random, but subsequently the decay curves reveal a thermalization between…
Hadron calorimeter (HCAL) is an essential sub-detector of the baseline detector system for Circular Electron Positron Collider (CEPC). We plan to build an Analog Hadron CALorimeter (AHCAL) prototype based on the Particle Flow Algorithm…
We present experimental results of characterization of Silicon photomultipliers (SiPM) in a temperature range from 90~mK to 40~K. Two SiPMs, one from ONSEMI and one from Hamamatsu Photonics were tested. Operating voltage ranges, dark count…
The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect…
We report on the first measurement of a temperature dependence of the Casimir-Polder force. This measurement was obtained by positioning a nearly pure 87-Rb Bose-Einstein condensate a few microns from a dielectric substrate and exciting its…
The temperature dependence of conductivity of partially dehydrochlorinated PVC films, containing in their macromolecules chains of polyene-conjugated bonds (PCB) and representing copolymer PVC-Polyacetylene. In samples with excess of some…
Using highly monochromatic synchrotron X-rays in the energy range from 10.5 keV to 100 keV the temperature dependence of nonproportionality and energy resolution of LaBr3 scintillators doped with 5% Ce3+ were studied at 80K, 295K, and 450K.…
Light scattered by amorphous thin-film optical coatings limits the sensitivity of interferometric gravitational-wave detectors. We describe an imaging scatterometer to assess the role that crystal growth during annealing plays in this…
A liquid scintillator (LS) is developed for the Taishan Antineutrino Observatory (TAO), a ton-level neutrino detector to measure the reactor antineutrino spectrum with sub-percent energy resolution by adopting Silicon Photomultipliers…
In recent years there has been considerable interest in developing photonic temperature sensors such as the Fiber Bragg gratings (FBG) as an alternative to resistance thermometry. In this study we examine the thermal response of FBGs over…
The non-linear energy response of the plastic scintillator EJ-260 is measured with the MicroCHANDLER detector, using neutron beams of energy 5 to 27 MeV at the Triangle Universities Nuclear Laboratory. The first and second order Birks'…
We have characterised Water-based Liquid Scintillator (WbLS) using low energy protons, UV-VIS absorbance, and fluorescence spectroscopy. We have also developed and validated a simulation model that describes the behaviour of WbLS in our…
A hybrid dual-readout calorimeter concept, comprising both electromagnetic and hadronic sections, has recently been proposed to meet the performance requirements of experiments at future e$^{+}$e$^{-}$ colliders. The front compartment…
Recent publications have described a method for stand-off optical detection of explosives using resonant infra-red photothermal imaging. This technique uses tuned lasers to selectively heat small particles of explosive lying on a substrate…
The development prospects have been considered of a scintillator-photodiode type detector with improved energy resolution attaining several per cent ($R=1-2%$). The main contributions to the scintielectron detector energy resolution have…